Dark mode
USA
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Boilers

Comparison boilers

Save List
Add to comparison
Italtherm CITY CLASS 25 F 24 kW
Protherm Puma Condens 18/24 MKV-AS/1 20 kW
Protherm Gepard 23 MOV 23 kW
Beretta CITY 24 CSI 24 kW 230 V
Hotpoint-Ariston Clas X 24 CF 23.7 kW 230 V
Immergas EOLO Star 24-4 E 23.8 kW 230 V
Italtherm CITY CLASS 25 F 24 kWProtherm Puma Condens 18/24 MKV-AS/1 20 kWProtherm Gepard 23 MOV 23 kWBeretta CITY 24 CSI 24 kW
230 V
Hotpoint-Ariston Clas X 24 CF 23.7 kW
230 V
Immergas EOLO Star 24-4 E 23.8 kW
230 V
Outdated ProductOutdated Product
from $501.83 up to $556.06
Outdated Product
from $396.00 up to $486.16
Outdated Product
from $504.00 up to $603.20
Outdated Product
Outdated Product
User reviews
1
0
1
0
0
0
1
0
0
0
0
1
0
0
0
3
TOP sellers
Energy sourcegasgasgasgasgasgas
Installationwallwallwallwallwallwall
Typedual-circuit (heating and DHW)dual-circuit (heating and DHW)dual-circuit (heating and DHW)dual-circuit (heating and DHW)dual-circuit (heating and DHW)dual-circuit (heating and DHW)
Heating area192 m²160 m²184 m²180 m²190 m²190 m²
Condensing
Technical specs
Heat output24 kW20 kW23 kW24 kW23.7 kW23.8 kW
Min. heat output8.5 kW6.6 kW9.1 kW9.9 kW6.8 kW
Power supply230 V230 V230 V230 V230 V230 V
Power consumption103 W90 W92 W125 W50 W130 W
Coolant min. T35 °С30 °С38 °С40 °С35 °С35 °С
Coolant max. T80 °С75 °С83 °С90 °С82 °С80 °С
Heating circuit max. pressure3 bar3 bar3 bar3 bar3 bar3 bar
DHW circuit max. pressure6 bar10 bar10 bar6 bar6 bar10 bar
Consumer specs
DHW min. T35 °С35 °С38 °С37 °С36 °С35 °С
DHW max. T55 °С55 °С65 °С60 °С60 °С55 °С
Performance (ΔT=25°C)13.7 L/min13.7 L/min14.3 L/min11.1 L/min
Performance (ΔT ~30 °C)11.5 L/min11.4 L/min9.8 L/min10.2 L/min
"Summer" mode
Heated floor mode
Warm start
Circulation pump
Control buseBuseBusBus BridgeNet
Boiler specs
Efficiency93.3 %107.8 %89.5 %91.7 %91.9 %93.4 %
Combustion chamberclosed (turbocharged)closed (turbocharged)open (atmospheric)closed (turbocharged)open (atmospheric)closed (turbocharged)
Flue diameter60/100 mm126 mm60/100 mm130 mm60/100 mm
Inlet gas pressure20 mbar20 mbar20 mbar20 mbar20 mbar13 mbar
Max. gas consumption2.72 m³/h2.54 m³/h2.9 m³/h2.73 m³/h2.73 m³/h2.7 m³/h
Expansion vessel capacity8 L8 L5 L8 L8 L6 L
Expansion vessel pressure1 bar3 bar1 bar1 bar
Coolant performance788 L/h
Heat exchangeraluminiumcopper
Connections
Mains water intake1/2"1/2"1/2"1/2"1/2"1/2"
DHW flow1/2"1/2"1/2"1/2"1/2"1/2"
Gas supply1/2"1/2"3/4"3/4"3/4"3/4"
Central heating flow3/4"3/4"3/4"3/4"3/4"3/4"
Central heating return3/4"3/4"3/4"3/4"3/4"3/4"
Safety
Safety systems
gas pressure drop
water overheating
flame loss
draft control
 
water circulation failure
frost protection
 
water overheating
flame loss
draft control
 
water circulation failure
frost protection
gas pressure drop
water overheating
flame loss
draft control
 
 
frost protection
gas pressure drop
 
flame loss
 
power outage
 
frost protection
gas pressure drop
water overheating
flame loss
draft control
 
water circulation failure
frost protection
gas pressure drop
water overheating
flame loss
draft control
 
water circulation failure
frost protection
More specs
Dimensions (HxWxD)727x400x300 mm626x400x270 mm740x410x310 mm715x405x248 mm770x400x315 mm756x440x240 mm
Weight30 kg25.6 kg33 kg34 kg27 kg29 kg
Added to E-Catalogaugust 2017september 2020july 2011september 2010october 2016november 2017

Articles, reviews, useful tips

All materials
01.2025
Rating boilers (january)
Popularity rating boilers is based on integrated statistics on interest shown by Internet audience
FAQ: 10 frequently asked questions about heating boilers
Answers to common questions in the section "heating boilers"
Common error codes for gas heating boilers
The error codification system allows you to identify the essence of the problem and determine ways to quickly solve it
How to get through the winter: autonomous house
Autonomous sources of electricity, heat and hot water to comfortably get through the winter