USA
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Boilers

Comparison Hotpoint-Ariston Alteas One+ Net 24 24.4 kW vs Protherm Panther 25 KTV 24.6 kW

Add to comparison
Hotpoint-Ariston Alteas One+ Net 24 24.4 kW
Protherm Panther 25 KTV 24.6 kW
Hotpoint-Ariston Alteas One+ Net 24 24.4 kWProtherm Panther 25 KTV 24.6 kW
Outdated Product
from $626.37 up to $696.08
Outdated Product
TOP sellers
Main
The new generation of the Alteas One series. Smartphone or PC control.
Undemanding to water hardness and gas quality. Comfort function. Informative LCD display.
Energy sourcegasgas
Installationwallwall
Typedual-circuit (heating and DHW)dual-circuit (heating and DHW)
Heating area195 m²184 m²
Condensing
Technical specs
Heat output24.4 kW24.6 kW
Min. heat output2.5 kW8.4 kW
Power supply230 V230 V
Power consumption80 W147 W
Rated current0.4 А
Coolant min. T35 °С38 °С
Coolant max. T82 °С80 °С
Heating circuit max. pressure3 bar3 bar
DHW circuit max. pressure7 bar10 bar
Consumer specs
DHW min. T36 °С38 °С
DHW max. T60 °С60 °С
Performance (ΔT=25°C)15.4 L/min
Performance (ΔT ~30 °C)11 L/min12 L/min
Wi-Fi
"Summer" mode
Warm start
Circulation pump
Control busBus BridgeNet
Programmable thermostat
Boiler specs
Efficiency107.3 %92.8 %
Combustion chamberclosed (turbocharged)closed (turbocharged)
Flue diameter60/100 mm
60/100 mm /80/80 for split flue/
Inlet gas pressure20 mbar
Max. gas consumption2.75 m³/h2.8 m³/h
Expansion vessel capacity8 L7 L
Expansion vessel pressure1 bar3 bar
Heat exchangercopper
Connections
Mains water intake1/2"3/4"
DHW flow1/2"3/4"
Gas supply3/4"3/4"
Central heating flow3/4"3/4"
Central heating return3/4"3/4"
Safety
Safety systems
gas pressure drop
water overheating
flame loss
draft control
 
water circulation failure
frost protection
gas pressure drop
water overheating
flame loss
draft control
power outage
 
frost protection
More specs
Glass panel
Dimensions (HxWxD)770x400x315 mm740x410x311 mm
Weight32 kg37 kg
Added to E-Catalogmarch 2023november 2010

Heating area

A very conditional parameter that slightly characterizes the purpose based on the size of the room. And depending on the height of the ceilings, layout, building design and equipment, actual values may differ significantly. However, this item represents the maximum recommended area of the room that the boiler can effectively heat. However, it is worth considering that different buildings have different thermal insulation properties and modern buildings are much “warmer” than 30-year-old and especially 50-year-old houses. Accordingly, this item is more of a reference nature and does not allow us to fully assess the actual heated area. There is a formula by which you can derive the maximum heating area, knowing the useful power of the boiler and the climatic conditions in which it will be used; For more information on this, see "Useful Power". In our case, the heating area is calculated using the formula “boiler power multiplied by 8”, which is approximately equivalent to use in houses that are several decades old.

Condensing

Boilers generate additional heat by condensing water vapour from combustion products. In such units, the combustion gases, before entering the flue, are passed through an additional heat exchanger, in which they are cooled, and the water vapour condenses and transfers thermal energy to the coolant. It allows you to increase the efficiency by 10 – 15% compared to boilers of the classical design — up to the fact that in many similar models, the efficiency exceeds 100% (for more details, see "Efficiency").

The condensation principle of operation is most often found in gas models (see "Power source"); however, solid and liquid fuel boilers with this feature are also produced.

Heat output

It is the maximum useful power of the boiler.

The ability of the device to heat a room of a particular area directly depends on this parameter; by power, you can approximately determine the heating area, if this parameter is not indicated in the specs. The most general rule says that for a dwelling with a ceiling height of 2.5 – 3 m, at least 100 W of heat power is needed to heat 1 m2 of area. There are also more detailed calculation methods that take into account specific factors: the climatic zone, heat gain from the outside, design features of the heating system, etc.; they are described in detail in special sources. Also note that in dual-circuit boilers (see "Type"), part of the heat generated is used to heat water for the hot water supply; this must be taken into account when evaluating the output power.

It is believed that boilers with a power of more than 30 kW must be installed in separate rooms (boiler rooms).

Min. heat output

The minimum heat output at which the heating boiler can operate in constant mode. Operation at minimum power allows you to reduce the number of on-and-off cycles that adversely affect the durability of heating boilers.

Power consumption

The maximum electrical power consumed by the boiler during operation. For non-electric models (see Energy source), this power is usually low, as it is required mainly for control circuits and it can be ignored. Regarding electric boilers, it is worth noting that the power consumption in them is most often somewhat higher than the useful one since part of the energy is inevitably dissipated and not used for heating. Accordingly, the ratio of useful and consumed power can be used to evaluate the efficiency of such a boiler.

Rated current

The current consumed by the electric boiler (see "Power source") during normal operation.

This parameter directly depends on the power. It is required primarily for organizing the connection: wiring and automation must safely deal with the current consumed by the unit.

Coolant min. T

The minimum operating temperature of the heat medium in the boiler system when operating in heating mode.

Coolant max. T

The maximum operating temperature of the heat medium in the boiler system when operating in heating mode.

DHW circuit max. pressure

The maximum pressure in the hot water circuit (DHW) at which it can operate for a long time without failures and damage. See "Heating circuit maximum pressure".
Hotpoint-Ariston Alteas One+ Net 24 often compared
Protherm Panther 25 KTV often compared