Memory type
The type of the main memory of the drive determines the features of the distribution of information over hardware cells and the physical features of the cells themselves.
—
MLC. Multi Level Cell memory based on multi-level cells, each of which contains several signal levels. MLC memory cells store 2 bits of information. Has optimum indicators of reliability, power consumption and productivity. Until recently, the technology was popular in entry-level and mid-range SSD modules, now it is gradually being replaced by more advanced options in the manner of TLC or 3D MLC.
—
TLC. The evolution of MLC technology. One Flash Memory Triple Level Cell can store 3 bits of information. Such a recording density somewhat increases the likelihood of errors compared to MLC, in addition, TLC memory is considered less durable. A positive feature of the nature of this technology is its affordable cost, and various design tricks can be used to improve reliability in SSDs with TLC memory.
—
3D NAND. In a 3D NAND structure, several layers of memory cells are arranged vertically, and interconnections are organized between them. This provides greater storage capacity without increasing the physical size of the drive and improves memory performance due to shorter connections for each memory cell. In SSD drives, 3D NAND memory can use MLC, TLC or QLC chips - more details
...about them are described in the corresponding help paragraphs.
— 3D MLC NAND. MLC-memory has a multilayer structure — its cells are placed on the board not in one level, but in several "floors". As a result, manufacturers have achieved an increase in storage capacity without a noticeable increase in size. Also, 3D MLC NAND memory is characterized by higher reliability than the original MLC (see the relevant paragraph), at a lower manufacturing cost.
— 3D TLC NAND. "Three-dimensional" modification of the TLC technology (see the relevant paragraph) with the placement of memory cells on the board in several layers. This arrangement allows you to achieve higher capacity with smaller sizes of the drives themselves. In production, such memory is simpler and cheaper than a single-layer one.
— 3D QLC NAND. Quad Level Cell flash type with 4 bits of data in each cell. The technology is designed to make SSDs with large volumes widely available and finally retire traditional HDDs. In the 3D QLC NAND configuration, the memory is built according to a “multi-level” scheme with the placement of cells on the board in several layers. "Three-dimensional" structure reduces the cost of production of memory modules and allows you to increase the volume of drives without compromising their weight and size component.
— 3D XPoint. A fundamentally new type of memory, radically different from traditional NAND. In such drives, memory cells and selectors are located at the intersections of perpendicular rows of conductive tracks. The mechanism for recording information in cells is based on changing the resistance of the material without the use of transistors. 3D XPoint memory is simple and inexpensive to produce, and offers much better speed and durability. The prefix "3D" in the name of the technology says that the cells on the crystal are placed in several layers. The first generation of 3D XPoint received a two-layer structure and was made using a 20-nanometer process technology.Write speed
The highest speed in write mode characterizes the speed with which the module can receive information from a connected computer (or other external device). This speed is limited both by the connection interface (see "Connector"), and by the characteristics of the device of the SSD itself.
Read speed
The highest data exchange rate with a computer (or other external device) that the drive can provide in read mode; in other words —
the highest speed of information output from the drive to an external device. This speed is limited both by the connection interface (see "Connector"), and by the characteristics of the device of the SSD itself. Its values can vary from 100 – 500 MB / s in the slowest models to 3 Gb / s and higher in the most advanced ones.
MTBF
The drive's time between failures is the time that it is able to continuously work without failures and malfunctions; in other words — the operating time, after which there is a high probability of failures, and even failure of the module.
Usually, the characteristics indicate some average time derived from the results of conditional testing. Therefore, the actual value of this parameter may differ from the claimed one in one direction or another; however, in fact, this moment is not particularly significant. The fact is that for modern SSDs, the MTBF is estimated at millions of hours, and 1 million hours corresponds to more than 110 years — while we are talking about pure operating time. So, from a practical point of view, the durability of a drive is often limited by more specific parameters — TBW and DPWD (see below); and the manufacturer's warranty generally does not exceed several years. However, data on the MTBF in hours can also be useful when choosing: other things being equal, more time means more reliability and durability of the SSD as a whole.
Write IOPS
The IOPS provided by the drive in write mode.
The term IOPS refers to the highest number of I / O operations that an SSD module can perform per second, in this case, when writing data. By this indicator, the speed of the drive is often evaluated; however, this is not always true. Firstly, the IOPS values of different manufacturers can be measured in different ways — by the maximum value, by average, by random write, by sequential write, etc. Secondly, the benefits of high IOPS become noticeable only with some specific operations — in in particular, the simultaneous copying of numerous files. In addition, in fact, the speed of the drive may be limited by the system to which it is connected. In light of all this, it is generally acceptable to compare different SSD modules by IOPS, but the real difference in performance is likely not to be as noticeable as the difference in numbers.
As for specific values, for the write mode with IOPS
up to 50K is considered relatively modest,
50 – 100K — medium,
more than 100K — high.
Read IOPS
The IOPS provided by the drive in read mode.
The term IOPS refers to the maximum number of I / O operations that an SSD module can perform per second, in this case, when reading data from it. By this indicator, the speed of the drive is often evaluated; however, this is not always true. Firstly, the IOPS values of different manufacturers can be measured in different ways — by the maximum value, by the average, etc. Secondly, the advantages of high IOPS become noticeable only with some specific operations — in particular, when copying numerous files at the same time. In addition, in fact, the speed of the drive may be limited by the system to which it is connected. In light of all this, it is generally acceptable to compare different SSD modules by IOPS, but the real difference in performance is likely not to be as noticeable as the difference in numbers.
For modern SSDs in read mode, an IOPS value of
less than 50K is considered a very limited indicator, in most models this parameter lies in the range of
50 – 100K, but there are also
higher numbers.
DWPD
The number of full overwrites per day allowed by the design of the drive, in other words, how many times a day the entire drive can be guaranteed to be overwritten without fear of failures.
This parameter describes the overall reliability and durability of the drive. It is similar in meaning to TBW (see the relevant paragraph), one value can even be converted to another, knowing the warranty period: TBW = DWPD*V*T*365, where V is the drive capacity in terabytes, and T is the warranty period in years . However, DWPD is somewhat more specific: it describes not only the total time between failures, but also the limit on the number of rewrites per day; if this limit is exceeded, the drive may fail earlier than specified in the warranty. However, even small DWPD values —
0.5 – 1 time per day, or even
less than 0.5 times a day — often turn out to be sufficient not only for simple everyday use, but even for professional tasks. Higher rates —
1 – 2 times a day or
more — are rare; at the same time, it can be both high-end and low-cost SSD modules.