USA
Catalog   /   Climate, Heating, Water Heating   /   Water Supply & Pumps   /   Water Heaters

Comparison Gorenje FTG 100 SMV9 vs Gorenje OGBS 100 ORV9

Add to comparison
Gorenje FTG 100 SMV9
Gorenje OGBS 100 ORV9
Gorenje FTG 100 SMV9Gorenje OGBS 100 ORV9
from $199.76 up to $273.52
Outdated Product
from $188.37 up to $249.60
Outdated Product
TOP sellers
Typestoragestorage
Energy sourcemainsmains
Installationuniversal (wall)vertical
Tank volume100 L100 L
2 tanks
Tank shapeflatrectangular
Technical specs
Power source230 V230 V
Power consumption
2600 W /1600+1000 W/
2000 W
Max. water temperature75 °C75 °C
Tank liningenamelenamel
Water supplywith pressurewith pressure
Heating time
192 min /at ∆t=55°С/
235 min
Magnesium anode
Heating elements22
Heating element type
wet heater
 
 
dry heater
Features
Functions
thermostat
Smart (auto mode)
thermostat
 
Safety systems
overheat protection
frost protection
dry heating protection
safety valve
anti-legionella
overheat protection
frost protection
 
safety valve
anti-legionella
General specs
Controlselectronicelectronic
Controls layoutfrontfront
Pipe connectioninstallation dependentbottom
Tank manufacturer's warranty5 years10 years
Dimensions (HxWxD)163.5x49x29.7 cm112.5x42x44.5 cm
Weight58 kg
Added to E-Catalognovember 2015august 2015

Installation

The regular way to install a water heater.

The choice for this parameter depends primarily on how much free space is available for installing the device and what shape this space has. Therefore, when there is a lot of space (for example, the user has an entire wall in the boiler room of a private house at his disposal), this parameter can be ignored. But in cramped conditions, each installation method will have its nuances.

Vertical. Vertical arrangement devices, elongated in height. This option is well suited for narrow cramped spaces — for example, a bathroom in a small city apartment.

Horizontal. The horizontal layout is less suitable for tight spaces than the vertical one but in some conditions, it may be optimal — for example, if the place under the device looks like a low horizontal niche. Also, note that many instant water heaters are produced in this design (see "Type") — they do not take up much space, and horizontal orientation is considered optimal for such devices for several reasons.

Floor. Floorstanding models (as opposed to all of the wall mount options described above). The main advantage of such an installation is simplicity: there is no need to drill walls and prepare other special fasteners; it is enough to have free space on the floor. In addition, weight restrictions are not so critical for floor water h...eaters, and this method can be used even for the most powerful, capacious and, accordingly, large models. On the other hand, free space on the floor is not always available, and this installation method is not suitable for cramped conditions.

— Universal (wall mounted). Devices that can be placed in any position — both horizontal and vertical (see above for details). The advantage of this option is obvious: the user can choose the installation method of his choice, depending on the situation.

2 tanks

The presence of 2 water tanks in the storage water heater; usually, the total volume is divided equally between these tanks.

This design is noticeably more complex and expensive than the traditional 1-tank arrangement but offers several advantages. Firstly, the tanks can be heated in turn, which significantly speeds up the process. After all, for hot water to be used, it is enough to warm up only half of the total volume to the operating temperature. Secondly, with this format of work, power consumption and the load on the power grid are reduced. And if at a certain moment, the user does not need a lot of water, then the energy consumption turns out to be small (again, because the entire volume does not need to be heated). Thirdly, compared to traditional models of the same volume, such boilers are thinner, which can simplify installation (the price for this advantage is an increase in width, but this moment is not so often critical). Fourth, this arrangement improves thermal insulation and reduces heat loss.

Tank shape

The shape of the water heater.

The traditional options are cylindrical and rectangular, but nowadays there are more specific options — flat cases, slim cylindrical devices. Here are the features of each of these options:

— Cylindrical. This form is traditional for storage water heaters. It is because with the same total volume, less material is needed for a cylindrical tank than for a rectangular one; and in production, such tanks are simple and cheap, which allows them to be used in water heaters of any price category. The disadvantages of this form include, first of all, some bulkiness in comparison with other options.

— Rectangular. The case is rectangular in shape, with pronounced front and side faces; the corners can be both sharply defined and rounded. It is the traditional form for instant water heaters, primarily gas, but it can be found in a fairly large number of storage models. Accordingly, the features of a rectangular case will be different — depending on the type of heater. So, in instant water heaters, the “rectangle” is simply one of the most convenient options in terms of the overall layout. But in storage water heaters, this shape differs from the flat one (see below) only with a slightly greater thickness and, in some cases, pronounced angles.

— Flat. A variant found mainly in s...torage electric heaters. Such devices look as if the classic cylindrical body was flattened at the back and front, reducing its thickness by increasing the width (and sometimes height). Thus, such a boiler does not protrude as much in front of the wall as a cylindrical one; in some cases, this point may be fundamental — for example, when installed in a bathroom, where a cylindrical device would hang over the toilet bowl, creating discomfort.

