USA
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Boilers

Comparison boilers

Save List
Add to comparison
BAXI Duo-Tec Compact E 24 20.6 kW
Protherm Puma Condens 18/24 MKV-AS/1 20 kW
Hotpoint-Ariston Clas X 24 CF 23.7 kW 230 V
BAXI Eco-4s 24 24 kW 230 V
Italtherm CITY CLASS 25 F 24 kW
Thermex EUROSTYLE F24 24 kW 230 V
BAXI Duo-Tec Compact E 24 20.6 kWProtherm Puma Condens 18/24 MKV-AS/1 20 kWHotpoint-Ariston Clas X 24 CF 23.7 kW
230 V
BAXI Eco-4s 24 24 kW
230 V
Italtherm CITY CLASS 25 F 24 kWThermex EUROSTYLE F24 24 kW
230 V
Outdated ProductOutdated Product
from $504.00 up to $603.20
Outdated Product
from $482.56 up to $486.20
Outdated Product
Outdated ProductOutdated Product
Energy sourcegasgasgasgasgasgas
Installationwallwallwallwallwallwall
Typedual-circuit (heating and DHW)dual-circuit (heating and DHW)dual-circuit (heating and DHW)dual-circuit (heating and DHW)dual-circuit (heating and DHW)dual-circuit (heating and DHW)
Heating area165 m²160 m²190 m²192 m²192 m²192 m²
Condensing
Technical specs
Heat output20.6 kW20 kW23.7 kW24 kW24 kW24 kW
Min. heat output3.5 kW6.6 kW9.9 kW9.3 kW8.5 kW
Power supply230 V230 V230 V230 V230 V230 V
Power consumption85 W90 W50 W80 W103 W110 W
Coolant min. T25 °С30 °С35 °С30 °С35 °С35 °С
Coolant max. T80 °С75 °С82 °С85 °С80 °С80 °С
Heating circuit max. pressure3 bar3 bar3 bar3 bar3 bar3 bar
DHW circuit max. pressure8 bar10 bar6 bar8 bar6 bar8 bar
Consumer specs
DHW min. T35 °С35 °С36 °С35 °С35 °С35 °С
DHW max. T60 °С55 °С60 °С60 °С55 °С60 °С
Performance (ΔT=25°C)13.8 L/min14.3 L/min13.7 L/min13.7 L/min13.6 L/min
Performance (ΔT ~30 °C)11.5 L/min10.2 L/min9.8 L/min
Wi-Fi
"Summer" mode
Heated floor mode
Warm start
Circulation pump
Control busOpenThermeBusBus BridgeNet
Programmable thermostat
Boiler specs
Efficiency
108.8 % /at 30% power/
107.8 %91.9 %91.2 %93.3 %93 %
Combustion chamberclosed (turbocharged)closed (turbocharged)open (atmospheric)open (atmospheric)closed (turbocharged)closed (turbocharged)
Flue diameter60/100, 80/80 mm130 mm120 mm
60/100 mm /80/80 for split flue/
60/100 mm /80/80 mm for separate/
Inlet gas pressure20 mbar20 mbar20 mbar
Max. gas consumption2.61 m³/h2.54 m³/h2.73 m³/h2.78 m³/h2.72 m³/h
Expansion vessel capacity7 L8 L8 L6 L8 L6 L
Expansion vessel pressure0.8 bar0.5 bar1 bar1 bar
Coolant performance788 L/h
Heat exchangersteelaluminiumcopper
Connections
Mains water intake1/2"1/2"1/2"1/2"1/2"1/2"
DHW flow1/2"1/2"1/2"1/2"1/2"1/2"
Gas supply1/2"1/2"3/4"3/4"1/2"1/2"
Central heating flow3/4"3/4"3/4"3/4"3/4"3/4"
Central heating return3/4"3/4"3/4"3/4"3/4"3/4"
Safety
Safety systems
gas pressure drop
water overheating
flame loss
draft control
water circulation failure
frost protection
 
water overheating
flame loss
draft control
water circulation failure
frost protection
gas pressure drop
water overheating
flame loss
draft control
water circulation failure
frost protection
gas pressure drop
water overheating
flame loss
draft control
water circulation failure
frost protection
gas pressure drop
water overheating
flame loss
draft control
water circulation failure
frost protection
gas pressure drop
water overheating
flame loss
draft control
water circulation failure
frost protection
More specs
Dimensions (HxWxD)700x400x299 mm626x400x270 mm770x400x315 mm730x400x299 mm727x400x300 mm740x440x235 mm
Weight34 kg25.6 kg27 kg29 kg30 kg
Added to E-Catalogmarch 2021september 2020october 2016august 2016august 2017december 2018

Articles, reviews, useful tips

All materials
11.2024
Rating boilers (november)
Popularity rating boilers is based on integrated statistics on interest shown by Internet audience
How to get through the winter: autonomous house
Autonomous sources of electricity, heat and hot water to comfortably get through the winter
FAQ: 10 frequently asked questions about heating boilers
Answers to common questions in the section "heating boilers"
Common error codes for gas heating boilers
The error codification system allows you to identify the essence of the problem and determine ways to quickly solve it