USA
Catalog   /   Home & Renovation   /   Electrical Equipment   /   Voltage Monitoring Relays

Comparison DigiTOP VP-3F63A vs DigiTOP VP-380V

Add to comparison
DigiTOP VP-3F63A
DigiTOP VP-380V
DigiTOP VP-3F63ADigiTOP VP-380V
Outdated ProductOutdated Product
TOP sellers
Devicevoltage Monitoring Relaysvoltage Monitoring Relays
Voltagevariablevariable
Number of phases33
MountdIN raildIN rail
Width (unit)7 U3 U
Specs
Rated current63 А6 А
Maximum current80 А10 А
Voltage measuring range50 – 400 V50 – 400 V
Measurement accuracy (±)1 %1 %
Cut-off time (lower limit)0.02 с0.02 с
Off time (upper limit)0.02 с0.02 с
Reclosing delay5 – 600 с5 – 600 с
Lower cut-off limit120 – 200 V120 – 200 V
Upper cut-off limit210 – 270 V210 – 270 V
Functions
display
operation indicator
display
 
General
Adjustmentdigitaldigital
Protection levelIP20IP20
Dimensions122.5x90x64 mm
Added to E-Catalogdecember 2017december 2017

Width (unit)

Width expressed in unit units. This unit is used to measure the width of rack-mounted devices and makes it easy to estimate how much space you need. Width in unit is always expressed as whole numbers, 1 unit is approximately equal to 17.5 mm. There are models 1U, 2U, 3U and more

Rated current

Rated switching current for which the control relay is set. In some models, this parameter can be changed at the request of the user; for such devices, the current value set in the factory settings is indicated (usually, this is the maximum indicator).

For a voltage relay (see “Device”), the rated current is the maximum current allowed for the device and the network segment protected by it for an unlimited time, in fact, the maximum current in normal operation. Exceeding this current is allowed, but not for long (up to several minutes) and not much, not higher than the maximum current (see below). And devices with the functions of a current relay or a power relay can work as follows: if the actual current is between the rated and maximum, the relay goes into the “delayed off” mode, and turns off the power after a certain period of time (for example, 10 minutes). This avoids both overload from long-term operation at high currents, and unnecessary power outages at large, but short-term permissible loads.

Maximum current

Maximum switching current allowed for the control relay. This is the maximum current that the device can safely pass through itself. And for models with current relay functions (see "Device"), this is also the default threshold of instantaneous operation — the current at which the relay instantly turns off the power to the load. In many models, you can set a lower threshold, but not a higher one.

Functions

Display. As a rule, control relays are equipped with simple segment LCD displays that can display numbers and some special characters. This screen performs two main functions. Firstly, during operation it displays key network parameters - voltage, power and/or power, as well as notifications of problems; Some models provide several separate displays, each with its own parameter. Secondly, the screen is used when changing device settings.

Operation indicator. A pointer indicating the operation of a device, and often a specific mode of operation. Note that in this case we are talking about the simplest indicators - for example, in the form of an LED, which lights up green in normal mode and lights up red after the protection is triggered. The display is not considered an operation indicator, although it can perform such a function.

Thermal protection. A safety system that turns off the device when it reaches a critical temperature. Some models also provide a shutdown when the permissible heating rate is exceeded. This function serves as additional insurance in case of malfunctions in the relay itself (for example, if the settings are lost and the device does not respond to overload), and in case of fire (in case of fire, the equipment must be de-energized).

Memory of emergency operations. The function...of saving data on the state of the network during emergencies. Allows you to assess the situation of what happened after resuming work.
DigiTOP VP-3F63A often compared