USA
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   Solar Panels

Comparison JA Solar JAM72S20-460/MR 460 W vs Leapton LP182x182-M-60-MH 460W 460 W

Add to comparison
JA Solar JAM72S20-460/MR 460 W
Leapton LP182x182-M-60-MH 460W 460 W
JA Solar JAM72S20-460/MR 460 WLeapton LP182x182-M-60-MH 460W 460 W
Outdated ProductOutdated Product
TOP sellers
Main
Half-Сell
Featuresstationarystationary
Typemonocrystallinemonocrystalline
Specs (STC)
Power (Pmax)460 W460 W
Nominal voltage (Vmp)42.13 В35.2 В
Nominal power (Imp)10.92 А13.08 А
Open-circuit voltage (Voc)50.01 В41.8 В
Short circuit current (Isc)11.45 А13.78 А
Efficiency20.7 %21.25 %
Specs (NOCT)
Power (Pmax)348 W339 W
Rated voltage (Vmp)39.68 V32.74 V
Rated current (Imp)8.76 А10.35 А
Open circuit voltage (Voc)47.38 V39.08 V
Short circuit current (Isc)9.33 А10.88 А
Efficiency15.66 %
Features
MC4 connector
WaterproofIP68IP68
Operating temperature-40 °C ~ +85 °C-40 °C ~ +85 °C
General
Number of cells144 (6x24)
120 (60х2) /11BB/
Dimensions2112x1052x35 mm1134x1909x30 mm
Weight24.5 kg23.5 kg
Added to E-Catalogjanuary 2023november 2022

Specs (STC)

Standard Test Conditions (STC) are standard test conditions that reflect the operation of a solar panel under ideal conditions. As part of the tests, the weather of a clear sunny day with an air temperature of +25 °C, no wind, solar intensity of 1000 W/m² and an emission spectrum relative to air mass of 1.5 is simulated. The surface of the solar cell must be placed strictly perpendicular to the rays from the celestial body. Note that in real operation of the solar panel, such conditions are extremely rare. However, in general, the characteristics of the STC allow us to evaluate the "passport" parameters of the energy storage device.

Nominal voltage (Vmp)

The value on the voltmeter when testing the solar panel at the nominal power level according to the STC method. The Vmp parameter is measured in volts. It stands for Voltage at Maximum Power. Allows you to determine for which type of batteries the panel is provided - for 12 V or for 24 V.

Nominal power (Imp)

Ammeter reading during solar panel testing under STC conditions. The value of the rated current Imp (Current at Maximum Power) is measured in amperes.

Open-circuit voltage (Voc)

The voltage generated by the solar battery in idle mode, that is, without connecting the load. Behind the abbreviation Voc stands for Voltage Open Circuit.

Short circuit current (Isc)

The current value under the condition of zero voltage (Short Circuit Current).

Efficiency

Percentage of the maximum solar panel power to the incident radiation power produced. The efficiency parameter allows you to determine how efficiently the panel PV module converts solar energy into direct electric current.

Specs (NOCT)

The characteristics of NOCT (Nominal Operating Cell Temperature) reflect more realistic operating conditions for solar panels. Testing according to this method is carried out at a lighting intensity of 800 W/m², an air temperature of +20 °C and a wind speed of 1 m/s. The solar battery is placed at an angle of 45° relative to the incident light rays with a south orientation. The temperature of the panel surface in this case reaches +40 - 45 °С.

Power (Pmax)

The amount of electricity in watts that a solar panel produces in one hour in tests according to the NOCT method. The panel must provide the declared number of watts during normal operation.

Rated voltage (Vmp)

The value on the voltmeter when testing the solar battery at the nominal power level according to the NOCT method. The Vmp parameter is measured in volts. It stands for Voltage at Maximum Power.
Leapton LP182x182-M-60-MH 460W often compared