Comparison Cooper&Hunter Majesty CH-S12FTXAM 35 m² vs Cooper&Hunter Supreme Continental CH-S12FTXAL2 35 m²

Add to comparison
Cooper&Hunter Majesty CH-S12FTXAM 35 m²
Cooper&Hunter Supreme Continental CH-S12FTXAL2 35 m²
Cooper&Hunter Majesty CH-S12FTXAM 35 m²Cooper&Hunter Supreme Continental CH-S12FTXAL2 35 m²
Expecting restockOutdated Product
TOP sellers
Typesplit systemsplit system
Installationwallwall
Nominal capacity BTU1200012000
In box
indoor unit
outdoor unit
indoor unit
outdoor unit
Performance
Operating modescooling/heating/dehumidification/ventilationcooling/heating/dehumidification/ventilation
Recommended room area35 m²35 m²
Power consumption (cooling/heating)989/977 W880/950 W
Cooling capacity3510 W3500 W
Heating capacity3810 W3810 W
Air flow680 m³/h680 m³/h
Dehumidification1.4 L/h1.4 L/h
Noise level (max/min)41/19 dB43/19 dB
Efficiency
Cooling EER3.55
Heating COP3.89
Seasonal cooling SEER7.58.5
Seasonal heating SCOP5.25.4
Energy efficiency EER (cooling)A
Energy efficiency COP (heating)A
Energy efficiency SEER (cooling)A+++A+++
Energy efficiency SCOP (heating)A+++A+++
Features
Functions
inverter
automode
timer
night mode
auto restart
ionizer
vertical blinds drive
emergency heating /+8°С/
self-cleaning
self-diagnosis
control via smartphone
I Feel (remote with temperature sensor)
inverter
automode
timer
night mode
auto restart
ionizer
vertical blinds drive
emergency heating
self-cleaning
self-diagnosis
control via smartphone
I Feel (remote with temperature sensor)
Specs
Displayhiddenhidden
Refrigerant typeR32R32
Maximum height difference between units10 m10 m
Maximum pipe length15 m20 m
Min. T for cooling mode-15 °C-15 °C
Maximum T for cooling mode50 °C43 °C
Min. T for heating mode-25 °C-25 °C
Filters
plasma (electrostatic)
fine cleaning
 
UV lamp
 
 
 
 
plasma (electrostatic)
 
catechin
UV lamp
formaldehyde
with silver ions, with vitamin C
against ticks
chitinous
General specs
Indoor unit dimensions (WxHxD)837х293х200 mm865x290x210 mm
Dimensions of window/outdoor unit (WxHxD)732х555х330 mm802x555x350 mm
Indoor unit weight9.5 kg10.5 kg
Outdoor unit weight28 kg29 kg
Added to E-Catalogseptember 2023august 2023

Power consumption (cooling/heating)

Power consumption of the air conditioner in cooling and heating mode; for models without a heating mode, only one number is given. This parameter should not be confused with the effective capacity of the air conditioner. Effective capacity is the amount of heat that the unit can "pump" into the environment or the room. This item also indicates the amount of electricity consumed by the device from the network.

In all air conditioners, the power consumption is several times lower than the effective capacity. It is due to the peculiarities of the operation of such units. At the same time, devices with the same efficiency may differ in power consumption. In such cases, the more economical models usually cost more, but with continued use, the difference can quickly pay off with less electricity consumption.

Also, two points related to electrical engineering depend on this nuance. Firstly, power consumption affects power requirements: models up to 3 – 3.5 kW can be connected to a regular outlet, while higher power consumption requires a three-phase connection (see below). Secondly, the power consumption is needed to calculate the load on the mains and the necessary parameters of additional equipment: stabilizers, emergency generators, uninterruptible power supplies, etc.

Cooling capacity

The heat output of the air conditioner when operating in cooling mode, in other words, the amount of heat energy that the unit can transfer from the room to the external environment when operating in this mode.

In general, cooling capacityup to 2 kW for modern air conditioners is considered very modest, 2–3 kW is low, 3–4 kW is medium, 4–6 kW is above average, and in the heaviest and most productive models this figure can be 6–8 kW and even more. Also, the conventional unit BTU can be used to denote capacity; in our catalogue, 1 BTU corresponds approximately to 0.293 W, however, for the convenience of choice, some deviations are allowed: for example, the 7000 BTU category includes units with power from 1.8 to 2.3 kW. Also on sale you can find air conditioners for 9000, 12000, 18000, 24000 BTU and more.

As for the choice for this indicator, the simplest formula is as follows: at least 100 W or 1/3 BTU of thermal power should fall on 1 m2 of the area of the room. Thus, to estimate the maximum area served, the power in watts should be divided by 100, and the power in...BTU should be multiplied by three. However, all these calculations are relevant only for standard residential/office premises with a ceiling height of about 2.5-3 m. For other conditions, you need to use a more complex formula, which is the sum of three parameters: 1) Q1 - the heat gain of the room itself, calculated by multiplying the area of the room by the height of the ceilings and the heat transfer coefficient (it ranges from 30 to 40 W, depending on the conditions); 2) Q2 - heat gain from operating equipment (on average, a third of the total power of all electrical appliances); 3) Q3 - heat gain from each person (from 100 W for sedentary work to 300 W for heavy physical exertion). More detailed recommendations regarding such calculations can be found in special sources.

