USA
Catalog   /   Tools & Gardening   /   Measuring instruments   /   Multimeters

Comparison Yato YT-73081 vs Yato YT-73080

Add to comparison
Yato YT-73081
Yato YT-73080
Yato YT-73081Yato YT-73080
Outdated Product
from $7.32
Outdated Product
TOP sellers
Product typemultimetermultimeter
Typedigitaldigital
Measurement types
Measurements
voltage
current
resistance
voltage
current
resistance
Specs
Current typedCdC
Voltage typeconstant / variableconstant / variable
DC voltage minimum200 mV200 mV
DC voltage max.600 V500 V
Measurement accuracy (V⁻)0.5 %
AC voltage max.600 V500 V
DC minimum200 µA2000 µA
DC max.10 A5 A
Impedance minimum200 Ω200 Ω
Impedance max.2 MΩ2 MΩ
Display size45x23 mm
Display count19991999
Display value3 1/23 1/2
Features
Functions
transistor test
diode test
continuity test mode
 
transistor test
diode test
continuity test mode
square wave generator
In box
test probes
test probes
General
Display backlight
Stand
Power sourcebatterybattery
Battery type2xAAA"Crown"
Dimensions155x75x30 mm126x70x24 mm
Weight130 g140 g
Added to E-Catalogmay 2021november 2016

DC voltage max.

The highest DC voltage (see “Voltage type”) that can be effectively measured with this instrument.

Compliance with this parameter is important not only for correct measurements, but also from a safety point of view. Measuring too high voltage can lead to malfunctions of the device, ranging from the operation of emergency protection (and it can take the form of a disposable fuse that requires replacement after operation) and ending with a complete failure and even fire. Therefore, it is impossible to exceed this indicator anyway. Yes, and choosing a device for maximum voltage is worth with a certain margin — at least 10 – 15%: this will give an additional guarantee in case of emergency situations. On the other hand, the margin should not be too large: a high constant voltage threshold can degrade the accuracy of measurements at low voltage, as well as affect the price, dimensions and weight of the device.

Note that most multimeters and other similar devices have several measurement ranges, with different maximum thresholds. So, for a safe measurement of voltage close to the maximum, you need to set the appropriate mode in the settings.

Measurement accuracy (V⁻)

Measurement accuracy provided by the instrument.

Measurement accuracy for multimeters is usually indicated by the smallest error (in percent) that the device is able to provide when measuring direct current. The smaller the number in this paragraph, the higher the accuracy, respectively. At the same time, we emphasize that it is the smallest error (the highest accuracy) that is usually achieved only in a certain measurement range; in other ranges, the accuracy may be lower. For example, if in the range "1 — 10 V" the device gives a maximum deviation of 0.5%, and in the range "10 — 50 V" — 1%, then 0.5% will be indicated in the characteristics. Nevertheless, according to this indicator, it is quite possible to evaluate and compare modern multimeters. So, a device with a lower claimed error, usually, and in general will be more accurate than a model with a similar performance with a larger error.

Data on measurement accuracy in other ranges and modes can be given in the detailed characteristics of the device. However, in fact, this information is required not so often — only for certain specific tasks, where it is fundamentally necessary to know the possible error.

AC voltage max.

The largest alternating voltage (see “Type of voltage”) that can be effectively measured using this model. This parameter is important not only for measurements as such, but also for safe handling of the device: measuring too high voltage will, at best, trigger emergency protection (and it is possible that after that you will have to look for a new fuse to replace the burned one), at worst — to equipment failure or even fire. In addition, for safe measurements, a voltage margin is highly desirable — this is due both to the characteristics of the alternating current and to the possibility of various emergency situations in the network, primarily voltage surges. For example, for 230 V networks, it is desirable to have a device for at least 250 V, and preferably 300 – 310 V; detailed recommendations for other cases can be found in special sources.

Note that most multimeters and other similar devices have several measurement ranges, with different maximum thresholds. So, for a safe measurement of voltage close to the maximum, you need to set the appropriate mode in the settings.

DC minimum

The upper limit of the lower sub-range in which the device can measure direct current (see "Type of current").

The operating ranges of modern multimeters and other measuring instruments are usually divided into subranges. This is done for accuracy and convenience in measurements: the lower the subrange, the smaller values it covers, the higher the measurement accuracy at low current values. The minimum direct current describes exactly the lower range, designed for the weakest current values: for example, if the characteristics in this paragraph indicate 500 μA, this means that the lower subrange allows you to measure currents from 0 to 500 μA.

