USA
Catalog   /   Home & Renovation   /   Electrical Equipment   /   UPS

Comparison APC Back-UPS 950VA BX950MI-GR 950 VA vs APC Back-UPS 950VA BX950MI 950 VA

Add to comparison
APC Back-UPS 950VA BX950MI-GR 950 VA
APC Back-UPS 950VA BX950MI 950 VA
APC Back-UPS 950VA BX950MI-GR 950 VAAPC Back-UPS 950VA BX950MI 950 VA
from $166.75 
Expecting restock
from $151.07 
Expecting restock
TOP sellers
Main
Interactive UPS. impulse protection. Quiet work.
Typesmartsmart
Form factorstandard (Tower)standard (Tower)
Full load operating time0.48 min0.48 min
Half load operating time6.7 min6.7 min
Switching to battery6 ms6 ms
Input
Input voltage1 phase (230V)1 phase (230V)
Input voltage range140 – 300 V140 – 300 V
Max. current4 A4 A
Input frequency45 – 65 Hz45 – 65 Hz
Bypass (direct connection)is absentis absent
Output
Output voltage1 phase (230V)1 phase (230V)
Max. output power950 VA950 VA
Rated output power520 W520 W
Output waveformsimilar to a sinusoid (approximated)similar to a sinusoid (approximated)
Output frequency50/60 Hz50/60 Hz
Redundant sockets4
Socket typetype F (Schuko)
Reserved C13/C14 connectors6
Battery
Battery typelead acid
Supplied battery(s) capacity9 Ah9 Ah
Voltage of the 1 battery in set12 V
Batteries11
Full charge time480 min480 min
Protection
Protection
short circuit protection
overload protection
noise filtering
data line protection
sound alarm
short circuit protection
overload protection
noise filtering
data line protection
sound alarm
Fuseautomelting
Surge protection273 J273 J
Control interfaces
USB
USB
General
Operating temperature0 – 40 °C0 – 40 °C
Noise level40 dB40 dB
Dimensions (HxWxD)160x120x355 mm160x120x355 mm
Weight6.1 kg6.1 kg
Added to E-Catalogfebruary 2021february 2021

Redundant sockets

The number of outlets connected to the power reserve(battery) provided in the design of the UPS. In order for the UPS to fulfill its main role (providing a backup power in case of power outages), the corresponding electrical appliances must be connected to these outlets. The sockets have a standard shape and are compatible with the vast majority of popular 230 V plugs.

At a minimum, the UPS has 1 or 2 outlets and, in more advanced ones, there may be 3 or more.

Socket type

A socket for a specific type of plug in the UPS design.

Type F (Schuko). A traditional European socket with two round holes in the center and grounding contacts in the form of two metal brackets (at the top and bottom of the socket). The term Schuko stuck to this type of socket due to the abbreviation from the German Schutzkontakt - protective contact.

Type E (French). The French style socket has two round holes and a protruding ground pin just above them in the center. The standard has become widespread in France, Poland and Belgium (along with the traditional type F sockets).

Type G (British). The plug for such sockets consists of two flat horizontal pins and one flat vertical pin for grounding. The standard is found mainly in the countries of the United Kingdom, Malta, Cyprus, Singapore and Hong Kong.

Type B (American). American-style sockets are designed for plugs with two flat prongs and a semicircular grounding contact. Type B is widely used in regions with voltage 110 - 127 V - USA, Japan, Saudi Arabia, etc.

Reserved C13/C14 connectors

Number of C13/C14 connectors with power reserve provided in the UPS design.

Electrical appliances connected to connectors with a reserve are insured against a power failure in the network - in this case they switch to the battery. The C13/C14 connector itself is also known as a “computer socket”; it supplies the same 230 V as a regular household network, but is not compatible with plugs for traditional sockets, because uses three flat contacts. However, there are adapters between these standards.

At a minimum, the UPS is provided with 1, 2 or 3 C13/C14 connectors for one workstation. In more advanced, so to speak office ones, the number of C13/C14 connectors may be greater - 4 ports, 6 connectors, 8 and even more

Battery type

- Lead acid. Structurally, lead-acid batteries are based on a combination of electrodes made of lead compounds immersed in a liquid electrolyte, the role of which is played by an aqueous solution of sulfuric acid. The advantages of this type are simplicity and low cost, low self-discharge, no "memory effect" and maintaining performance in a wide temperature range. At the same time, the less charge remains in such batteries, the less current they produce. Also, lead-acid batteries are afraid of deep discharges, take a long time to charge, have large dimensions and weight in the context of other types.

- Lead-acid (AGM). An advanced type of lead-acid battery with an electrolyte in a jelly-like state. The gel electrolyte provides maximum contact with the negative and positive plates while maintaining a uniform consistency throughout the volume. AGM batteries impress with their high reliability, low self-discharge, deep discharge resistance and long service life. However, they are sensitive to charge quality, short circuits and negative temperatures.

— Li-Ion. Lithium-ion batteries have a high capacity with small dimensions and weight. They are not subject to the “memory effect”, they are able to charge quite quickly, they can boast of an excellent reserve for charge-discharge cycles. Li-Ion batteries also have disadvantages - first of all, it is sensitivity to low or high temperatures, and when overloaded, such a battery can catch fire or even explode. Howeve...r, due to the use of embedded controllers, the likelihood of such "accidents" is extremely small and, in general, the advantages of this technology significantly outweigh the disadvantages.

Voltage of the 1 battery in set

The value of the operating voltage of one complete battery. In most cases, it is 12 V, UPS with 24-volt batteries is a little less common.

Fuse

Fuses are used to protect the UPS from a critical increase in current strength: at the right time, they open the circuit, preventing unpleasant consequences. Today, these types of fuses are used.

— Melting. At a critical current strength, the conductive element in such a fuse melts and opens the circuit. The fusible protection is disposable, after operation such a fuse must be replaced.

— Automatic. Such a fuse has a sensor that monitors the current strength and opens the contacts at the right time. Its main difference from fusible is reusability: after operation, the circuit can be closed again with literally one press of the button on the fuse.
APC Back-UPS 950VA BX950MI-GR often compared