USA
Catalog   /   Large Appliances   /   Water Coolers

Comparison Ecotronic H1-LCE vs Ecotronic H1-L

Add to comparison
Ecotronic H1-LCE
Ecotronic H1-L
Ecotronic H1-LCEEcotronic H1-L
Outdated Product
from $82.68 up to $176.68
Outdated Product
TOP sellers
Main
Stainless steel cold water tank. High cooling performance.
Installationfloorfloor
Water loadingtoptop
Features
Water temperature
hot
cold
hot
cold
Cooling typethermoelectric (Peltier)compressor
Cold water tank volume0.8 L4 L
Hot water tank volume1.1 L1.2 L
Cooling performance
0.7 L/h /10°C/
3 L/h /10°C/
Heating performance
5 L/h /90°C/
5 L/h /90°C/
Heating power500 W500 W
Cooling power68 W90 W
More specs
Water supply controlcup pressurecup pressure
Lighting
 /volume: 16 L/
Dimensions (WxDxH)34x34x101 cm31x32x96 cm
Weight7.5 kg
Color
Added to E-Catalogmarch 2018november 2016

Cooling type

The type of cooling provided in the design of the device with the possibility of supplying cold water (see above).

— Compressor. Such cooling systems are similar in principle to refrigerators: they use a closed circuit with a refrigerant (usually freon) and a compressor to circulate the refrigerant. The circuit consists of an evaporator, a radiator and connecting pipes. This system works as follows: freon, evaporating, takes heat from the walls of the evaporator and the water in contact with them, cooling it; then it enters the radiator, condenses and gives off excess heat, which is quickly dissipated in the surrounding air due to the special design of the radiator. Compressor systems are somewhat more complex and expensive than electronic ( thermoelectric) systems. Intricate repairs with refrigerant replacement may be required if the circuit is damaged. On the other hand, such cooling has high efficiency and productivity; and it is practically independent of the ambient temperature: in hot weather, energy consumption may increase slightly, but the outlet water temperature will remain unchanged. Note that the compressor allows you to add a real refrigerator to the device (see "Locker").

— Thermoelectric (Peltier). In this case, electronic cooling systems are built on Peltier elements — a special kind of converters that look like plates. When current is passed through such a converter,...one side of the plate is cooled, and the other side is heated. Usually, water does not directly contact such a converter; cooling is carried out due to the flow of cold air created by a fan. Compared to compressor refrigerators, electronic systems are much simpler, more reliable, smaller and cheaper. On the other hand, with higher power consumption, they have lower performance. And the efficiency of Peltier elements is not very high — in particular, they cool water not to a certain temperature, but to a certain number of degrees relative to the ambient temperature (usually 10 – 15 °C). It makes it difficult to get cold water in hot weather.

Cold water tank volume

The volume of the cold water tank provided in the device.

In this case, it means a tank for water specially cooled by the device (see "Water supply"). The volume of the tank is the maximum amount of cold water that the cooler can dispense in one run, without interruption or with minimal interruptions. When this amount is exhausted, you will have to wait until the water in the tank cools down again to a sufficient degree; the waiting time depends on the cooling capacity (see below). At the same time, the volume of cold water tanks in modern devices is usually several litres, and it is extremely rare to drain this entire volume; usually, small portions of 200-300 mL are required. Therefore, this tank plays the role of a buffer — when the user drains the next portion of water, water from a bottle or a water mains is added to the tank; such an admixture does not particularly affect the temperature in the tank, however, for an additional guarantee, the cooling system immediately turns on. Thus, if consumption does not exceed productivity.

Hot water tank volume

The volume of the hot water tank provided in the device.

This parameter describes the maximum amount of hot water that the cooler can produce in one run, without interruption or with minimal interruptions. When this amount is exhausted, you will have to wait until the water in the tank heats up again to a sufficient degree; the waiting time depends on the heating capacity (see below). At the same time, the volume of hot water tanks in modern devices is usually several litres, and it is extremely rare to drain this volume entirely — usually, small portions of 200-300 mL are required. Therefore, this tank plays the role of a buffer — when the user drains the next portion of water, water from a bottle or a water mains is added to the tank; such an admixture does not particularly affect the temperature in the tank, however, for an additional guarantee, the heating system immediately turns on. Thus, if the consumption does not exceed the heating capacity, the temperature of the contents remains practically unchanged.

Cooling performance

The performance of the cooling system installed in the device, in other words, is the amount of water that can be cooled per hour. In coolers, it is usually indicated for water at room temperature — about 20 °C, in models with a connection to the water mains (see "Water loading") — for 15 °C (this is the average temperature of cold water). Accordingly, when deviating from these indicators, the actual performance may be slightly more or less (however, such deviations must be very significant for this to become noticeable).

This parameter determines two main points. First of all, it characterizes the maximum flow of cold water that the device can handle and the recommended breaks between use. For example, if a user needs to collect 2 standard 200-gram cups and the cooler specifications state a cooling capacity of 2 L/h, this means that the cooler will cool 400 g (0.4 L) of water that has entered the tank, for 0,4/2 = 0.2 h, that is about 12 minutes. However, the need for such calculations arises mainly with high water consumption, which is very close to the claimed performance.

Also, knowing the cooling rate and the volume of the cold water tank (see above), you can determine how long it will take to cool the tank filled with water at room temperature. Such situations arise during the first use of the device, as well as when draining the entire volume of the reservoir. So, if in the above example, the volume of the tank is 3 litres, then 3/2 = 1.5 hours...will be spent on cooling it. However, you can use water earlier, if a slightly elevated temperature is not critical.

Cooling power

It is the power consumed by the device in water cooling mode. In other words, this is the power required for the operation of all elements of the cooling system — a compressor or a converter with a fan (depending on the type of cooling, see above).

This parameter is directly related to the cooling performance (see above): a high cooling rate inevitably requires appropriate power. However, with the same power, compressor systems are more performant than electronic ones. Only models with coolers of the same type can be compared in terms of power.

Also note that the cooling system does not consume this power constantly, but only when necessary. So, at room temperature of the water in the "cold" tank, it turns on at full capacity, and when the desired temperature is reached, it switches to its maintenance mode, which requires much less energy.

In cooling-only models, this figure describes the maximum power consumption of the entire device. And, if there are two modes (heating and cooling), the total maximum power consumption corresponds to the sum of the powers of both modes.

Lighting

The presence of a lighting system in the design of the cooler.

It can perform both decorative and practical functions. So, in some models, the lighting plays the role of an indicator signalling the readiness of water and other parameters of the device. Also, this function can be useful in low light conditions, making both individual elements (taps, levers, etc.) and the entire device more visible, reducing the risk of bumping into it in the dark.
Ecotronic H1-L often compared