It is worth choosing according to this indicator taking into account the specifics of the planned application: for example, a device with low rates can be useful for delicate work, such as repairing computers or mobile phones, but for servicing the on-board electrical network of cars, especially old ones, especially high current sensitivity is not required.

DC max.

The highest direct current (see “Type of current”) that the device is able to measure without overloads and related troubles (such as “flying” fuses or even failure).

When choosing for this parameter, it is worth remembering that even at relatively low voltages, the currents can be quite high if the power source provides the appropriate power — for example, a 12 V car battery is quite capable of delivering currents of hundreds of amperes. Actually, compatibility with high direct currents is important primarily for automotive devices; however, the matter is not limited to this.

For safe use, it is desirable to have a certain margin for maximum current. Also, do not forget that before measurements you need to set the appropriate settings.

Functions

- Checking the transistor. The ability to use the device to test transistors, more precisely, the presence of an appropriate mode in the design of the device. Technically, the performance of a transistor can be checked to a certain extent with an ordinary ohmmeter, for this there is an appropriate technique. Nevertheless, it is much easier to use a special mode - just connect the transistor to the multimeter in an appropriate way, and the device will automatically give data on the health or malfunction of the part (and sometimes additional characteristics for it). Most often, for such measurements, there is a special block on the case with a set of sockets for transistor outputs (with separate sets of sockets for pnp and npn types).

- Checking the diode. The presence of a special diode test mode in the design of the multimeter. The principle of a diode is to allow electric power to flow in only one direction; therefore, the serviceability of such a part itself can be determined without a special mode, for example, in the mode of a conventional ohmmeter, “continuity” of the circuit (see below), or in some other ways. However, special mode is often more convenient - both due to the simplicity of the procedure itself, and due to the fact that many devices in this mode are also able to measure the forward voltage drop across the diode (the lowest voltage required to pass power in the forward direction...).

— "Continuity" of the chain. Possibility of operation of the device in the "continuity" mode of the circuit - checking the presence of contact between two selected points. This mode differs from the usual check with an ohmmeter in that the presence of a contact is accompanied by an audible signal (hence the name). Such a signal saves the user from having to look at the scale of the device every time to clarify the presence or absence of contact, and this greatly speeds up the work and can be very useful if you need to “ring out” many sections at once.

- Meander generator. Ability to operate the device in the meander generation mode - a signal with a rectangular pulse shape and a duty cycle (see above) at level 2. The graph of such a signal looks like a set of rectangular peaks and dips of the same length. Meander is a regular signal format for modern digital technology; a signal of this type, generated by a multimeter, is used to test microcircuits, logic elements, amplifiers and other similar elements and circuits (for performance, signal flow, etc.).

Non-contact detection (NCV). Ability to detect live parts without direct contact with them. This method of detection is as safe as possible, besides, it allows you to find elements hidden from the eye: for example, using a device with this function, you can detect wiring in walls and determine places where you can drill without fear of damaging the wire.

True RMS. Ability to measure with the True RMS device - the true RMS value of the strength of the alternating power (see "Type of power"). The strength of the alternating power is determined not by the actual value (it will be different at each moment of time), and not by the maximum amplitude (after all, the maximum values also occur only at certain points in time), but by the root mean square. At the same time, in devices that do not support True RMS, this value is displayed as follows: the alternating power is rectified, its value is determined and multiplied by a factor of 1.1 (this is due to the mathematical features of the measurements). However, this method is only suitable for an ideal sinusoid; with a distorted signal, it gives a noticeable, and often even unacceptably high error. Distortions are found in almost any AC network, which can lead to serious measurement errors and subsequent problems (for example, to the selection of too “weak” automatic fuse). True RMS technology takes into account all these features: devices bearing this marking are able to accurately measure AC RMS power, regardless of how its shape corresponds to a perfect sine wave.

- Auto-selection of the measuring range. A function that allows the device to automatically select the optimal measurement range - so that the result is displayed on the screen as accurately as possible. This function is found only in digital instruments (see "Type"). Note that when using it, the user will still have to set certain basic settings - for example, “direct power, power, milliamps” or “alternating power, voltage, volts”. However, the device will perform a more precise setting itself: for example, to measure voltage in hundreds of volts, the range 0 - 1000 V can be used with an accuracy of 5 V, and when a 1.5 V battery is connected, the device will automatically switch to the range 0 - 12 V and display the result is already accurate to tenths of a volt. At the same time, the design may also provide for a completely manual measurement mode, with a range selection at the request of the user, however, the presence of such a mode will not hurt to clarify separately.

