Hotpoint-Ariston BLU1 R 100V 1.5K PL DRY
Electrolux EWH 100 Formax
Hotpoint-Ariston BLU1 R 100V 1.5K PL DRYElectrolux EWH 100 Formax
Outdated Product
from $204.00 up to $209.04
Outdated Product
TOP sellers
Main
The proprietary technology of non-mixing cold and hot water NANOMIX is used.
Typestoragestorage
Energy sourcemainsmains
Installationverticalvertical
Tank volume100 L100 L
Tank shapecylindricalrectangular
Technical specs
Power source230 V230 V
Power consumption1500 W
2000 W /1200/800 Вт/
Heating modes3
Max. water temperature75 °C75 °C
Tank liningenamelenamel
Water supplywith pressurewith pressure
Heating time199 min
219 min /when heated up to 75°C/
Magnesium anode
Heating elements22
Heating element type
dry heater /2 по 750 Вт/
dry heater
Features
Functions
thermostat
thermostat
Safety systems
overheat protection
electrical protection (RCD)
safety valve
overheat protection
electrical protection (RCD)
safety valve
General specs
Controlsmechanicalmechanical
Controls layoutbottomfront
Pipe connectionbottombottom
Tank manufacturer's warranty5 years7 years
Dimensions (HxWxD)90x45x48 cm87.9x45.4x46.9 cm
Weight24 kg31 kg
Added to E-Catalogdecember 2019july 2013

Tank shape

The shape of the water heater.

The traditional options are cylindrical and rectangular, but nowadays there are more specific options — flat cases, slim cylindrical devices. Here are the features of each of these options:

— Cylindrical. This form is traditional for storage water heaters. It is because with the same total volume, less material is needed for a cylindrical tank than for a rectangular one; and in production, such tanks are simple and cheap, which allows them to be used in water heaters of any price category. The disadvantages of this form include, first of all, some bulkiness in comparison with other options.

— Rectangular. The case is rectangular in shape, with pronounced front and side faces; the corners can be both sharply defined and rounded. It is the traditional form for instant water heaters, primarily gas, but it can be found in a fairly large number of storage models. Accordingly, the features of a rectangular case will be different — depending on the type of heater. So, in instant water heaters, the “rectangle” is simply one of the most convenient options in terms of the overall layout. But in storage water heaters, this shape differs from the flat one (see below) only with a slightly greater thickness and, in some cases, pronounced angles.

— Flat. A variant found mainly in s...torage electric heaters. Such devices look as if the classic cylindrical body was flattened at the back and front, reducing its thickness by increasing the width (and sometimes height). Thus, such a boiler does not protrude as much in front of the wall as a cylindrical one; in some cases, this point may be fundamental — for example, when installed in a bathroom, where a cylindrical device would hang over the toilet bowl, creating discomfort.

— Slim. A variety of cylindrical cases are characterized by a reduced diameter. In other words, boilers from this category are also round, but with the same volume, they have a noticeably smaller width and thickness than traditional cylindrical ones. In cramped conditions, this can be very useful. However, it must be borne in mind that the price for reducing the diameter is an increase in height.

Power consumption

Electrical power consumed by the heater during operation.

This parameter is of key importance for electric models (see "Energy source"). In them, the power consumption corresponds to the power of the heating element and, accordingly, the heat output of the entire device. The overall efficiency and flow rate of the water heater directly depend on the useful power. Accordingly, high-flow rate models inevitably have high consumption. At the same time, we note that the heating power is selected by the designers in such a way as to guarantee the necessary flow rate and water temperature. So when choosing a device according to flow rate, you need to look primarily at flow rate and temperature. Power must be taken into account when connecting: for example, if a 220 V model (see "Power source") consumes more than 3.5 kW, it, as a rule, cannot be plugged into a regular outlet — connection is required according to special rules. And the most productive and high-powered models — 10 kW or more — are connected only to three-phase mains.

The power consumption has a similar value for combined boilers — adjusted for the fact that in them the electric heater is an additional source of heat. For gas and indirect models, this parameter describes the power consumption of control circuits and other auxiliary structural elements; this power consumption is usually very small — on the order of several tens of watts, less often up to 1.5 kW.

Heating modes

The number of heating modes provided in the device.

This parameter is specified only for models with several heating modes. We emphasize that you should not confuse such functionality with temperature control (see "Features"). The heating mode is the general format of the device; these formats differ primarily in such parameters as the actual heating power, the number (and in combined models, and types) of the heating elements involved, etc. The thermostat, if it is in the design, allows you to change the temperature within a specific mode.

In general, the presence of several heating modes expands the functionality of the water heater but affects its cost. Of course, the specific features of these modes do not hurt to clarify in advance before buying.

Heating time

Time to heat the storage tank (see "Type"), filled with cold water, to operating temperature.

It is worth remembering that this characteristic is not 100% accurate. Manufacturers usually indicate the heating time for certain conditions: a filled tank, maximum heating intensity, and temperature rise (∆T) by a certain number of degrees. In practice, the heating time may differ, both one way and the other. For example, if the heating time for the device is 20 minutes at ∆T = 50 °C, then when the water is heated from 15 °C to 60 °C, the time will be shorter (∆T = 45 °C). Nevertheless, this indicator allows us to evaluate the overall flow rate of the boiler, and with equal ∆T and volumes, different models can be compared in terms of heating time.

Controls layout

Location of heater controls. It is worth choosing by this parameter, taking into account where it is planned to install the device and from which side access to it will be most convenient. For example, when installed in cramped conditions, the water heater can only be opened from the side or the bottom; for such cases, it is worth looking for a model with the appropriate location of the controls.

Tank manufacturer's warranty

The warranty period declared by the manufacturer for the storage water heater tank (see “Type”).

This parameter is important for the reasons of maintenance terms. The tank is the most complex element: other parts of the water heater are relatively easy to repair and change, and if there is a problem with the tank, it is often easier to replace the entire boiler. In the most advanced models, the warranty on the tank can be 10 years or more.

Weight

The weight of the device, excluding the water collected (passing) into it.
Hotpoint-Ariston BLU1 R PL DRY often compared