USA
Catalog   /   Tools & Gardening   /   Machines & Equipment   /   Air Compressors

Comparison Forte COF-6 6 L
230 V
vs Stal KST-24 24 L

Add to comparison
Forte COF-6 6 L 230 V
Stal KST-24 24 L
Forte COF-6 6 L
230 V
Stal KST-24 24 L
Outdated ProductOutdated Product
TOP sellers
Main
Oil free. Compact dimensions and light weight.
Compressor typepistonpiston
Designoil-freeoil-lubricated
Drivedirectdirect
Specs
Input performance80 L/min190 L/min
Rated pressure7 bar8 bar
Power0.75 kW1.5 kW
Rotation speed2850 rpm2850 rpm
Number of cylinders11
Number of steps11
Receiverhorizontalhorizontal
Receiver volume6 L24 L
Power sourcemains (230 V)mains (230 V)
General
Design features
 
transportation wheels
Dimensions36x31x35 cm56x27x58 cm
Weight9.5 kg15.2 kg
Added to E-Catalogseptember 2018december 2017

Design

The criterion for separating compressors according to this parameter is whether oil is necessary for the normal operation of the device.

Oily. Compressors that use oil during operation have a high motor resource (due to the fact that friction in their mechanism is reduced due to the presence of lubrication) and a lower noise level than oil-free ones. On the other hand, they are much more difficult to maintain and more expensive to operate. the oil supply has to be replenished periodically; and during operation, such a unit should be located on a flat horizontal surface. In addition, the outgoing air contains tiny drops of oil. Therefore, oil-based devices are poorly suited for certain types of work — for example, in the food industry, where such impurities are unacceptable, the use of special fine filters will be required.

Oil free. The main advantage of oil-free models can be called the purity of the exhaust air — it does not contain oil droplets and in most cases does not require additional purification. This makes these compressors perfect for medical, food and paint applications. In addition, they are simpler in design (respectively, in repair), do not require the hassle of providing lubrication, and can work in almost any position. On the other hand, high friction of parts significantly increases wear, which accordingly affects the resource.

Input performance

The amount of air that the compressor is able to process per unit of time; usually stated in liters per minute. Performance, along with pressure (see below), is one of the most important parameters: it is it that primarily determines how compatible the compressor will be with one or another pneumatic tool.

It is worth choosing a model according to this indicator in such a way that it can be guaranteed to “pull out” all the tools that can be connected at the same time. Air consumption is usually directly indicated in the characteristics of each tool, and it is quite simple to calculate the total requirement. However, due to the design features, the compressor must have a certain performance margin; the specific value of this stock depends on a number of nuances.

The main point is that some companies indicate for their units the performance at the outlet (how much air is supplied to the tool), while others indicate at the inlet (how much air the compressor sucks in). Since no compressor is perfect, part of the air is inevitably lost during the compression process, so the amount of air at the outlet will always be less than at the inlet. Accordingly, if the output performance is indicated in the characteristics, a margin of 10-20% is recommended, and if the input is 35-40%.

There are also more complex techniques that allow you to more accurately derive the required performance depending on the characteristics of specific tools; they can be found in...special sources.

Rated pressure

The maximum pressure created by the compressor during operation. This parameter, as well as the performance described above, is very important for selecting a compressor for a specific pneumatic tool: it is necessary that the nominal pressure be not lower than the working pressure of the tool. At the same time, high pressure is not a problem — it can be reduced by the appropriate regulator on the gearbox.

Most modern compressors have a pressure rating of 8 bar, which is sufficient for most air tools. Units for 6 bar belong to the entry level, their main purpose is painting work, where high pressure is not required. There are also options for 10 bar and even more — they, usually, belong to specialized models and cost accordingly. Therefore, it is worth looking specifically for a high-pressure unit only if this parameter is critical for the planned work (for example, if you need a compressor for tyre fitting).

When selecting according to the nominal pressure, it must be taken into account that the maximum allowable pressure in the receiver is usually indicated as the nominal pressure. The pressure actually given out by the compressor to the outlet is often somewhat less, this is due to some design features. For the most popular nominal pressure options — 8 and 10 bar — the real figures are usually 2 bar less, i.e. 6 and 8 bar respectively.

