Add to comparison
B.Well MED-121
Microlife NEB 10
B.Well MED-121Microlife NEB 10
Outdated ProductOutdated Product
TOP sellers
Typecompressorcompressor
Purposestationarystationary
Specs
Medicine container5 ml12 ml
Compressor power12 W
Max air flow2 L/min15 L/min
Nebulization rate0.3 ml/min0.68 ml/min
Particle size
1.8 – 4 µm /aPI system, 4.6 — 10 µm Malvern system/
Medium particle size (MMAD)3 µm
Particle size changing
 /3 options/
Noise level46 dB53 dB
Nozzles
adult mask
children's mask
nozzle for mouth
adult mask
children's mask
nozzle for mouth
General
Case included
Power sourcemainsmains
Dimensions102x140x61 mm255х120х180 mm
Weight303 g2000 g
Added to E-Catalogoctober 2017may 2014

Medicine container

The nebuliser's built-in medicine reservoir volume is a crucial consideration. It's important to align this parameter with medical guidelines for the prescribed treatment. A too-small capacity may require frequent refilling, disrupting the treatment process.

Also, knowing the volume of the reservoir and the nebulization rate (see below), it is possible to estimate the operating time of the nebuliser on a single refill.

Compressor power

The power consumed by the compressor of the nebuliser during operation; in this case, it means not only the corresponding element of compressor models (see "Type"), but also the nebulizer in ultrasonic devices.

The performance and power consumption of the nebuliser depend on this parameter. The more powerful the compressor, the higher the possible air flow rate and, accordingly, nebulization. At the same time, powerful devices consume more power (which is especially important when powered offline, see below) and can generate quite a lot of noise.

Max air flow

The maximum air output of a compressor nebuliser during operation is a key factor to consider. It's important to note that actual performance during normal operation is often lower. Different applications have recommended air flow intensities, and knowing this parameter helps assess how well the inhaler aligns with specific recommendations.

Nebulization rate

The nebuliser's nebulization capacity per minute.

The ideal nebulization rate can differ based on factors such as the patient's health condition, the type of disease, and the composition of the inhaled medication, as outlined in medical guidelines. This rate is crucial in assessing the inhaler's effectiveness for specific situations and also influences how long the device operates on a single medication refill.

Some models have a nebulization speed control — in such cases, the maximum value is usually indicated in the characteristics.

Particle size

The aerosol generated by a nebuliser contains droplets of varying sizes. Smaller droplets have an easier time reaching the narrow passages of the bronchi, delivering the medicinal substance deeper into the respiratory system. For optimal therapeutic effects, it is recommended that droplet sizes do not surpass 5 microns. It's worth noting that during the atomization process, particles may vary in size, and their values are often expressed as a range.

Medium particle size (MMAD)

Since not all particles have the same size, this paragraph indicates exactly the average, most common particle size when splitting in this inhaler. Accordingly, lower values allow easier and deeper penetration into the bronchi.

Particle size changing

Possibility to change the size of the particles created during the nebulization of the medicinal product. See above for size value. Here we note that high penetrating power is not always required: for some diseases (for example, inflammation in the larynx or trachea), it is not necessary to deliver the medicine deep into the bronchi. Accordingly, by changing the particle size, it is possible to control the delivery distance.

Noise level

The nebuliser's maximum noise level during normal operation is a crucial factor for user comfort, especially in situations where loud sounds are undesirable, such as when treating children or during nighttime use. It's important to note that the relationship between decibel levels and actual perceived noise is not linear. For instance, a 3 dB increase corresponds to a doubling of noise, and a 20 dB increase equals a 100 — fold increase in noise. Comparative tables are often used to assess the actual loudness of inhalers, and here are some relevant values for modern devices:

30 dB — comparable to a whisper, the maximum permissible noise level in residential premises at night according to sanitary standards;
35 dB — talking in an undertone;
40 dB — normal speech at a distance of about 10 m;
45 dB — conversation in a normal voice;
50 dB — a conversation is slightly louder than usual, it is considered the maximum noise level that does not cause noticeable inconvenience;
55 dB — car engine;
60 dB — TV at medium volume;
65 dB — loud conversations at a distance of up to 1 m.

Case included

Availability in a set of delivery of an nebuliser of a case for storage and carrying. The cover provides a certain degree of protection against adverse effects — scratches, bumps, temperature changes, etc. Most often, it can also accommodate additional accessories, primarily nozzles — this reduces the risk of losing any accessory, and, in general, simplifies storage and transportation. This possibility is especially important for pocket models (refer to "Purpose"), the dimensions of which do not allow a special compartment to be provided in the case (see above).

Note that this category also includes models in which the cover is intended only for accessories, and not for the nebuliser itself.