Comparison TermoBar KS-GVS-12.5DS 12.5 kW vs TermoBar KS-GS-12.5DS 12.5 kW

Add to comparison
TermoBar KS-GVS-12.5DS 12.5 kW
TermoBar KS-GS-12.5DS 12.5 kW
TermoBar KS-GVS-12.5DS 12.5 kWTermoBar KS-GS-12.5DS 12.5 kW
from $203.70 up to $239.00
Outdated Product
from $189.26 up to $223.00
Outdated Product
TOP sellers
Energy sourcegasgas
Installationparapetparapet
Typedual-circuit (heating and DHW)dual-circuit (heating and DHW)
Heating area100 m²100 m²
Technical specs
Heat output12.5 kW12.5 kW
Power supply230 V230 V
Coolant min. T40 °С40 °С
Coolant max. T80 °С80 °С
Heating circuit max. pressure2 bar2 bar
Consumer specs
Performance (ΔT ~30 °C)5.2 L/min
Circulation pump
Boiler specs
Efficiency90 %90 %
Combustion chamberclosed (turbocharged)closed (turbocharged)
Inlet gas pressure13 mbar13 mbar
Max. gas consumption1.4 m³/h1.4 m³/h
Connections
Mains water intake1/2"
DHW flow1/2"
Gas supply1/2"1/2"
Safety
Safety systems
gas pressure drop
water overheating
flame loss
draft control
gas pressure drop
water overheating
flame loss
draft control
More specs
Dimensions (HxWxD)680x575x295 mm680x575x295 mm
Weight58 kg56 kg
Added to E-Catalogaugust 2014august 2014

Performance (ΔT ~30 °C)

The performance of a dual-circuit boiler in hot water mode when water is heated by approximately 30 °C above the initial temperature.

Performance is the maximum amount of hot water the unit can produce in a minute. It depends not only on the power of the heater as such, but also on how much water needs to be heated: the higher the temperature difference ΔT between cold and heated water, the more energy is required for heating and the smaller the volume of water with which the boiler can handle in this mode. Therefore, the performance of dual-circuit boilers is indicated for certain ΔT — namely 25 °C, 30 °C and/or 50 °C. And it is worth choosing according to this indicator, taking into account the initial water temperature and taking into account what kind of hot water demand there is at the installation site of the boiler (how many points of water intake, what are the temperature requirements, etc.). Recommendations on this subject can be found in special sources.

We also recall that water begins to be felt by a person as warm somewhere from 40 °C, as hot — somewhere from 50 °C and the temperature of hot water in central water supply systems (according to official standards) is at least 60 °C. Thus, for the boiler to operate in the mode ΔT ~ 30 °C and give out at least warm water at 40 °C, the initial temperature of cold water should be about 10 °C (10 + 30=40 °C). A similar temperature can be found in wells in the warm season, and cold water in the ce...ntralized water supply system often warms up to 10 °C in the warm season. However, boilers, including dual-circuit boilers, are switched on mainly in cold weather, when the initial water temperature is noticeably lower. Accordingly, if the boiler is used as the main water heater, heating to the claimed temperatures (see "DHW min. T", "DHW max. T") often requires a greater ΔT than 30 °C, and the performance is less than indicated in this paragraph. But when operating in the preheating mode (when the water is heated to the desired temperature by an additional device like a boiler), this parameter describes the capabilities of the unit very reliably.

Mains water intake

The diameter of the pipe for connecting the pipe through which cold water is supplied to the boiler for heating and use in the hot water supply system.

Diameters are indicated in inches. It is allowed to connect a pipe of a different diameter through an adapter, but the best option is still a match in size. There are connection options 1/2", 3/4", 1" and 1 1/2".

DHW flow

The diameter of the pipe for connecting the pipe through which hot water leaves the boiler for the DHW system.

Diameters are indicated in inches. It is allowed to connect a pipe of a different diameter through an adapter, but the best option is still a match in size.