Add to comparison
Blauberg VENTO Expert A50-1 S Pro
Blauberg VENTO Expert A50-1 Pro
Blauberg VENTO Expert A50-1 S ProBlauberg VENTO Expert A50-1 Pro
Outdated Product
from $320.76
Outdated Product
TOP sellers
Main
Built-in humidity sensor.
System typedecentralizeddecentralized
Ventilation typerecuperatorrecuperator
Mountingwallwall
Mounting diameter160 mm160 mm
Specs
Air filtersG3G3
Minimum air flow (ventilation)15 m³/h15 m³/h
Maximum air flow (ventilation)50 m³/h50 m³/h
Minimum air flow (recuperation)8 m³/h8 m³/h
Maximum air flow (recuperation)25 m³/h25 m³/h
Number of fan speeds33
Minimum noise level20 dB20 dB
Maximum noise level30 dB30 dB
Type of heat exchangerenthalpyenthalpy
Heat exchanger materialceramicsceramics
Heat exchanger efficiency97 %97 %
Minimum operating temperature-30 °C-30 °C
General specs
Remote control
EC fan
Power consumption in ventilation mode5 W5 W
Mains voltage230 V230 V
Minimum wall thickness150 mm240 mm
Maximum wall thickness500 mm500 mm
Decorative panel thickness64 mm
Country of originGermanyGermany
Dimensions
235х285х68 mm /indoor unit/
Added to E-Catalogjuly 2018september 2016

EC fan

The presence of an EC fan(fans) in the design of the air handling unit.

This term refers to fans with synchronous brushless motors, also known as EC motors. Such motors are more advanced than traditional asynchronous ones: in particular, they provide very uniform rotation, allow precise control of speed, have high efficiency, and generate almost no heat (which is extremely important in the presence of a cooler, see "Features"), and also efficiently operate over a wide temperature range. In addition, the noise level of such motors is noticeably lower, and the service life is longer. The main disadvantage of EC fans is the traditionally high price.

Minimum wall thickness

The minimum wall thickness on which the air ventilation unit can be hung with the possibility of wall mounting.

This parameter is indicated for models mounted directly into a hole in the wall — see "Mounting" for details. The installation length (the length of the pipe between the trims) can usually be adjusted to suit specific wall thicknesses. However, if this thickness is too small, then even an extremely shortened pipe will stick out of it, preventing the entire structure from being securely fixed. This is the reason for this limitation. Theoretically, the situation can be corrected — for example, by building up a wall at the installation site — however, in fact, such options are unlikely to be considered seriously. Nevertheless, in most models, this limitation does not exceed 300 mm, and it is very rarely necessary to install ventilation units on thinner walls.