- Auto power off. The function of automatically switching off the Meter after a period of inactivity helps to conserve the charge of the used batteries.

Display backlight

The presence of a backlight in the display of the device.

This function allows you to read the display regardless of lighting conditions — at dusk and even in total darkness. If there is not enough external light, just turn on the backlight, and the readings will be perfectly visible.

Battery type

The type of battery used in the device. Note that the term “battery” in this case refers to all types of autonomous power sources - both rechargeable and disposable. These include: AAA, AA, C, “Krona”, A23, CR2032, etc.

- AA. Classic AA batteries, one of the most popular sizes these days. Available both in the form of disposable cells and in the form of rechargeable batteries; sold almost everywhere. The number of such batteries required to power a multimeter can be from 1 to 8, depending on the features of the device.

- AAA. “Mini-finger” or “little finger” batteries, similar to the AA batteries described above, but having reduced dimensions (and, accordingly, less power and capacity). However, given that many multimeters are also quite compact and their power consumption is low, this option is found in measuring instruments even more often than AA. The number of such elements in this case is usually from 1 to 4.

- “6LR61”. The batteries have a characteristic rectangular shape with a voltage of 9 V and a pair of contacts on one of the ends. High voltage contributes to the accuracy of measurements and allows even quite “gluttonous” models to use only one battery; so this option is quite popular in multimeters. Note that most often “Kronas”...are produced in the form of disposable cells, but if desired, you can also find batteries of this size.

- 6LR61 and AAA. Powered simultaneously from the two types of batteries described above. As a rule, each of these power sources is responsible for its own part of the functionality (for example, AAA for resistance measurements, Krona for testing transistors), and in the absence of one of the sources, only the capabilities directly related to it are unavailable. However, in general, such a combination is not particularly convenient and practical, which is why it is rare.

— Krona and AA. An option completely similar to the “6LR61 + AAA” described above - except that in this case, instead of “pinky” batteries, AA batteries are used. Also not popular.

— C. Cylindrical 1.5-volt elements. Available in two types - accumulators and batteries; similar in length to AA (50 mm), but almost twice as thick - 26 mm instead of 14 mm. As a result, they provide higher capacity and power supply, but due to their large size they are used mainly in advanced desktop devices. Moreover, many of these devices have an insulation test function, and the number of C batteries in them can be from 8 to 12 - this is necessary to create the high voltages used for such testing.

- A23. Cylindrical cells characterized by high voltage - 12 V, despite the fact that the size of such batteries is only 29 mm in length and 10 mm in size. Most often they are disposable batteries. In general, they are poorly distributed, which is why they are used relatively rarely in measuring instruments.

— LR44 / SR44. Miniature 1.5-volt batteries in the form of “tablets” with a size of 11.6 mm and a thickness of 5.4 mm. They are made only for disposable use; At the same time, simple and inexpensive alkaline batteries are marked with the “LR44” index, and more expensive and advanced silver-oxide batteries with the “SR44” index. In multimeters, as a rule, you can use both one and the other. In any case, due to their small size, the power and capacity of all such batteries is small, so they are used mainly in miniature devices - not designed for serious tasks and not having enough space in the case for more solid batteries.

- CR2032. Miniature button batteries with a voltage of 3 V, having a size of 20 mm and a thickness of 3.2 mm. Like LR44 / SR44, they are found mainly in small devices - incl. very miniature, made in the form factor of a pen or even a key fob; however, due to their larger sizes, they provide more advanced power characteristics, which is why they are noticeably more common. CR2032 elements are made only disposable.

— 18650. Removable lithium-ion batteries are cylindrical, 65 mm long and 18 mm in size. With an operating voltage of 3.7 V, they can also have a fairly high capacity. However, for a number of reasons, this option is not popular - it can be found in some advanced devices.

— Branded battery. Batteries created specifically for specific devices (or series of devices) and not related to standard sizes; often made non-removable. Such batteries can have more advanced characteristics than replaceable batteries, and they eliminate additional expenses - you do not need to regularly buy batteries (or a separate battery with a charger), it is enough to charge the existing power source from time to time. On the other hand, when the charge is depleted, such a battery cannot be quickly replaced with a fresh one - the only option is charging, and this requires an outlet and takes time, sometimes quite considerable. As a result, this method of nutrition has not become particularly widespread.
Yato YT-73080 often compared