USA
Catalog   /   Computing   /   Networking   /   Switches

Comparison Ubiquiti EdgeSwitch ES-8XP vs Ubiquiti EdgeSwitch 8-150W

Add to comparison
Ubiquiti EdgeSwitch ES-8XP
Ubiquiti EdgeSwitch 8-150W
Ubiquiti EdgeSwitch ES-8XPUbiquiti EdgeSwitch 8-150W
from $389.99 
Expecting restock
Compare prices 5
TOP sellers
Typemanaged 2 level (L2)managed 3 level (L3)
Mountrack-mountrack-mount
Ports
Gigabit Ethernet88
SFP (optics)2
Uplink2
Uplink typeSFP
Console port
Features
Control
SSH
Telnet
Web interface
SNMP
SSH
Telnet
Web interface
SNMP
Basic features
 
VLAN
 
Link Aggregation
VLAN
loop protection
Routing
Static
PoE
PoE (output)passive802.3af/at passive
PoE outputs88
PoE output power
23 W /при 48V/
30 W
Total PoE power140 W
General
PSUbuilt-inbuilt-in
Operating temperature-25 °C ~ +55 °C
Dimensions (WxDxH)210x185x41 mm204x235x43 mm
Weight1240 g1720 g
Added to E-Catalogseptember 2019november 2017

Type

Unmanaged. The simplest kind of switch that does not have, as the name suggests, the ability to manage; and the possibilities of monitoring the state of the device are usually limited to the simplest indicators in the form of light bulbs (power supply, port activity). The advantages of such models are battery life, ease of use and low cost. The main disadvantage of this type is obvious — the impossibility of configuring the operation parameters. Unmanaged switches are well suited for small LANs like a home or small office where little administration tricks are required; but for large organizations they should not be used.

Customizable. This category includes switches that allow you to change some of the operating parameters. At the same time, the possibilities for such changes are much narrower than in managed models, and the matter is usually limited to disabling individual ports, switching standard speeds for Ethernet connectors (for example, from 100 Mbps to 10 Mbps) and simple monitoring tools like browsing the network statistics. In addition, after reconfiguration, the device, usually, needs to be rebooted — in other words, it is impossible to control the operation of the switch on the fly. However, professional models designed for large networks can also belong to this type.

Managed 2 levels. The term "managed" means that the switch has the ab...ility to reconfigure "on the fly" — in contrast to the configurable models described above. In addition, the overall functionality of such devices in most cases is noticeably wider. And "layer 2" means that the device supports only the second layer of the OSI network model — the channel, which is responsible for physical addressing. In fact, this means that the switch is able to work with the MAC addresses of connected devices, but IP addressing is beyond its capabilities.

— Managed 3 levels. A kind of managed switches (see above) that supports the third level of the OSI network model. This layer is responsible for logical addressing and route definition, which allows the device to work with IP addresses. Due to this, models of this type are considered the most advanced, they often provide not only the traditional features for "switches", but also individual functions of routers. On the other hand, the abundance of features significantly affects the price. These switches are commonly used in data centers, telecommunications companies, and other professional networking environments; it hardly makes sense to purchase such a device for a home or small office.

SFP (optics)

The number of optical network ports of the SFP standard provided in the design of the switch. We emphasize that we are talking about "ordinary" SFPs; SFP+ data is usually listed separately.

Specifically, in switches, the marking “SFP” usually means a connector for fiber with a connection speed of 1 Gbps. Technically, this is not much compared to RJ-45 speeds; however, this connection format has a number of advantages. One of the main ones is a greater effective range: the mentioned gigabit standard used in switches works with a cable length of up to 550 m, and by the standards of fiber, this is still very little. True, the cable itself is sensitive to kinks and requires quite delicate handling; on the other hand, it is completely immune to electromagnetic interference. On the other hand, in general, the SFP format is noticeably less popular in network equipment than RJ-45; therefore, there are few ports of this type even in advanced devices. So, solutions for 2 or 4 SFP connectors are most widely used, although there are more - 6, 8, or even 10 or more. It is also worth considering that the so-called combo connectors can be used in switches, combining SFP and RJ-45; the presence of such ports is specified in the notes, they are taken into account both in the calculation of RJ-45 and in the calculation of SFP.