— Slim. A variety of cylindrical cases are characterized by a reduced diameter. In other words, boilers from this category are also round, but with the same volume, they have a noticeably smaller width and thickness than traditional cylindrical ones. In cramped conditions, this can be very useful. However, it must be borne in mind that the price for reducing the diameter is an increase in height.

Power consumption

Electrical power consumed by the heater during operation.

This parameter is of key importance for electric models (see "Energy source"). In them, the power consumption corresponds to the power of the heating element and, accordingly, the heat output of the entire device. The overall efficiency and flow rate of the water heater directly depend on the useful power. Accordingly, high-flow rate models inevitably have high consumption. At the same time, we note that the heating power is selected by the designers in such a way as to guarantee the necessary flow rate and water temperature. So when choosing a device according to flow rate, you need to look primarily at flow rate and temperature. Power must be taken into account when connecting: for example, if a 220 V model (see "Power source") consumes more than 3.5 kW, it, as a rule, cannot be plugged into a regular outlet — connection is required according to special rules. And the most productive and high-powered models — 10 kW or more — are connected only to three-phase mains.

The power consumption has a similar value for combined boilers — adjusted for the fact that in them the electric heater is an additional source of heat. For gas and indirect models, this parameter describes the power consumption of control circuits and other auxiliary structural elements; this power consumption is usually very small — on the order of several tens of watts, less often up to 1.5 kW.

Heating time

Time to heat the storage tank (see "Type"), filled with cold water, to operating temperature.

It is worth remembering that this characteristic is not 100% accurate. Manufacturers usually indicate the heating time for certain conditions: a filled tank, maximum heating intensity, and temperature rise (∆T) by a certain number of degrees. In practice, the heating time may differ, both one way and the other. For example, if the heating time for the device is 20 minutes at ∆T = 50 °C, then when the water is heated from 15 °C to 60 °C, the time will be shorter (∆T = 45 °C). Nevertheless, this indicator allows us to evaluate the overall flow rate of the boiler, and with equal ∆T and volumes, different models can be compared in terms of heating time.

Heating element type

Open coil. The open coil is made from a high-resistance electrical wire enclosed in a thin insulating sheath. The main advantages of such an element are the heating rate, high efficiency and precise temperature control; in addition, scale is almost not formed on the spiral. And of the shortcomings — a low service life.

Wet heating element. Wet heater is a metal tube with a heating thread laid in the centre; the space between the tube and the thread is filled with an insulating material with good thermal conductivity. Heating elements heat up more slowly than open coils, have lower efficiency and are prone to the formation of scale on them; on the other hand, their service life is much longer, and in instant heaters, heating elements are not so sensitive to air pockets.

Dry heating element. A kind of heating element with an improved design: the heater tube is enclosed in an additional shell (most often made of metal with an enamel coating on the outside) and does not come into contact with water, hence the name. Thanks to this, the likelihood of scale formation is reduced, which is especially important when working with hard water. Also, the replacement of such elements is significantly easier than conventional ones. Among their shortcomings can be called a rather high cost.

Infrared heating element. Tu...bular electric heater of a special design: in the form of a transparent glass tube, in which the incandescent spiral is enclosed. The principle of operation of such an element is somewhat different from a conventional heating element: a significant part of the heating is provided by infrared radiation, which heats not so much the water as the walls of the tank — and heat is already transferred from them to the water. Thus, the water is heated not only at the point of contact with the heating element but also at the point of contact with the walls — which means that the heating is faster and more uniform. Also, note that the IR heater itself is usually "dry"; see above for the advantages of this design. The main disadvantages of such heaters are high cost and relatively short service life.

— Heat exchanger. It is used in gas and indirect heaters (see Water heater type). It is a metal structure heated by burning gas (in gas heaters) or passing inside a heated coolant (in indirect heaters). Usually has a ribbed shape. It is done to ensure the maximum area of contact with the heated water with relatively small dimensions — the larger this area, the more heat is transferred to the water per unit of time and the more efficient the heater is.

Functions

Among the functions of the water heater there are thermostat, water flow regulator, Smart (auto mode), programmer, display and control via the Internet. More about each of them

— Thermostat. A device that allows you to control the temperature of the water at the outlet of the heater. In storage models (see "Type"), the thermostat sets the maximum temperature for heating water in the tank; in instant devices, this function is carried out by changing the intensity of heating.

— Automatic water flow regulator. It is used in instant water heaters. Since the water in such devices heats up in the process of its movement through the heater, the higher the speed of water movement (the greater the pressure), the lower the heating temperature, and if the pressure is too high, the power of the device may simply not be enough for effective heating. The use of an automatic water flow regulator avoids this — this system regulates the speed of water movement through the heater, limiting it if necessary.

— Smart (auto mode). A special “smart” mode in which the boiler is controlled (primarily the intensity of heating) automatically. Specific features of this mode may vary depending on the model. However, the following format of operation is most common: during...the first week of use, the device remembers at what time of the day the hot water was used, and then the heater’s operating mode adjusts to this data. Thus, the water heater provides the user with hot water at the right time and, at the same time, does not waste energy on heating during hours when heating is not needed.