Power

The power of the engine installed in the compressor. It is not the main parameter in evaluating the efficiency of the device — here the performance and nominal pressure play a decisive role (see above), and the engine is selected in such a way that its power is sufficient to ensure the claimed characteristics. However, this indicator still has practical significance: in compressors with an electric motor (and there are now most of them; see “Engine type”), the engine power determines the total energy consumption of the device, as well as the requirements for the network where it is planned to connect it (for more details, see “Voltage networks"). In addition, the power of the engine (regardless of its type) must be known in order to calculate the optimal performance value using some special formulas.

For internal combustion engines, power is traditionally expressed in horsepower (hp); you can convert it to watts in this way: 1 hp. = 735 W.

Receiver volume

The receiver is a tank (cylinder) into which compressed air is pumped during operation of the compressor; it is from this cylinder (and not directly from the working mechanism) that it is fed to the connected instrument. The main meaning of such a scheme is that the receiver compensates for pressure unevenness that occurs during the operation of the main mechanism; it does not guarantee absolute constancy, however, all changes occur very smoothly. In addition, energy savings are ensured in this way: part of the time the compressor runs on the stored air from the receiver, and the engine turns on only when the pressure in the tank is significantly reduced to replenish supplies. Therefore, this piece of equipment is practically mandatory, models without a receiver are extremely rare today.

In general, the larger the volume of the receiver, the less often it will have to be pumped up after the initial filling with compressed air. It is also believed that a volumetric receiver can partly compensate for the lack of compressor performance; however, this moment does not ensure the constant stable operation of the “gluttonous” tool and serves only as a fallback in case of a short-term increase in air consumption. On the other hand, large volumes mean the corresponding dimensions of the tank (and it is already the largest part in most compressors), and the cost of the device increases accordingly. Therefore, when choosing, it is worth observi...ng a certain balance and choosing a receiver depending on the specifics of the work. For various types of activities there are recommendations, they can be found in special sources. Here we note that for relatively uniform work in time with a small air flow, a small receiver is usually enough, and if peak loads can occur frequently, it is better to choose a larger cylinder.

Some compressors may provide the expansion of the receiver with additional tanks.

Design features

Frequency converter. This function is used to automatically control the power of the motor in the compressor (see "Motor type"), more precisely, to adjust the speed to the current air consumption and maintain a constant pressure.

In electrical units, in addition to reducing wear and tear and eliminating current surges in the network, such systems provide the most stable air pressure at the outlet, and energy is spent more rationally. At the same time, frequency converters are expensive and take up quite a lot of space; and the advantages mentioned are relevant for heavy professional-grade equipment. Therefore, this function is found mainly among industrial compressors with an operating voltage of 400 V and based on internal combustion engines.

Dehumidifier. The purpose of such devices is already clear from the name: they are designed to dry the air at the compressor inlet, that is, to remove excess moisture from it. The need for such a procedure is primarily due to the fact that high humidity adversely affects the state of the compressor: it leads to condensate settling, and it, in turn, contributes to corrosion and the formation of various emulsions, due to which the channels become dirty and the wear of the entire unit increases .

Tandem. Devices created according to the "tandem" scheme are actually two compressors on one receiver, connected...in parallel. This allows you to turn on both compressors at once, or only one of them — in this way you can adjust the power and performance even in those models where special regulators such as a frequency converter (see the relevant paragraph) are not provided at all.

Among the disadvantages are heavy weight, bulkiness and high cost. In addition, the tandem operation scheme is mainly suitable for powerful performant units — otherwise the individual compressors would have to be made too small, and this does not make sense.

Wheels for transportation. The presence of special transport wheels in the design of the compressor. Modern compressors can be of considerable weight, which would require the participation of several people when carried; wheels, on the other hand, allow you to move even rather weighty devices without problems by the forces of one, in extreme cases — two people.
Forte COF-6 often compared
Stal KST-24 often compared