To clarify, Uplink inputs also often use this type of connector; however, their...number is specified separately (see below).

Uplink

The number of Uplink connectors provided in the design of the switch.

“Uplink” in this case is not a type, but a connector specialization: this is the name of the network interface through which the switch (and network devices connected to it) communicate with external networks (including the Internet) or network segments. In other words, this is a kind of "gate" through which all traffic from the network segment served by the switch is transmitted further. Uplink, in particular, can be used to connect to a similar "switch" (for horizontal network expansion) or to a higher level device (like a core switch).

Accordingly, the number of Uplink connectors is the maximum number of external connections that the switch can provide without using additional equipment. The specific type of such a connector may be different, but this is usually one of the varieties of LAN or SFP; see "Uplink type" for details.

Uplink type

The type of connector(s) used in the switch as an Uplink interface.

See above for details on such an interface; here we note that the same network ports are usually used as Uplink, as for connecting individual devices to the switch. Here are the main options for such connectors:

- Fast Ethernet - LAN network connector (for "twisted pair") with support for speeds up to 100 Mbit. Such a speed is considered low by modern standards, while the Uplink port puts forward increased bandwidth requirements - after all, traffic from all devices served by the switch goes through it. Therefore, in this role, Fast Ethernet ports are used mainly in inexpensive and outdated models.

- Gigabit Ethernet - LAN connector with support for speeds up to 1 Gb / s. Such a speed is often enough even for a fairly extensive network, while the connectors themselves are relatively inexpensive.

- 2.5 Gigabit Ethernet - LAN connector with support for speeds up to 2.5 Gbps.

- 10Gigabit Ethernet - LAN connector with support for speeds up to 10 Gbps. Such features allow you to work comfortably even with very large volumes of traffic, but they significantly affect the price of the switch. Therefore, this option is rare, mainly in high-end models.

— SFP. Socket for fiber optic cable that supports speeds of about 1 Gb / s. At the same time, over Gigabit Ethernet, which has a similar bandwidth, this connector has one noticeable advantage - a lon...ger connection range (usually up to 550 m).

- SFP+. An evolution of the SFP standard described above. The switches usually provide a connection speed of 10 Gb / s; like the original standard, it noticeably outperforms an Ethernet connection in terms of effective range. On the other hand, the real need for such speeds does not arise very often, and SFP+ is quite expensive. Therefore, the presence of such Uplink connectors is typical mainly for high-end models with a large number of ports.

— SFP28. Another development of SFP with increased throughput up to 25 Gbps.

— QSFP / QSFP+. The fastest SFPs up to 40 Gbps.

We also note that the connectors described above (except perhaps Fast Ethernet) are rarely used as the only type of Uplink input. Combinations of electrical and fiber optic ports - SFP / Gigabit Ethernet and SFP + / 10Gigabit Ethernet - have become noticeably more common. This provides versatility in connection, allowing you to use the type of cable that is most convenient in a given situation; and if necessary, of course, you can use all Uplink inputs at once. However, it is worth considering that in some models, Ethernet and SFP interfaces can be combined in one physical connector. So before buying this nuance does not hurt to clarify separately.

There are also switches that use a combination of two types of SFP - SFP/SFP+; however, there are few such models and they mainly belong to the professional level.

Basic features

DHCP server. A feature that makes it easy to manage the IP addresses of devices connected to the switch. Without its own IP address, the correct operation of the network device is impossible; and DHCP support allows you to assign these addresses both manually and fully automatically. At the same time, the administrator can set additional parameters for the automatic mode (range of addresses, maximum time for using one address). And even in fully manual mode, work with addresses is performed only by means of the switch itself (whereas without DHCP, these parameters would also have to be specified in the settings of each device on the network).

Stacking support. The ability to operate the device in stack mode. A stack consists of several switches that are perceived by the network as one “switch”, with one MAC address, one IP address, and with a total number of connectors equal to the total number of ports in all involved devices. This feature is useful if you want to build an extensive network that lacks the capabilities of a single switch, but do not want to complicate the topology.