A special case is represented by separately sold outdoor units of air conditioners (see "In box"). In this case, the capacity in cooling mode is the highest heating capacity of the indoor unit (in the same mode, of course) that can be connected to this outdoor unit. For multi split systems, respectively, the total indicator of all indoor units is taken into account.

Noise level (max/min)

The maximum and minimum level of noise produced by the air conditioner during operation; for split and multi split systems (see "Type"), by default, it is indicated for the indoor unit, and the data for the outdoor unit can be specified in the notes.

The noise level is indicated in decibels; this is a non-linear unit, so it is easiest to evaluate this parameter using comparative tables — they can be found in special sources. Here we note that, according to sanitary standards, the maximum level of constant noise for residential premises is 40 dB during the day and 30 dB at night; for offices, this figure is 50 dB, and in industrial premises higher volume levels may be allowed. So it is worth choosing an air conditioner according to this indicator, taking into account where and how it is planned to use it.

As for specific numbers, among the quietest modern air conditioners, there are models with a minimum performance of 23 – 24 dB, 22 – 21 dB, and sometimes even 20 dB or less. However, units at 31 – 31 dB and 33 – 34 dB are not uncommon; such loudness, usually, does not create discomfort in the daytime, but at night it is no longer desirable. However, in some cases, a louder air conditioner may be the best choice: noise reduction affects the cost, sometimes quite noticeably, and if the device...is not planned to be turned on at night, you can not overpay for additional noise reduction.

Cooling EER

Cooling factor EER provided by the air conditioner. It is calculated as the ratio of the useful operating power of the air conditioner in cooling mode to the electricity consumption. For example, a device that delivers 6 kW of operating power in cooling mode and consumes 2 kW will have an EER 6/2 = 3.

The higher this indicator, the more economical the air conditioner is and the higher its cooling energy efficiency class (see below). Each class has its clear requirements for EER.

It is worth noting that this indicator is considered not very reliable, and in the European Union another coefficient has been introduced that is closer to practice — SEER. See Energy efficiency SEER (cooling) for more details.

Heating COP

The heating coefficient COP provided by the air conditioner. It is calculated as the ratio of the heat output of the air conditioner in heating mode to the electricity consumption. For example, if a device consumes 2 kW and produces 5 kW of thermal power, then the COP will be 5/2 = 2.5.

The higher this indicator, the more economical the air conditioner is and the higher its energy efficiency class when heating (see below). Each class has its own clear COP requirements.

Note that COP values are usually higher than the values of another important coefficient — EER (see above). It is due to the technical features of the air conditioners.

It is also worth mentioning that since 2013, a more advanced and closer-to-practice coefficient, SCOP, has been put into use in Europe. See "Energy efficiency SCOP (heating)" for more details.

Seasonal cooling SEER

The seasonal SEER cooling factor provided by the air conditioner.

The meaning of this parameter is similar to the cooling coefficient — EER (see above): we are talking about the ratio of useful power to spend, and the higher the coefficient, the more efficient the device is. The difference between these parameters lies in the measurement method: EER is measured for strictly standard conditions (outside temperature +35 °C, workload 100%), while SEER is closer to reality — it takes into account seasonal temperature fluctuations (for Europe) and some other specific points, such as the increased efficiency of inverter compressors. Therefore, since 2013, it is customary to use SEER as the main parameter in the EU; this parameter was also adopted for air conditioners supplied to other countries with a similar climate.

Seasonal heating SCOP

Seasonal heating coefficient SCOP provided by the air conditioner.

Like the COP (see above), this parameter describes the overall efficiency of the air conditioner in heating operation and is calculated by the formula: thermal (useful) power divided by electricity consumption. The higher the coefficient, the more efficient the device, respectively. And the difference between COP and SCOP is that COP is measured under strictly standard conditions (outside temperature +7 °C, full workload), and SCOP takes into account seasonal temperature fluctuations (for Europe), changes in air conditioner operating modes, the presence of an inverter and some other options. Thanks to this, SCOP is closer to real indicators, and since 2013 this coefficient has been taken as the main one in the territory of the European Union. However, this parameter is also used for air conditioners supplied to other countries with a similar climate.

Energy efficiency EER (cooling)

The general energy efficiency class that the air conditioner complies with in cooling mode.

This parameter is indicated by letters from A (highest efficiency) and beyond. It is directly related to the value of the EER factor (see "Cooling EER"): each energy efficiency class corresponds to a certain range of factors (for example, B — from 3.0 to 3.2). Specific coefficient values for each class can be found in special tables; here we note that more efficient air conditioners are more expensive, but this difference can pay off due to less electricity consumption.

Energy efficiency COP (heating)

The general energy efficiency class that the air conditioner corresponds to when operating in heating.

This parameter is indicated by letters from A (highest efficiency) and beyond. It is directly related to the value of the COP coefficient (see "Heating COP"): each energy efficiency class corresponds to a certain range of coefficients (for example, C — from 3.2 to 3.4). Specific coefficient values for each class can be found in special tables; here we note that more efficient air conditioners are more expensive, but this difference can pay off due to less electricity consumption.
Cooper&Hunter Majesty CH-S12FTXAM often compared
Cooper&Hunter Supreme Continental CH-S12FTXAL2 often compared