USA
Catalog   /   Computing   /   Components   /   Computer Cooling

Comparison Deepcool Maelstrom 240T vs Deepcool Maelstrom 120K

Add to comparison
Deepcool Maelstrom 240T
Deepcool Maelstrom 120K
Deepcool Maelstrom 240TDeepcool Maelstrom 120K
from $85.96 
Outdated Product
from $62.34 up to $66.36
Outdated Product
TOP sellers
Main
Waterblock lighting.
Main specs
Featuresfor CPUfor CPU
Product typeliquid coolingliquid cooling
Fan
Number of fans21
Fan size120 mm120 mm
Bearinghydrodynamichydrodynamic
Min. RPM600 rpm600 rpm
Max. RPM1800 rpm1800 rpm
Speed controllerauto (PWM)auto (PWM)
Max. air flow83.64 CFM62 CFM
Static pressure3.08 mm H2O1.97 mm H2O
MTBF50 K hours30 K hours
Max. TDP150 W150 W
replaceable
Lighting
Min noise level18 dB18 dB
Noise level34 dB32 dB
Radiator
Heatsink materialaluminium
aluminium /copper water block/
Socket
AMD AM2/AM3/FM1/FM2
AMD AM4
 
Intel 1150
Intel 1155/1156
Intel 1366
Intel 2011 / 2011 v3
Intel 2066
Intel 1151 / 1151 v2
Intel 1200
AMD AM2/AM3/FM1/FM2
 
Intel 775
Intel 1150
Intel 1155/1156
Intel 1366
Intel 2011 / 2011 v3
Intel 2066
Intel 1151 / 1151 v2
Intel 1200
Liquid cooling system
Heatsink size240 mm120 mm
Pump size70x86x32 mm70x86x32 mm
Pump rotation speed2400 rpm2200 rpm
Pump MTBF120 K hours120 K hours
Pipe length300 mm300 mm
General
Power source4-pin4-pin
Mount typebilateral (backplate)bilateral (backplate)
Dimensions
274x120x27 mm /radiator/
154x120x27 mm /radiator/
Weight1100 g756 g
Added to E-Catalognovember 2017december 2014

Number of fans

The number of fans in the design of the cooling system. More fans provide higher efficiency (all else being equal); on the other hand, the dimensions and the noise generated during operation also increase accordingly. Also, note that other things being equal, a smaller number of large fans is considered more advanced than numerous small ones; see "Fan diameter" for details.

Max. air flow

The maximum airflow that a cooling fan can create; measured in CFM — cubic feet per minute.

The higher the CFM number, the more efficient the fan. On the other hand, high performance requires either a large diameter (which affects the size and cost) or high speed (which increases the noise and vibration levels). Therefore, when choosing, it makes sense not to chase the maximum air flow, but to use special formulas that allow you to calculate the required number of CFM depending on the type and power of the cooled component and other parameters. Such formulas can be found in special sources. As for specific numbers, in the most modest systems, the performance does not exceed 30 CFM, and in the most powerful systems it can be up to 80 CFM and even more.

It is also worth considering that the actual value of the air flow at the highest speed is usually lower than the claimed maximum; see Static Pressure for details.

Static pressure

The maximum static air pressure generated by the fan during operation.

This parameter is measured as follows: if the fan is installed on a blind pipe, from which there is no air outlet, and turned on for blowing, then the pressure reached in the pipe will correspond to the static one. In fact, this parameter determines the overall efficiency of the fan: the higher the static pressure (ceteris paribus), the easier it is for the fan to “push” the required amount of air through a space with high resistance, for example, through narrow slots of a radiator or through a case full of components.

Also, this parameter is used for some specific calculations, however, these calculations are quite complex and, usually, are not necessary for an ordinary user — they are associated with nuances that are relevant mainly for computer enthusiasts. You can read more about this in special sources.

MTBF

The total time that a cooling fan is guaranteed to run before it fails. Note that when this time is exhausted, the device will not necessarily break — many modern fans have a significant margin of safety and are able to work for some more period. At the same time, it is worth evaluating the overall durability of the cooling system according to this parameter.