Link Aggregation. Switch support for link aggregation technology. This technology allows you to combine several parallel physical communication channels into one logical one, which increases the speed and reliability of the connection. Simply put, a switch with such a fun...ction can be connected to another device (for example, a router) not with one cable, but with two or even more at once. The increase in speed in this case occurs due to the summation of the throughput of all physical channels; however, the total speed may be less than the sum of the speeds — on the other hand, combining several relatively slow connectors is often cheaper than using equipment with a more advanced single interface. And the increase in reliability is carried out, firstly, by distributing the total load over individual physical channels, and secondly, by means of "hot" redundancy: the failure of one port or cable can reduce the speed, but does not lead to a complete disconnection, and when the channel is restored, the channel is switched on automatically.
Note that both the standard LACP protocol and non-standard proprietary technologies can be used for Link Aggregation (the latter is typical, for example, for Cisco switches). In addition, there are quite a few alternative names for this technology — port trunking, link bundling, etc.; sometimes the difference is only in the name, sometimes there are technical nuances. All these details should be clarified separately.

VLAN. Support of the VLAN function by the switch — virtual local area networks. In this case, the meaning of this function is the ability to create separate logical (virtual) local networks within the physical "local area". Thus, it is possible, for example, to separate departments in a large organization, creating for each of them its own local network. The organization of VLAN allows you to reduce the load on network equipment, as well as increase the degree of data protection.

— Protection against loops. The switch has a loop protection function. The loop in this case can be described as a situation where the same signal is launched in the network in an endless loop. This may be due to incorrect cable connection, the use of redundant links and some other reasons, but anyway, such a phenomenon can “put down” the network, which means it is highly undesirable. Security prevents loops, usually by disabling looped ports.

— Limiting the speed of access. The ability to limit the data exchange rate for individual switch ports. Thus, it is possible to reduce the load on the network and prevent the "clogging" of the channel by individual terminals.

Note that the matter is not limited to this list: other features may be found in modern switches.

Static

Recall that routing is the definition of the best path through which each data packet can be delivered to the recipient. For this, special tables are used, stored in the memory of the control network device with the routing function. According to the method of filling these tables, this procedure is divided into two main varieties — static and dynamic.

Static routing is a method in which all data routes (entries in the routing table) are manually written by the administrator; this applies both to the initial creation of the table and to making changes to it when changes are made to the network configuration. The main advantage of this method is the minimum load on the switch processor, which has a positive effect on the speed and reliability of the network. The main disadvantages of static routing are associated with the need for manual control. So, the larger the network, the more complex and time-consuming it is to manage it; Administrator's inattention can become an additional cause of failures; and diagnosing some problems is noticeably more difficult — for example, if there is a failure at the link layer, the static route remains visible as active, although no data is transmitted.

PoE (output)

The switch supports the Power over Ethernet function.

This feature allows the switch to supply power to network devices over the same Ethernet cable that transmits data. This reduces the number of wires and simplifies power supply, which is especially convenient if the device is installed in a hard-to-reach place where there is no outlet nearby, and it is difficult to pull an additional cable. An example is an IP surveillance camera installed under the ceiling.

The number of PoE outputs may vary. It should also be borne in mind that when several consumers are connected at the same time, specific power restrictions apply; see "Total PoE Power" for details.

Accordingly, such devices are much more expensive than switches without PoE.

PoE output power

The PoE power (see above) provided by the switch to each individual PoE output. This indicator allows you to evaluate whether a particular device can be connected to such an output — the power consumption of the load in peak mode should not exceed the output power of the port. There are three standards EEE 802.3af ( PoE, ~15W), IEEE 802.3at ( PoE+, ~30W) and IEEE 802.3bt ( PoE++, ≥40W)

Note that when connecting several PoE devices at the same time, the total PoE power must also be taken into account — see below for more details.

Total PoE power

The total output power provided by the switch when powering devices using the PoE standard (see above).

This indicator usually corresponds to the sum of the powers of all outputs — that is, the power of one PoE port, multiplied by their total number. However, the power limits for one output and for the entire switch are somewhat different: if a load with a power equal to the output power of the power supply on this connector can be connected to a single connector, then the total power consumption of all devices connected via PoE should ideally not exceed 75% of the total power supply — this gives an additional guarantee in case of malfunctions. In fact, this means that all PoE outputs cannot be used “to the fullest” at the same time. For example, if there are two such outputs, and one is loaded at 100%, then the second can be loaded with a maximum of 50% — the total power consumption in this case will be the same 75% of the total output. Therefore, a large total power is needed when using the device to the maximum.