Comparison Kermi Therm-X2 Profil-V 33 300x1200 vs Korado Radik VK33 300x1200

Add to comparison
Kermi Therm-X2 Profil-V 33 (300x1200)
Korado Radik VK33 (300x1200)
Kermi Therm-X2 Profil-V 33 300x1200Korado Radik VK33 300x1200
from $119.96 up to $226.83
Outdated Product
from $130.56 up to $144.72
Outdated Product
TOP sellers
Radiator typepanelpanel
Country of originGermanyCzech Republic
Manufacturer's warranty10 years10 years
Technical specs
Materialsteelsteel
Panel type3333
Operating pressure10 bar10 bar
Max. pressure13 bar13 bar
Heat transfer medium volume4.15 L6.36 L
Heat tranfer medium max. temperature110 °C110 °C
Mountingwallwall
Connectionbottom sidebottom side
Pipe centre distance50 mm50 mm
Connection size3/4"1/2"
Heat output2204 W2015 W
Radiator height300 mm300 mm
Radiator width1200 mm1200 mm
Radiator depth155 mm155 mm
Weight30.17 kg
Added to E-Catalogapril 2015march 2015

Country of origin

The country of origin of the brand.

In most cases, either the homeland of the brand or the location of the manufacturer's headquarters is indicated as the country of origin. Production facilities may well be located in another country. However, it is worth noting here that most of the national stereotypes nowadays are unfounded — the quality of products depends not so much on geography but on the characteristics of the organization of the production process in a particular company. So from this point of view, when choosing, you should focus primarily on the reputation of a particular manufacturer. It makes sense to pay attention to the country of origin of the brand if you fundamentally want (or do not want) to support a company from a certain state.

Nowadays, the production of radiators is mainly carried out by companies from such countries: England, Belarus, Belgium, Germany, Holland, Spain, Italy, China, Norway, Poland, Russia, Turkey, Ukraine, Finland, ...>Czech Republic.

Heat transfer medium volume

The volume of water or other heating medium required to fill the radiator.

This information is relevant mainly when building an autonomous heating system: it is useful when calculating the total volume of heating medium in the system and related parameters. If the radiator is purchased for use in centralized heating, you can not pay much attention to its internal volume.

Connection size

The diameter of the thread used to connect the radiator to the heating system. Modern radiators use standard sizes — for example, 3/4" or 1/2", less often 1" and 1 1/4". This indicator must match the dimensions of the pipes, couplings and other elements directly used for connection — otherwise, at best, you will need to install adapters, and at worst, the radiator will turn out to be unusable at all.

Usually, the larger the thread diameter, the more powerful the radiator (high power requires intensive circulation of the heating medium and an appropriate throughput at the inlet and outlet).

Heat output

The rated thermal output of the radiator is the amount of heat given off to the air in normal operation.

When choosing this parameter note that the heat output will depend on the temperature difference at the inlet and outlet to the radiator, as well as on the ambient temperature. The greater the temperature difference and the colder it is around, the more intense the heating will be. Therefore, in the specs, it is customary to indicate heat transfer for certain standard conditions. In particular, the designation according to the European standard EN-442 is very popular, which assumes heating medium temperatures of +75 °С and +65 °С at the inlet and outlet, respectively, as well as an air temperature of +20 °С. Real conditions and the actual heat output of the radiator may differ; therefore, when choosing, it is best to choose a model with a certain margin and compensate for excess power with one or another regulator. As for the actual values, in the most modest models, the heat outputdoes not exceed 750 W, or even 500 W, and in the largest, this figure can reach 3.5 – 4 kW or more.

The choice for this parameter depends primarily on the size and specs of the heated space. The simplest calculation formula is as follows: at least 100 W of thermal power is required per 1 m2 of area. This formula is relevant for standard r...esidential/office premises with ceilings of 2.5 – 3 m, without problems with thermal insulation; for more specific conditions, there are more detailed calculation methods, that can be found in special sources.