USA
Catalog   /   Climate, Heating, Water Heating   /   Water Supply & Pumps   /   Water Pumps with Engine

Comparison Hyundai HYH52-80 vs Hyundai HYH50

Add to comparison
Hyundai HYH52-80
Hyundai HYH50
Hyundai HYH52-80Hyundai HYH50
Outdated Product
from $327.24 up to $363.76
Outdated Product
TOP sellers
Suitable forclean waterclean water
Specs
Maximum performance
16000 L/h /maximum/
30000 L/h /maximum/
Maximum head
80 m /maximum/
70 m /maximum/
Pump typecentrifugalcentrifugal
Suction typeself-primingself-priming
Suction height7 m8 m
Maximum particle size8 mm
Suction systemsingle-stagesingle-stage
Outlet size
2" /50 mm/
2 1/2" /50/38 mm/
Inlet hole size
2" /50 mm/
2" /50 mm/
Engine
Maximum power5150 W5150 W
Power sourcepetrolpetrol
 
212 cm³, 7 hp, 4-stroke, single-cylinder /manual starter, air-cooled/
210 cm³, 7 hp, 4-stroke, single-cylinder /manual starter, air-cooled/
Fuel tank volume3.6 L3.6 L
General specs
Country of originKoreaKorea
Dimensions530х425х430 mm530х425х430 mm
Weight27 kg27 kg
Added to E-Catalogmay 2018october 2014

Maximum performance

The maximum volume of water that the device can pump in a certain amount of time. It is one of the key specs of any pump because characterizes the volume of water with which the device can work. At the same time, it does not always make sense to pursue maximum performance — after all, it significantly affects the dimensions and weight of the unit.

Some formulas allow you to derive optimal performance values for different situations. So, if the pump is designed to supply water to water intake points, its minimum required performance should not be lower than the highest total flow rate; if desired, a margin of 20-30% can be added to this value. And for sewer models (see "Suitable for"), everything will depend on the volume of wastewater. More detailed recommendations for choosing a pump depending on performance can be found in special sources.

Maximum head

The maximum head generated by the pump. This parameter is most often indicated in meters, by the height of the water column that the unit can create — in other words, by the height to which it can supply water. You can estimate the pressure created by the pump using a simple formula: every 10 m of head corresponds to a pressure of 1 bar.

It is worth choosing a pump according to this parameter, taking into account the height to which it should supply water, as well as adjusting for losses and the need for pressure in the water supply. To do this, it is necessary to determine the difference in height between the water level and the highest point of water intake, add another 10 to 30 m to this figure (depending on the pressure that needs to be obtained in the water supply), and multiply the result by 1.1 — this will be the minimum pressure required.

Suction height

The largest difference between the height of the pump and the height of the water level at which the pump can provide normal suction. Without special devices, the maximum value of this parameter is 7-8 m — this is due to the physics of the process. However, when using an ejector (see below), the suction height can be increased several times.

Maximum particle size

The largest particle size that the pump can handle without problems. This size is the main indicator that determines the purpose of the device (see above); and in general, the larger it is, the more reliable the device, the lower the risk of damage if a foreign object enters the suction line. If the risk of the appearance of too large mechanical impurities is still high, additional protection can be provided with filters or grids at the inlet. However, such a measure should be considered only as a last resort, because from constant exposure to solid particles, the grids become clogged and deformed, which can lead to both clogging of the line and filter breakthrough.

Outlet size

The thread size for connecting a hose or pipe to the pump outlet. If there is a branch pipe with an external thread in the design, the size is indicated for it; if not, for the internal thread of the inlet.

Anyway, the dimensions of the pump outlet and the mounts on the hose/pipeline connected to it must match — otherwise, you will have to look for adapters. This size is specified in inches and fractions of an inch.

This parameter is relevant primarily for surface models.

Хар-ки двигателя

 
Hyundai HYH52-80 often compared