Comparison Kingston UV500 SUV500/240G 240 GB vs AMD Radeon R5 R5SL240G 240 GB

Add to comparison
Kingston UV500 SUV500/240G 240 GB
AMD Radeon R5 R5SL240G 240 GB
Kingston UV500 SUV500/240G 240 GBAMD Radeon R5 R5SL240G 240 GB
Compare prices 1Outdated Product
TOP sellers
Placementinternalinternal
Size240 GB240 GB
Form factor2.5"2.5"
InterfaceSATA 3SATA 3
Technical specs
ControllerMarvell DeanSilicon Motion SM2258
Memory type3D TLC NAND3D TLC NAND
Write speed500 MB/s420 MB/s
Read speed520 MB/s520 MB/s
MTBF1 m h1.5 m h
Write IOPS25 K56 K
Read IOPS79 K67 K
TBW100 TB
DWPD0.2 times/day
Manufacturer's warranty5 years3 years
General
TRIM
Data encryption
Size100x70x7 mm100x70x7 mm
Weight41 g
Added to E-Catalogmay 2018february 2018

Controller

Model of the controller installed in the SSD.

The controller is a control circuit, which, in fact, ensures the exchange of information between the memory cells and the computer to which the drive is connected. The capabilities of a particular SSD module (in particular, read and write speed) largely depend on this particular scheme. Knowing the controller model, you can find detailed data on it and evaluate the capabilities of the drive. For simple everyday use, this information is usually not needed, but for professionals and enthusiasts (modders, overclockers) it can come in handy.

Nowadays, high-end controllers are produced mainly under such brands: InnoGrit, Maxio, Phison, Realtek, Silicon Motion, Samsung.

Write speed

The highest speed in write mode characterizes the speed with which the module can receive information from a connected computer (or other external device). This speed is limited both by the connection interface (see "Connector"), and by the characteristics of the device of the SSD itself.

MTBF

The drive's time between failures is the time that it is able to continuously work without failures and malfunctions; in other words — the operating time, after which there is a high probability of failures, and even failure of the module.

Usually, the characteristics indicate some average time derived from the results of conditional testing. Therefore, the actual value of this parameter may differ from the claimed one in one direction or another; however, in fact, this moment is not particularly significant. The fact is that for modern SSDs, the MTBF is estimated at millions of hours, and 1 million hours corresponds to more than 110 years — while we are talking about pure operating time. So, from a practical point of view, the durability of a drive is often limited by more specific parameters — TBW and DPWD (see below); and the manufacturer's warranty generally does not exceed several years. However, data on the MTBF in hours can also be useful when choosing: other things being equal, more time means more reliability and durability of the SSD as a whole.

Write IOPS

The IOPS provided by the drive in write mode.

The term IOPS refers to the highest number of I / O operations that an SSD module can perform per second, in this case, when writing data. By this indicator, the speed of the drive is often evaluated; however, this is not always true. Firstly, the IOPS values of different manufacturers can be measured in different ways — by the maximum value, by average, by random write, by sequential write, etc. Secondly, the benefits of high IOPS become noticeable only with some specific operations — in in particular, the simultaneous copying of numerous files. In addition, in fact, the speed of the drive may be limited by the system to which it is connected. In light of all this, it is generally acceptable to compare different SSD modules by IOPS, but the real difference in performance is likely not to be as noticeable as the difference in numbers.

As for specific values, for the write mode with IOPS up to 50K is considered relatively modest, 50 – 100K — medium, more than 100K — high.

Read IOPS

The IOPS provided by the drive in read mode.

The term IOPS refers to the maximum number of I / O operations that an SSD module can perform per second, in this case, when reading data from it. By this indicator, the speed of the drive is often evaluated; however, this is not always true. Firstly, the IOPS values of different manufacturers can be measured in different ways — by the maximum value, by the average, etc. Secondly, the advantages of high IOPS become noticeable only with some specific operations — in particular, when copying numerous files at the same time. In addition, in fact, the speed of the drive may be limited by the system to which it is connected. In light of all this, it is generally acceptable to compare different SSD modules by IOPS, but the real difference in performance is likely not to be as noticeable as the difference in numbers.

For modern SSDs in read mode, an IOPS value of less than 50K is considered a very limited indicator, in most models this parameter lies in the range of 50 – 100K, but there are also higher numbers.

TBW

The abbreviation TBW stands for drive time between failures, expressed in terabytes. In other words, this is the total amount of information that is guaranteed to be written (rewritten) to this module. This metric measures the overall reliability and lifespan of a drive—the higher the TBW, the longer the device will last, all other things being equal.

Note that knowing the TBW and the warranty period, you can calculate the number of rewrites per day (DWPD, see the relevant paragraph), if the manufacturer did not specify these data. To do this, use the formula: DWPD = TBW / (V * T * 365), where V is the drive capacity in terabytes, T is the warranty period (years). As for specific numbers, there are a lot of drives on the market with a relatively low TBW — up to 100 TB ; even these values are often sufficient for everyday use for a considerable amount of time. However, models with TBW at the level of 100 – 500 TB are more common. Values of 500 – 1000 TB can be classified as "above average", and in the most reliable solutions this figure is even higher.

DWPD

The number of full overwrites per day allowed by the design of the drive, in other words, how many times a day the entire drive can be guaranteed to be overwritten without fear of failures.

This parameter describes the overall reliability and durability of the drive. It is similar in meaning to TBW (see the relevant paragraph), one value can even be converted to another, knowing the warranty period: TBW = DWPD*V*T*365, where V is the drive capacity in terabytes, and T is the warranty period in years . However, DWPD is somewhat more specific: it describes not only the total time between failures, but also the limit on the number of rewrites per day; if this limit is exceeded, the drive may fail earlier than specified in the warranty. However, even small DWPD values — 0.5 – 1 time per day, or even less than 0.5 times a day — often turn out to be sufficient not only for simple everyday use, but even for professional tasks. Higher rates — 1 – 2 times a day or more — are rare; at the same time, it can be both high-end and low-cost SSD modules.

Manufacturer's warranty

Manufacturer's warranty provided for this model.

In fact, this is the minimum service life promised by the manufacturer, subject to the rules of operation. Most often, the actual service life of the device is much longer than the guaranteed one. However, keep in mind that the warranty often includes additional terms, such as “[so many years] or until the TBW is exhausted” (for more on TBW, see above).

Specific warranty periods may vary even for similar drives from the same manufacturer. The most popular options are 3 years and 5 years, however, there are other figures — up to 10 years in the most expensive and high-end models.

TRIM

Module support for the TRIM command.

A feature of the operation of SSD modules is that when deleting data in the normal mode (without using TRIM), changes are made only to the “table of contents” of the drive: certain cells are marked as empty and ready for new information to be written. However, the old information is not deleted from them, and when writing new data, you actually have to overwrite it — this significantly slows down the speed of work. The TRIM command is designed to correct the situation: when it arrives, the drive controller checks if the cells marked as empty are empty and cleans them if necessary.

Of course, this function must be supported not only by the drive, but also by the system, however, the ability to work with TRIM is built into most popular modern operating systems.
Kingston UV500 often compared
AMD Radeon R5 often compared