USA
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Boilers

Comparison Atem Zhytomyr-M AOGV-5 SN 5 kW vs TermoBar KS-GS-5S 5 kW

Add to comparison
Atem Zhytomyr-M AOGV-5 SN 5 kW
TermoBar KS-GS-5S 5 kW
Atem Zhytomyr-M AOGV-5 SN 5 kWTermoBar KS-GS-5S 5 kW
from $160.00 up to $180.36
Outdated Product
from $158.15 up to $184.36
Outdated Product
TOP sellers
Energy sourcegasgas
Installationparapetparapet
Typesingle-circuit (heating only)single-circuit (heating only)
Heating area40 m²40 m²
Technical specs
Heat output5 kW5 kW
Power supply230 V230 V
Coolant min. T40 °С
Coolant max. T90 °С80 °С
Consumer specs
Circulation pump
Boiler specs
Efficiency90 %90 %
Combustion chamberclosed (turbocharged)closed (turbocharged)
Inlet gas pressure13 mbar13 mbar
Max. gas consumption0.3 m³/h0.56 m³/h
Connections
Gas supply1/2"1/2"
Central heating flow1 1/2"
Central heating return1 1/2"
Safety
Safety systems
gas pressure drop
water overheating
flame loss
draft control
gas pressure drop
water overheating
flame loss
draft control
More specs
Dimensions (HxWxD)590x310x325 mm565x400x260 mm
Weight34.5 kg40 kg
Added to E-Catalogaugust 2014august 2014

Coolant min. T

The minimum operating temperature of the heat medium in the boiler system when operating in heating mode.

Coolant max. T

The maximum operating temperature of the heat medium in the boiler system when operating in heating mode.

Max. gas consumption

Maximum gas consumption in the boiler with the corresponding energy source (see above). Achieved when the gas heater is operating at full capacity; with reduced power and consumption, respectively, will be lower.

Note that boilers of the same power may differ in gas consumption due to the difference in efficiency. While the more fuel-efficient models tend to cost more, the price difference pays off in gas savings.

Central heating flow

The diameter of the pipe for connecting the pipe through which the heated water enters the heating system from the boiler.

Diameters are indicated in inches. In some cases, it is allowed to connect a pipe of a different diameter through an adapter, but the best option is still a match in size. Among which models stand out for 3/4", 1", 1 1/4" and 1 1/2".

Central heating return

The diameter of the pipe for connecting the pipe through which the cooled water returns from the heating system to the boiler.

Diameters are indicated in inches. In some cases, it is allowed to connect a pipe of a different diameter through an adapter, but the best option is still a match in size.