USA
Catalog   /   Large Appliances   /   Freezers

Comparison Ardesto URM-85M60 60 L vs ARCTIC AMK-088 80 L

Add to comparison
Ardesto URM-85M60 60 L
ARCTIC AMK-088 80 L
Ardesto URM-85M60 60 LARCTIC AMK-088 80 L
Outdated ProductOutdated Product
TOP sellers
Product typefreezerfreezer
Capacity60 L80 L
Number of compartments33
Features
Max. temperature-16 °C
Minimum temperature-24 °C
Power failure autonomy9 h18 h
Freeze capacity6 kg/day4 kg/day
Reversible door
Hidden door handle
More specs
Controlsinternal rotary knobsinternal rotary knobs
Energy classA+A+
Energy consumption per year195 kWh
Climate classN, ST (+16...+38 °С)subtropical ST (+18...+38 °C)
Noise level41 dB41 dB
Dimensions (HxWxD)84.5x44.5x47.5 cm84x57x50 cm
Weight20 kg26 kg
Color
Added to E-Catalogfebruary 2023april 2020

Capacity

It is the total working capacity of the freezer. A larger capacity allows you to accommodate more products but affects the dimensions and cost of the unit. Therefore, when choosing according to this parameter, you should not chase after the maximum capacity but the capacity you really need. For example, the average required capacity is 50 litres per person. And when choosing a display chest freezer (see "Product type"), you need to take into account the number of products offered for sale.

It is also worth considering that the freezer is often divided into several compartments (see below) - which means that a large capacity does not guarantee that large pieces of food can fit in the device.

Max. temperature

The highest temperature maintained by the freezer during normal operation. This parameter is not as important as the minimum freezing temperature, however, it allows to evaluate the optimal conditions for storing certain categories of products that do not need deep freezing. And in some cases, it shows that the freezer can work as a refrigerator.

Minimum temperature

The lowest temperature that the freezer can maintain in normal operation. First of all, the duration of food storage in the freezer depends on this parameter: it is believed that a temperature of -12 ° C is enough to preserve food for a month, -18 ° C – 3 months, -24 ° C – up to a year. At the same time, it must be taken into account that not only temperature affects the shelf life but also the type of product and its quality before freezing.

Power failure autonomy

The amount of time the freezer keeps food cold enough when the refrigeration system is turned off, for example, due to a breakdown or power outage. Technically, the power failure autonomy for each model is calculated differently; For example, for a freezer with an operating temperature of -18 ° C, this is the period during which the products in the chamber heat up from -18 ° C to -9 ° C. To sum up, the time is indicated during which the frozen products are guaranteed not to heat up to a temperature at which they could lose their properties.

Freeze capacity

One of the main indicators of freezer performance is the approximate amount of fresh food that the freezer can completely freeze from room temperature to the minimum operating temperature in 24 hours. For domestic use, a power of 10-15 kg/day is considered quite sufficient. More performant models may be required if you have to freeze a lot of food at a time or for industrial purposes.

Energy consumption per year

It is the average amount of energy consumed by the freezer in a year of operation. Of course, these figures are not absolutely accurate. The actual power consumption may vary depending on the specific operating conditions. However, this parameter makes it possible to evaluate the consumption of the device and compare different models with each other. At the same time, it often turns out to be more convenient and visual than the energy consumption class (see above) because, in this paragraph, we are talking about a specific figure (from which you can also calculate the cost of electricity consumed).

Climate class

The climate class to which the freezer corresponds.

As the name implies, this parameter describes the environmental conditions for which the unit is designed. The warmer it is around, the more powerful the freezer should be and the better thermal insulation it should have. Specific classes are indicated by letters. Here are the most popular options:

— SN (subnormal). Models for a cool temperate climate have an operating range from +10 °C to + 32 °C. Such a unit can be useful in a poorly heated room where the temperature can drop below +16 °C — for example, on the veranda of a private house, in a garage, etc.

— N (normal). Freezer for a temperate climate, with an operating temperature range of +16...+32 °C. Such a unit is suitable for most residential apartments and houses in mid-latitudes.

— ST (subtropical). Models for subtropical and humid tropical climates. Normally they work at the range of external temperatures +18...+38 °C.

— T (tropical). Refrigerators for dry tropical climates. Designed for temperature range +18 °C to +43 °C.

Also, note that there are many models on the market with an extended temperature range covering several classes. For example, a unit labelled N-ST will have a temperature range of +16...+38 °C. These freezers are indispensable in climates, conditions which are not covered by one standard class — for example, in cold winters and hot summers.
Ardesto URM-85M60 often compared