USA
Catalog   /   Computing   /   Components   /   Computer Cooling

Comparison Deepcool Maelstrom 120T vs Deepcool Maelstrom 240T

Add to comparison
Deepcool Maelstrom 120T
Deepcool Maelstrom 240T
Deepcool Maelstrom 120TDeepcool Maelstrom 240T
Outdated Product
from $85.96 
Outdated Product
TOP sellers
Main
Waterblock lighting.
Main specs
Featuresfor CPUfor CPU
Product typeliquid coolingliquid cooling
Max. TDP140 W150 W
Fan
Number of fans12
Fan size120 mm120 mm
Bearinghydrodynamichydrodynamic
Min. RPM600 rpm
Max. RPM1800 rpm1800 rpm
Speed controllerauto (PWM)auto (PWM)
Max. air flow83.64 CFM83.64 CFM
Static pressure3.08 mm H2O
MTBF50 K hours50 K hours
replaceable
Min noise level18 dB
Noise level34 dB34 dB
Power source4-pin4-pin
Radiator
Heatsink materialaluminium / copperaluminium
Socket
AMD AM2/AM3/FM1/FM2
AMD AM4
Intel 1150
Intel 1155/1156
Intel 1366
Intel 2011 / 2011 v3
Intel 2066
Intel 1151 / 1151 v2
Intel 1200
AMD AM2/AM3/FM1/FM2
AMD AM4
Intel 1150
Intel 1155/1156
Intel 1366
Intel 2011 / 2011 v3
Intel 2066
Intel 1151 / 1151 v2
Intel 1200
Liquid cooling system
Heatsink size120 mm240 mm
Pump size70x86x32 mm70x86x32 mm
Pump rotation speed2400 rpm2400 rpm
Pump MTBF120 K hours120 K hours
Pipe length300 mm
General
Lighting
Mount typebilateral (backplate)bilateral (backplate)
Dimensions
154x120x22 mm /radiator/
274x120x27 mm /radiator/
Weight757 g1100 g
Added to E-Catalognovember 2017november 2017

Max. TDP

The maximum TDP provided by the cooling system. Note that this parameter is indicated only for solutions equipped with heatsinks (see "Type"); for separately made fans, the efficiency is determined by other parameters, primarily by the air flow values (see above).

TDP can be described as the amount of heat that a cooling system is able to remove from a serviced component. Accordingly, for the normal operation of the entire system, it is necessary that the TDP of the cooling system is not lower than the heat dissipation of this component (heat dissipation data is usually indicated in the detailed characteristics of the components). And it is best to select coolers with a power margin of at least 20 – 25% — this will give an additional guarantee in case of forced operation modes and emergency situations (including clogging of the case and reduced air exchange efficiency).

As for specific numbers, the most modest modern cooling systems provide TDP up to 100 W, the most advanced — up to 250 W and even higher.

Number of fans

The number of fans in the design of the cooling system. More fans provide higher efficiency (all else being equal); on the other hand, the dimensions and the noise generated during operation also increase accordingly. Also, note that other things being equal, a smaller number of large fans is considered more advanced than numerous small ones; see "Fan diameter" for details.

Min. RPM

The lowest speed at which the cooling fan is capable of operating. Specified only for models with speed control (see below).

The lower the minimum speed (with the same maximum) — the wider the speed control range and the more you can slow down the fan when high performance is not needed (such a slowdown allows you to reduce energy consumption and noise level). On the other hand, an extensive range affects the cost accordingly.

Static pressure

The maximum static air pressure generated by the fan during operation.

This parameter is measured as follows: if the fan is installed on a blind pipe, from which there is no air outlet, and turned on for blowing, then the pressure reached in the pipe will correspond to the static one. In fact, this parameter determines the overall efficiency of the fan: the higher the static pressure (ceteris paribus), the easier it is for the fan to “push” the required amount of air through a space with high resistance, for example, through narrow slots of a radiator or through a case full of components.

Also, this parameter is used for some specific calculations, however, these calculations are quite complex and, usually, are not necessary for an ordinary user — they are associated with nuances that are relevant mainly for computer enthusiasts. You can read more about this in special sources.

Min noise level

The lowest noise level produced by the cooling system during operation.

This parameter is indicated only for those models that have capacity control and can operate at reduced power. Accordingly, the minimum noise level is the noise level in the most “quiet” mode, the volume of work, which this model cannot be less than.

These data will be useful, first of all, to those who are trying to reduce the noise level as much as possible and, as they say, “fight for every decibel”. However, it is worth noting here that in many models the minimum values are about 15 dB, and in the quietest — only 10 – 11 dB. This volume is comparable to the rustling of leaves and is practically lost against the background of ambient noise even in a residential area at night, not to mention louder conditions, and the difference between 11 and 18 dB in this case is not significant for human perception. A comparison table for sound starting from 20 dB is given in the "Noise level" section below.

Heatsink material

Copper. Copper has a high thermal conductivity and provides efficient heat dissipation, but such radiators are quite expensive.

Aluminium. Aluminium is cheaper than copper, but its thermal conductivity, and, accordingly, its efficiency is somewhat lower.

Aluminium/copper. Combined design — usually, a radiator is made of aluminium, and heat pipes are made of copper. This combination achieves good performance without a significant increase in cost. This type of heatsink applies only to active coolers.

Heatsink size

The nominal size of the radiator provided in the water cooling system.

The radiator provides cooling of the heated coolant coming from the cooled components of the system. It most often works on the principle of a cooler — that is, it consists of the actual radiator and one or more fans. The size of the radiator is indicated by one number — by the largest dimension, length. And the width (on which the working area and, accordingly, efficiency depends) can be determined based on the length. The fact is that radiators use fans of two diameters — 120 and 140 mm; if there are several such fans, they are installed in a row. This means that the length of the structure will necessarily be a multiple of the fan diameter — 120 or 140 mm, and the width will correspond to this diameter. For example, a 120mm or 140mm product would have the same width and one fan, while a 240mm product would have two 120mm fans.

The described features lead to the fact that a larger size does not necessarily mean a more advanced design. So, a 360mm or even 420 mm radiator with three small fans can have the same or even lower efficiency than a 280mm model. In addition, we recall that larger fans with the same performance are slower, and therefore quieter.

Also, the size o...f the radiator must be taken into account when looking for a seat in the case for it. Be aware of the width as well: 140mm fan heatsinks are usually not compatible with 120mm fan heatsink slots. So, a 140 mm model will not fit in a 240 mm (2x120 mm) socket, and 280 mm (2x140 mm) will not fit under 360 mm (3x120 mm), although formally the size seems to be enough in both cases.

Pipe length

The length of the tubes connecting the water block to the radiator in a water cooling system. By definition, there are at least two such tubes (supply and return), and sometimes more, but they all have the same length. This length corresponds to the largest distance from the water block to the radiator, possible for this system in the standard configuration; this nuance must be taken into account when choosing water cooling for a specific installation location. In general, most models are 38 or 40 cm long, which is enough for basic needs.

Dimensions

General dimensions of the cooling system. For water systems (see "Type"), this paragraph indicates the size of the external radiator (the dimensions of the water block in such devices are small, and there is no need to specify them in particular).

In general, this is a fairly obvious parameter. We only note that for case fans (see ibid.), the thickness is of particular importance — it directly depends on how much space the device will take up inside the system unit. At the same time, it is customary to refer to fans with a thin case for models in which this size does not exceed 20 mm.
Deepcool Maelstrom 120T often compared
Deepcool Maelstrom 240T often compared