Lighting

The presence of its own illumination in the design of the cooling system.

The backlight serves a purely aesthetic function — it gives the device a stylish appearance that blends well with other components in the original design. Thanks to this, such cooling systems are especially appreciated by gamers and fans of external PC modding — especially since the lighting can be different, and the most advanced models even provide backlight synchronization with other components (see below). On the other hand, this function does not affect the efficiency and performance, and the overall cost is inevitably affected, sometimes quite noticeably. Therefore, if the appearance does not play a fundamental role for you, the best choice, most likely, will be a cooling system without backlight.

Noise level

The standard noise level generated by the cooling system during operation. Usually, this paragraph indicates the maximum noise during normal operation, without overloads and other "extreme".

Note that the noise level is indicated in decibels, and this is a non-linear value. So it is easiest to evaluate the actual loudness using comparative tables. Here is a table for values found in modern cooling systems:

20 dB — barely audible sound (quiet whisper of a person at a distance of about 1 m, sound background in an open field outside the city in calm weather);
25 dB — very quiet (normal whisper at a distance of 1 m);
30 dB — quiet (wall clock). It is this noise that, according to sanitary standards, is the maximum allowable for constant sound sources at night (from 23.00 to 07.00). This means that if the computer is planned to sit at night, it is desirable that the volume of the cooling system does not exceed this value.
35 dB — conversation in an undertone, sound background in a quiet library;
40 dB — conversation, relatively quiet, but already in full voice. The maximum permissible noise level for residential premises in the daytime, from 7.00 to 23.00, according to sanitary standards. However, even the noisiest cooling systems usually do not reach this indicator, the maximum for such equipment is about 38 – 39 dB.

Socket

Socket type - socket for CPU - with which the corresponding cooling system is compatible.

Different sockets differ not only in compatibility with a particular CPU, but also in the configuration of the seat for the cooling system. So, when purchasing a processor cooling system separately, you should make sure that it is compatible with the socket. Nowadays, solutions are produced mainly for the following types of sockets: AMD AM2/AM3/FM1/FM2, AMD AM4, AMD AM5, AMD TR4/TRX4, Intel 775, Intel 1150, Intel 1155/1156, Intel 1366, Intel 2011/2011 v3, Intel 2066, Intel 1151/1151 v2, Intel 1200, Intel 1700.

Heatsink size

The nominal size of the radiator provided in the water cooling system.

The radiator provides cooling of the heated coolant coming from the cooled components of the system. It most often works on the principle of a cooler — that is, it consists of the actual radiator and one or more fans. The size of the radiator is indicated by one number — by the largest dimension, length. And the width (on which the working area and, accordingly, efficiency depends) can be determined based on the length. The fact is that radiators use fans of two diameters — 120 and 140 mm; if there are several such fans, they are installed in a row. This means that the length of the structure will necessarily be a multiple of the fan diameter — 120 or 140 mm, and the width will correspond to this diameter. For example, a 120mm or 140mm product would have the same width and one fan, while a 240mm product would have two 120mm fans.

The described features lead to the fact that a larger size does not necessarily mean a more advanced design. So, a 360mm or even 420 mm radiator with three small fans can have the same or even lower efficiency than a 280mm model. In addition, we recall that larger fans with the same performance are slower, and therefore quieter.

Also, the size o...f the radiator must be taken into account when looking for a seat in the case for it. Be aware of the width as well: 140mm fan heatsinks are usually not compatible with 120mm fan heatsink slots. So, a 140 mm model will not fit in a 240 mm (2x120 mm) socket, and 280 mm (2x140 mm) will not fit under 360 mm (3x120 mm), although formally the size seems to be enough in both cases.

Pump rotation speed

The speed at which the working part of the pump rotates, which is nominally provided in the water cooling system.

High speed, on the one hand, has a positive effect on performance, on the other hand, it increases the noise level and reduces the time between failures. Therefore, with the same performance, relatively “slow” pumps are considered more advanced, in which the necessary pumping volumes are achieved due to the large diameter of the working part, and not due to speed.
Deepcool Maelstrom 240T often compared
Deepcool Maelstrom 120K often compared