Comparison Cooper&Hunter CH-HP16UMNM 15 kW vs Cooper&Hunter CH-HP40MFNM 40 kW

Add to comparison
Cooper&Hunter CH-HP16UMNM 15 kW
Cooper&Hunter CH-HP40MFNM 40 kW
Cooper&Hunter CH-HP16UMNM 15 kWCooper&Hunter CH-HP40MFNM 40 kW
Outdated ProductOutdated Product
TOP sellers
Heat sourceair-waterair-water
Suitable forheating and DHWheating and DHW
In box
In box
outdoor unit (monoblock)
outdoor unit (monoblock)
Specs
Operating modeheating and coolingheating only
Max. heat output15.7 kW40 kW
Max. cooling output11.5 kW
Power consumption (heating)
4 kW /heating; 3.47 kW - cooling/
10 kW
EER2.9
Power source400 V400 V
Minimum operating temperature-30 °C-26 °C
Max. water temperature60 °C70 °C
Compressor
inverter
non-inverter
Energy efficiency
t°C outside77
Supply t°C35 °C35 °C
COP4.534
More specs
RefrigerantR410AR410A
Noise level60 dB67 dB
Country of brand originUSAUSA
Outdoor unit dimensions1280x980x390 mm930x1605x800 mm
Outdoor unit weight143 kg264 kg
Added to E-Catalogseptember 2018may 2018

Operating mode

Heating and cooling. Heat pumps that work on pumping heat in two directions. The main heating function is usually used for the water circuit of floor heating or radiator heating, and for cooling, such devices can replace fan coil units. It is worth noting that models with this mode can be used, for example, only for heating. For example, if the cooling system already exists, which will simplify the installation of communications in general.

Heating only. There are heat pumps that operate only in heating mode, which is important if the room already has an air conditioning system and cooling is not required.

Max. heat output

The maximum heat output generated by a heat pump is the amount of heat it can transfer from the outdoors into the heating system and/or domestic hot water.

The heat output is the most important spec of a heat pump. It directly determines its efficiency and ability to provide the required amount of heat. Note that this spec is shown for optimal operating conditions. Such conditions are rare, so the actual output heat is usually noticeably lower than the maximum; this must be taken into account when choosing. There are special formulas for calculating the optimal value of the maximum heat output, depending on the specific condition.

Max. cooling output

Maximum cooling output delivered by the pump.

The pump operates in the cooling mode removing excess heat from the room to the environment — it plays the role of an air conditioner. The required cooling capacity depends on the area of the building, the specs of its thermal insulation and some other factors; methods of its calculation can be found in special sources. Also note here that conventional heating equipment (radiators, underfloor heating) is not suitable for cooling, for this it is necessary to use special equipment (for example, fan coil units).

Power consumption (heating)

Electric power consumed by the heat pump when operating only for heat transfer, without the use of an additional heating element (if any, see below). The ratio of thermal power to power input determines the thermal coefficient COP (see below) and, accordingly, the overall efficiency of the unit. It also affects overall power consumption (and therefore electricity bills), as well as some power and connection requirements — for example, models powered by 230 V and with a power of more than 5 kW cannot work from an outlet and require a special connection to the mains.

EER

EER is the ratio of the heat pump's output cooling energy to the input electrical energy.

The higher this parameter, the more economical the device is and the higher its energy efficiency class when cooling. Each class has clear requirements for EER.

Minimum operating temperature

The lowest ambient temperature (air or ground, see Heat source) at which a heat pump can safely and reasonably efficiently perform its functions. Efficiency at minimum temperature, of course, is noticeably reduced, but the device can still be used as a heat source.

The data on the minimum operating T allows you to evaluate the suitability of the pump for the cold season.

Max. water temperature

The highest temperature to which the pump can heat the coolant. It is worth noting that such indicators can be achieved at a fairly high temperature of air or ground. And since heat pumps are used during the cold season, the actual maximum temperature, usually, is less than theoretically achievable. Nevertheless, this parameter makes it possible to evaluate the capabilities of the unit or its suitability for certain tasks.

Compressor

The compressor is the main element, the "heart" of the unit: it circulates the coolant through the heat pump circuits and transfers heat from outdoors to the room. Knowing the name of the compressor, you can find detailed information about it and find out some features of the heat pump as a whole. Note that the name is usually indicated if the device uses a high-end compressor, often an inverter one.

— Inverter. The presence of a compressor with inverter power control in the heat pump. Models without an inverter have only two modes of operation — either on or off; and the set intensity of heating/cooling is provided by turning the compressor on and off for certain periods. In turn, the principle of inverter control is to smoothly change the compressor power, which avoids constant switching on and off. It provides many advantages: minimal wear, no power surges and unnecessary load on the electrical mains, as well as a comfortable (low and stable) noise level.

COP

The COP (coefficient of performance) is a key characteristic that describes the overall efficiency of a heat pump. It represents the ratio between the thermal power and power consumption of the unit (see above) – in other words, how many kilowatts of thermal energy the pump produces per 1 kW of electricity consumed. In modern heat pumps, this figure can exceed 5.

However, note that the actual COP value may vary depending on the outside temperature and the supply temperature. The higher the difference between these temperatures, the more resources are needed to “pump” thermal energy and the lower the COP will be. Therefore, in the specifications it is customary to indicate the COP value for specific temperatures (and in many models – two values, for different options) – this allows you to evaluate the actual capabilities of the unit.