— Programmer. The presence of a programmable thermostat — a device that allows not only to maintain the temperature but also to programme the operation of the device for a certain period. The simplest programmers work like a timer, turning on at the right time (vacation or holiday mode, when the device is not active for several days, and when the family returns to the house, it will turn on and heat the water). More advanced ones allow you to set the mode of operation for individual days. Either way, this feature provides added convenience and eliminates the need to constantly adjust the operation of the device manually. On the other hand, the presence of a programmer affects the cost.

— Display. Usually, a simple LCD screen with a few characters is used as a display. However, even such equipment significantly increases the convenience and information content of management. Various service data can be shown on the display — from the temperature of the water in the tank to messages about malfunctions and failures. This feature slightly increases the cost of the device, but compared to the total cost of the heater, this moment is usually insignificant.

— Control via the Internet. The specific nuances of such control may vary: for example, some models use a special application installed on a smartphone or tablet, while others can work through a regular browser from any computer. However, this function allows you to control the heater from almost anywhere in the world — provided that there is access to the Internet. In addition, with this control, the user can also monitor the status of the device and receive various notifications (on and off, about the temperature of the water in the tank, about various problems, etc.).

Safety systems

The safety of water heaters can be carried out by such functions as overheat protection frost protection, dry heating protection, surge protection, electrical protection (RCD), anti-legionella, gas control and draft sensor. More about them:

— Overheat protection. Water heater safety system that automatically turns off the power supply or gas supply (depending on the type) when the heating element reaches a critical temperature. It avoids overheating and the troubles associated with it, ranging from heater failure to fire.

— Frost protection. Function to prevent freezing of water in the circuits, tank and/or heat exchanger of the water heater. It will be useful when the device is installed in a room with a low temperature and works with long breaks. Frozen water expands, which can damage the device; to avoid this, the frost protection monitors the temperature of the water in the device and turns on the heating when this temperature drops to a critical level.

— Dry heating protection. A safety system that prevents the heater from being switched on without the presence of water in it. Since the heating element does not transfer heat to the water when turned on, it heats up very q...uickly and, in a short time, reaches a high temperature that can lead to damage to the heater and even to a fire. The presence of protection against switching on without water allows you to avoid such unpleasant consequences.

— Voltage surge protection. System for protecting the heater from power surges. Electronically controlled models are usually equipped with such protection (see Control) since it is the control electronics that are most sensitive to problems with the power supply. Note that the capabilities of such systems are noticeably more modest than those of specialized stabilizers or protective systems: the “hardware” of a water heater can smooth out relatively weak power surges, but in case of serious failures, it will most likely simply turn off the device to avoid damage. However, this feature will be useful; except that in very unstable electrical grids, prone to frequent fluctuations, such a heater may require an external stabilizer.

— Electrical protection (RCD). Built directly into the heater, the RCD is a residual current device. Such a device is primarily intended to protect people from electric shock — for example, if the insulation is damaged and electricity leaks into the case or water. When a person comes into contact with this electricity, a so-called leakage current occurs. The RCD reacts to it and almost instantly turns off the power to the boiler, preventing electric shock.
Note that such safety devices are standardly installed directly in switchboards. However, the presence of an RCD in the water heater provides additional security. Naturally, such equipment is found mainly in electric models.

— Safety valve. A safety system that prevents a critical increase in water pressure in the heater. Usually, this protection is based on a safety valve that opens when a certain pressure level is reached and drains excess water, avoiding damage to the heater.

— Gas control. Gas heater safety system that automatically shuts off the gas supply in the event of a burner flame failure. It avoids filling the room with gas and possible unpleasant, and even tragic consequences. Resuming the gas supply after the protection is triggered must be done manually.

— Draft sensor. A sensor that monitors the presence of draft in the flue of a gas water heater. This function is especially important for models with open combustion chambers: in the absence of a draft, combustion products will fill the room where the heater is located. And this, in turn, can lead to a deterioration in people's well-being, health problems and even deaths. To avoid such consequences, this sensor, when detecting problems with the draft, turns off the gas supply and issues a warning about the problem. However, such equipment can also be found in models with closed combustion chambers. In them, the draft sensor performs mainly a diagnostic function, allowing you to determine what interferes with the normal operation of the burner.

— Anti-legionella. A function that prevents the growth of pathogenic bacteria in the tank and water heater circuits. Some types of such bacteria can live and multiply in fairly hot water — up to 60 °C. To avoid this, the anti-legionella system monitors the temperature of the water in the tank and periodically raises it to a level of about 65 °C. The specific methods of operation of such systems can be different: for example, some work strictly according to a set schedule (for example, once every two weeks), others turn on additional heating only if for some period (for example, a month) the water has not been heated to sufficiently high temperatures.

Pipe connection

The direction from which pipes are connected to the heater. The choice for this parameter depends primarily on the characteristics of the place where the device is planned to be placed. Note that in universal models (see "Installation"), the place of connection of pipes depends on the method of installation, while specific options in different models may be different, this should be specified separately.
Gorenje FTG SMV9 often compared
Gorenje OGBS ORV9 often compared