USA
Catalog   /   Climate, Heating, Water Heating   /   Water Supply & Pumps   /   Water Leak Detectors

Comparison Akvastorozh Expert 1x25 Pro vs Akvastorozh Klassika 1x15

Add to comparison
Akvastorozh Expert 1x25 Pro
Akvastorozh Klassika 1x15
Akvastorozh Expert 1x25 ProAkvastorozh Klassika 1x15
Outdated ProductOutdated Product
TOP sellers
Main
Power supply from batteries and mains 230 V. Response time 2.5 sec. Crane performance monitoring. Prevention of cranes once every two weeks. Sound and LED indication. Backup power.
Sensor response time 2 – 3 sec. Battery backup. Sound and light indication. Crane failure alert.
In box
control unit
ball valve 1 pc
wired sensors 4 pcs
control unit
ball valve 1 pc
wired sensors 2 pcs
Sensor connectionwiredwired
Max. number of valves56
Fitting size1 "1/2 "
Closing time2.5 s3 s
Max. pressure16 bar16 bar
Max. liquid temp90 °С90 °С
Sensors shutdown
Valve exercise functiononce a weekonce a week
Power supply4.5 V4.5 V
Backup battery
Alarm
sound
wire break
valve failure
sound
 
valve failure
Valve materialbrassbrass
Added to E-Catalogoctober 2017september 2017

In box

Main system components supplied in the kit.

The finished delivery kit includes three components: a control unit (CU), a leakage sensor(s) and a special ball valve(s). At the same time, both control units(including those built into the valve) and valves can be sold completely separately. Let's take a closer look at each component:

- Control unit. The “brain” of the system, is directly responsible for its functioning: it receives signals from sensors and controls the valves. In this case, we mean a control unit made in the form of a separate device. Installing such a system is somewhat more complicated than in the case of a valve with a built-in control unit — it is necessary to ensure that the control unit is connected not only to the sensors but also to the valve(s). On the other hand, the control module can be placed in a convenient place. In addition, this kind of arrangement is optimal if you need to shut off several points in the water supply system at once: one common external unit for several valves, as a rule, is cheaper than several valves with built-in control units.

Cvalves with control unit. A control unit built directly into the ball valve is responsible for shutting off the water. This design makes it possible to reduce the dimensions of the system and...the total number of components in it, and, as a result, significantly simplifies installation. On the other hand, a built-in control unit is usually responsible only for its own valve and does not allow the connection of additional ones. So it makes sense to pay attention to this option mainly in three cases: either if you need to cover only one point, if compactness and a minimum number of components are crucial, or if there are difficulties with installing a remote control unit.

— Ball valve. A special valve driven by an electric motor shuts off the water supply based on a signal from the control unit. Note that the kit usually includes a small number of valves — no more than 3, while control units can support a larger number. This is done so that the customer does not overpay for extra valves when purchasing a set. If the standard equipment is not enough, additional valves can be purchased separately.

— Leakage sensor. A sensor that reacts to contact with water. When water gets on the touch surface, such a sensor sends a signal to the central unit, reporting a leak. Note that many systems allow the connection of more sensors than are supplied in the kit. The sensors themselves can use both wired and wireless connections to the control unit; some kits support both options at once. See “Sensor connection” for details.

Max. number of valves

The maximum number of electric valves that can be simultaneously connected to the control unit; in other words, the largest number of points at which the water supply can be shut off using this system. For home use, most often 2–3 taps are sufficient (hot water, cold water, washing machine/dishwasher); for larger buildings, a larger number may be required.

Fitting size

The size of the threaded connection used in motorized safety system valves. Traditionally plumbing equipment is indicated in inches. The most popular options are 1/2", 3/4" and 1"; moreover, the larger the size, the higher the maximum pressure that the valve is designed for, usually.

Closing time

The speed of the valve responds to an alarm signal. The faster the valve closes, the less water will spill from the depressurized circuit. A good response time is 2.5 s. For entry-level and mid-level leak protection systems, the normal response time is 5 to 7 seconds.

Sensors shutdown

Ability to temporarily disable individual sensors of the leak detection system.

In some cases, getting water on the sensor is not an emergency and does not indicate a leak — for example, if you decide to wash the walls in the bathroom where the sensor is installed. For such cases, it is possible to disable some sensors.

Alarm

Types of alerts provided in the protective system.

— Sound. Notification of various events with a sound signal. The most common use is to sound an alarm when a leak is detected to draw attention to the problem and possibly contain the water that has already spilt and prevent damage. In addition, there may be other reasons for sound notification — for example, a critically low battery.

Wire break alarm. Notification of a broken wire going to the wired sensor. Protective systems with this function during operation constantly monitor the connection with the sensors and give a signal when a break is detected. This avoids situations where the sensor does not work due to damage to the connecting wire.

Valve failure alarm. Leak detection systems with this function periodically check the operability of the valves and if problems are detected, they issue a warning. This reduces the likelihood that the valve will be broken and will not be able to perform its function.
Akvastorozh Klassika 1x15 often compared