USA
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Hot Water Storage Tanks

Comparison Drazice NAD 1000 v5 1000 L vs Drazice NAD 1000 v2 1000 L

Add to comparison
Drazice NAD 1000 v5 1000 L
Drazice NAD 1000 v2 1000 L
Drazice NAD 1000 v5 1000 LDrazice NAD 1000 v2 1000 L
from $622.80 up to $718.48
Outdated Product
from $385.20 up to $456.73
Outdated Product
TOP sellers
Main
V5 - tanks without internal tank with a flange for mounting a TPK heating element and with two 1.5 m² heat exchangers.
V2 - tanks without an internal tank with the possibility of placing nozzles G 6/4".
Tank volume1000 L1000 L
Type of instalationverticalvertical
Specs
Max. tank temperature90 °C90 °C
Max. temperature in heat exchanger110 °C
Max. tank pressure3 bar3 bar
Max. heat exchanger pressure10 bar
Number of heat exchangers2no heat exchanger
Heat exchanger materialcarbon steel
Storage tank materialcarbon steelcarbon steel
General specs
Dimensions850х2053 mm
Weight123 kg
Country of originCzechiaCzechia
Added to E-Catalogfebruary 2016february 2016

Max. temperature in heat exchanger

The maximum temperature allowed for the heat exchanger(s) used in the tank.

For details on the heat exchangers, see "Number of heat exchangers". And the temperature of the heating medium supplied to them should not exceed the maximum allowable value. Otherwise, the device may fail at any time.

Max. heat exchanger pressure

The highest pressure allowed for the heat exchanger(s) used in the tank.

For details on the heat exchangers themselves, see "Number of heat exchangers". And the pressure should not exceed the maximum allowable value. Otherwise, the circuit may fail or be damaged at any time.

Number of heat exchangers

The number of heat exchangers provided in the design of the storage tank.

The simplest version of storage tanks are tanks without heat exchangers. They are designed for traditional use in the heating system — to remove excess heat, equalize the temperature characteristics and provide the system with heat in the event of a malfunction in the heater.

Heat exchangers installed in the storage tank can perform two main functions: removing heat from the tank or providing additional heating. One of the most popular options is to work as a water heater for a hot water supply system (in this case, one heat exchanger is enough). As an opposite example (additional heating), a heat exchanger connected to a solar collector can be given. There are storage tanks that have several heat exchangers ( 2 and 3 heat exchangers) and allow several additional applications at once. Anyway, the specific specialization of heat exchangers for each model should be specified separately.

Heat exchanger material

The material from which the heat exchanger installed in the tank is made. For more information on this equipment, see "Number of heat exchangers", and the materials can be:

Carbon steel. Steel with a high carbon content has good strength and, at the same time, is inexpensive. On the other hand, it is more sensitive to corrosion than stainless steel, so the service life of such heat exchangers is shorter.

Stainless steel. As the name suggests, this type of steel is highly resistant to corrosion. Stainless steel heat exchangers are the most reliable and durable. On the other hand, they are noticeably more expensive than similar carbon steel structures.
Drazice NAD 1000 v5 often compared
Drazice NAD 1000 v2 often compared