Tank shape
The shape of the water heater.
The traditional options are
cylindrical and
rectangular, but nowadays there are more specific options —
flat cases,
slim cylindrical devices. Here are the features of each of these options:
— Cylindrical. This form is traditional for storage water heaters. It is because with the same total volume, less material is needed for a cylindrical tank than for a rectangular one; and in production, such tanks are simple and cheap, which allows them to be used in water heaters of any price category. The disadvantages of this form include, first of all, some bulkiness in comparison with other options.
— Rectangular. The case is rectangular in shape, with pronounced front and side faces; the corners can be both sharply defined and rounded. It is the traditional form for instant water heaters, primarily gas, but it can be found in a fairly large number of storage models. Accordingly, the features of a rectangular case will be different — depending on the type of heater. So, in instant water heaters, the “rectangle” is simply one of the most convenient options in terms of the overall layout. But in storage water heaters, this shape differs from the flat one (see below) only with a slightly greater thickness and, in some cases, pronounced angles.
— Flat. A variant found mainly in s
...torage electric heaters. Such devices look as if the classic cylindrical body was flattened at the back and front, reducing its thickness by increasing the width (and sometimes height). Thus, such a boiler does not protrude as much in front of the wall as a cylindrical one; in some cases, this point may be fundamental — for example, when installed in a bathroom, where a cylindrical device would hang over the toilet bowl, creating discomfort.
— Slim. A variety of cylindrical cases are characterized by a reduced diameter. In other words, boilers from this category are also round, but with the same volume, they have a noticeably smaller width and thickness than traditional cylindrical ones. In cramped conditions, this can be very useful. However, it must be borne in mind that the price for reducing the diameter is an increase in height.Magnesium anode
Magnesium anode is used in storage heaters (see type). It is an additional means of protecting the tank and heating elements from corrosion. Due to its special electrochemical properties, magnesium significantly slows down the oxidation of other metal parts that come into contact with water. Note that the magnesium anode has a limited service life. It needs to be changed every 5-7 years.
Heating elements
The number of heating elements provided in the design of the water heater. In this case, it is the total number of elements that are taken into account, regardless of whether they belong to the same type or different ones: for example, 2 heat exchangers and 1 heating element are considered as 3 elements.
All gas models (see "Energy source") have only one heating element — this is quite enough for efficient operation. In
combined devices (see ibid.), on the contrary, there are several heating elements by definition (at least two — a heat exchanger and an electric one). In electric and indirect water heaters, the options may be different.
The meaning of several heaters of the same type is primarily to increase the heating efficiency. For example, in an instant (see "Type") electrical water heater, in this way, it is possible to increase the working length — the distance that water passes inside the device from inlet to outlet; by increasing the working length, the water is heated longer. In storage electric models, several heaters provide more uniform heating of the water, and in indirect ones, they allow more heat to be taken away. In addition, in indirect devices, heat exchangers can differ in the source of heating: for example, one can work from a heating boiler, the second from a solar collector.
Also, note that duplication of heating elements can also be used as protection against failures: if one of them
...fails, the heating efficiency decreases, but the device remains operational. However, this possibility is not available in all models with several heaters, its presence should be clarified separately.Safety systems
The safety of water heaters can be carried out by such functions as
overheat protection frost protection,
dry heating protection,
surge protection,
electrical protection (RCD),
anti-legionella,
gas control and
draft sensor. More about them:
— Overheat protection. Water heater safety system that automatically turns off the power supply or gas supply (depending on the type) when the heating element reaches a critical temperature. It avoids overheating and the troubles associated with it, ranging from heater failure to fire.
— Frost protection. Function to prevent freezing of water in the circuits, tank and/or heat exchanger of the water heater. It will be useful when the device is installed in a room with a low temperature and works with long breaks. Frozen water expands, which can damage the device; to avoid this, the frost protection monitors the temperature of the water in the device and turns on the heating when this temperature drops to a critical level.
— Dry heating protection. A safety system that prevents the heater from being switched on without the presence of water in it. Since the heating element does not transfer heat to the water when turned on, it heats up very q
...uickly and, in a short time, reaches a high temperature that can lead to damage to the heater and even to a fire. The presence of protection against switching on without water allows you to avoid such unpleasant consequences.
— Voltage surge protection. System for protecting the heater from power surges. Electronically controlled models are usually equipped with such protection (see Control) since it is the control electronics that are most sensitive to problems with the power supply. Note that the capabilities of such systems are noticeably more modest than those of specialized stabilizers or protective systems: the “hardware” of a water heater can smooth out relatively weak power surges, but in case of serious failures, it will most likely simply turn off the device to avoid damage. However, this feature will be useful; except that in very unstable electrical grids, prone to frequent fluctuations, such a heater may require an external stabilizer.
— Electrical protection (RCD). Built directly into the heater, the RCD is a residual current device. Such a device is primarily intended to protect people from electric shock — for example, if the insulation is damaged and electricity leaks into the case or water. When a person comes into contact with this electricity, a so-called leakage current occurs. The RCD reacts to it and almost instantly turns off the power to the boiler, preventing electric shock.
Note that such safety devices are standardly installed directly in switchboards. However, the presence of an RCD in the water heater provides additional security. Naturally, such equipment is found mainly in electric models.
— Safety valve. A safety system that prevents a critical increase in water pressure in the heater. Usually, this protection is based on a safety valve that opens when a certain pressure level is reached and drains excess water, avoiding damage to the heater.
— Gas control. Gas heater safety system that automatically shuts off the gas supply in the event of a burner flame failure. It avoids filling the room with gas and possible unpleasant, and even tragic consequences. Resuming the gas supply after the protection is triggered must be done manually.
— Draft sensor. A sensor that monitors the presence of draft in the flue of a gas water heater. This function is especially important for models with open combustion chambers: in the absence of a draft, combustion products will fill the room where the heater is located. And this, in turn, can lead to a deterioration in people's well-being, health problems and even deaths. To avoid such consequences, this sensor, when detecting problems with the draft, turns off the gas supply and issues a warning about the problem. However, such equipment can also be found in models with closed combustion chambers. In them, the draft sensor performs mainly a diagnostic function, allowing you to determine what interferes with the normal operation of the burner.
— Anti-legionella. A function that prevents the growth of pathogenic bacteria in the tank and water heater circuits. Some types of such bacteria can live and multiply in fairly hot water — up to 60 °C. To avoid this, the anti-legionella system monitors the temperature of the water in the tank and periodically raises it to a level of about 65 °C. The specific methods of operation of such systems can be different: for example, some work strictly according to a set schedule (for example, once every two weeks), others turn on additional heating only if for some period (for example, a month) the water has not been heated to sufficiently high temperatures.Tank manufacturer's warranty
The warranty period declared by the manufacturer for the storage water heater tank (see “Type”).
This parameter is important for the reasons of maintenance terms. The tank is the most complex element: other parts of the water heater are relatively easy to repair and change, and if there is a problem with the tank, it is often easier to replace the entire boiler. In the most advanced models, the warranty on the tank can be 10 years or more.