USA
Catalog   /   Small Appliances   /   Health & Rehabilitation   /   Clinical Thermometers

Comparison Sanitas SFT77 vs Beurer FT 58

Add to comparison
Sanitas SFT77
Beurer FT 58
Sanitas SFT77Beurer FT 58
Outdated Product
from $24.14 
Expecting restock
TOP sellers
Typeinfraredinfrared
Application area
frontal
frontal
Measurements
Air temperatures
Liquid temperatures
Measurement duration1 с2 с
Measurement range0 – 100 °C- 22 – 100 °C
Measurement accuracy0.2 °C0.2 °C
General
Reading memory30 pcs10 pcs
Sound signal
Display backlight
Power source2xAAA2xAAA
Added to E-Catalogmarch 2020june 2016

Measurement duration

The time it takes for a thermometer to provide a temperature reading, from contact or activating the IR sensor to obtaining the result, is crucial for efficiency. Quick measurements save time during temperature checks. However, it's important to mention that for axillary use (see "Application area"), it's advised to keep the thermometer in place for a minimum of 5 minutes, irrespective of the manufacturer's specified measurement time, due to the nature of the procedure.

Measurement range

The range of temperatures that a thermometer can measure.

For measuring body temperature, a range of 35 – 43 °C is considered ample, covering values encountered in individuals with high fever or hypothermia. Although modern medical thermometers may have broader ranges, especially those designed for water and air temperature measurement (e.g., -20 – 100 °C), when used for body temperature, they typically operate within a narrower range. The overall and "solid" measurement ranges are often specified separately in these thermometers.

Reading memory

The number of results the thermometer can store in memory. The ability to "remember" the results of previous measurements can be very convenient in some cases — in particular, it allows you to accurately track changes in temperature over time. The most advanced models are capable of storing several dozen readings in memory.

Sound signal

The presence of a sound signal in the thermometer. Most often, such a signal indicates the end of the measurement, which eliminates the need to independently monitor the time or get a device to check the readings. However, other events can also be accompanied by sounds, such as switching on and off.

Display backlight

Availability of backlight at own display of the thermometer. This feature allows you to easily see the screen readings in low light and even in complete darkness.
Sanitas SFT77 often compared