USA
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Boilers

Comparison Danko 15 15 kW vs Atem Zhytomyr-3 KS-G-015 SN 16 kW

Add to comparison
Danko 15 15 kW
Atem Zhytomyr-3 KS-G-015 SN 16 kW
Danko 15 15 kWAtem Zhytomyr-3 KS-G-015 SN 16 kW
from $223.16 up to $279.24
Outdated Product
from $234.00 up to $287.44
Outdated Product
TOP sellers
Energy sourcegasgas
Installationfloorfloor
Typesingle-circuit (heating only)single-circuit (heating only)
Heating area120 m²120 m²
Technical specs
Heat output15 kW16 kW
Power supply230 V230 V
Coolant min. T40 °С
Coolant max. T90 °С90 °С
Heating circuit max. pressure1 bar
Consumer specs
Circulation pump
Boiler specs
Efficiency92 %92 %
Combustion chamberopen (atmospheric)open (atmospheric)
Flue diameter110 mm
Inlet gas pressure13 mbar13 mbar
Max. gas consumption1.7 m³/h1.77 m³/h
Connections
Gas supply1/2"1/2"
Central heating flow2"1 1/2"
Central heating return2"1 1/2"
Safety
Safety systems
gas pressure drop
water overheating
flame loss
draft control
gas pressure drop
water overheating
flame loss
draft control
More specs
Dimensions (HxWxD)850x275x540 mm860x285x535 mm
Weight64 kg60 kg
Added to E-Catalogdecember 2013february 2013

Heat output

It is the maximum useful power of the boiler.

The ability of the device to heat a room of a particular area directly depends on this parameter; by power, you can approximately determine the heating area, if this parameter is not indicated in the specs. The most general rule says that for a dwelling with a ceiling height of 2.5 – 3 m, at least 100 W of heat power is needed to heat 1 m2 of area. There are also more detailed calculation methods that take into account specific factors: the climatic zone, heat gain from the outside, design features of the heating system, etc.; they are described in detail in special sources. Also note that in dual-circuit boilers (see "Type"), part of the heat generated is used to heat water for the hot water supply; this must be taken into account when evaluating the output power.

It is believed that boilers with a power of more than 30 kW must be installed in separate rooms (boiler rooms).

Coolant min. T

The minimum operating temperature of the heat medium in the boiler system when operating in heating mode.

Heating circuit max. pressure

The maximum pressure in the heating circuit of the boiler, at which it remains operational, and there is no risk of physical damage to the structure. For a heating system, the maximum pressure is usually about 3 bar, and for a domestic hot water circuit up to 10 bar. When the maximum pressure is exceeded, a safety valve is activated, and part of the water is discharged from the system until a normal pressure level is reached.

Flue diameter

The diameter of the pipe through which combustion products are discharged from the combustion chamber.

In boilers with a closed combustion chamber often used the coaxial flue, consisting of two pipes nested one inside the other. At the same time, products of combustion are discharged from the combustion chamber through the inner pipe, and the air is supplied through the gap between the inner and outer ones. For such flues, the diameter is usually shown in the form of two numbers — the diameter of the inner and outer pipes, respectively. The most popular values are 60/100, 80/80 and 80/125. Non-coaxial flues can be 100, 110, 125, 130, 140, 150, 160, 180 and 200 mm.

Max. gas consumption

Maximum gas consumption in the boiler with the corresponding energy source (see above). Achieved when the gas heater is operating at full capacity; with reduced power and consumption, respectively, will be lower.

Note that boilers of the same power may differ in gas consumption due to the difference in efficiency. While the more fuel-efficient models tend to cost more, the price difference pays off in gas savings.

Central heating flow

The diameter of the pipe for connecting the pipe through which the heated water enters the heating system from the boiler.

Diameters are indicated in inches. In some cases, it is allowed to connect a pipe of a different diameter through an adapter, but the best option is still a match in size. Among which models stand out for 3/4", 1", 1 1/4" and 1 1/2".

Central heating return

The diameter of the pipe for connecting the pipe through which the cooled water returns from the heating system to the boiler.

Diameters are indicated in inches. In some cases, it is allowed to connect a pipe of a different diameter through an adapter, but the best option is still a match in size.
Atem Zhytomyr-3 KS-G-015 SN often compared