Dark mode
USA
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Radiators

Comparison Kermi Therm-X2 Profil-V 22 500x800 vs Buderus Logatrend VK-Profil 22 500x800

Add to comparison
Kermi Therm-X2 Profil-V 22 (500x800)
Buderus Logatrend VK-Profil 22 (500x800)
Kermi Therm-X2 Profil-V 22 500x800Buderus Logatrend VK-Profil 22 500x800
from $81.28 up to $148.31
Outdated Product
Expecting restock
TOP sellers
Radiator typepanelpanel
Country of originGermanyGermany
Manufacturer's warranty10 years5 years
Technical specs
Materialsteelsteel
Panel type2222
Operating pressure10 bar8.7 bar
Max. pressure13 bar13 bar
Heat transfer medium volume4.16 L5.04 L
Heat tranfer medium max. temperature110 °C120 °C
Mountingwallwall
Connectionbottom sidebottom side
Pipe centre distance50 mm450 mm
Connection size3/4"3/4"
Heat output1544 W1808 W
Radiator height500 mm500 mm
Radiator width800 mm800 mm
Radiator depth100 mm100 mm
Weight23.04 kg
Added to E-Catalogmarch 2015february 2015

Manufacturer's warranty

The manufacturer's warranty period for this model.

Usually, the terms of the warranty provide free rectification, replacement and/or compensation if the radiator fails during the stated period due to manufacturing defects. The greater the guarantee, the higher the quality of the product and the higher its cost (the latter, however, is usually compensated by high reliability). In modern radiators, the warranty period can be up to 10 years.

Note that the end of the warranty does not mean the product will immediately fail: with proper workmanship, the total service life exceeds the warranty significantly.

Operating pressure

Radiator operating pressure.

This term usually means the highest pressure of the heating medium that the radiator can sustain without consequences for an indefinitely long time. Higher rates are also allowed for a short time (see "Maximum pressure"). However, the standard operating pressure in the heating system should not exceed the specs of the radiator; otherwise, the product is likely to be damaged. In general, it is believed that this indicator should be at least 2 bar higher than the actual working pressure in the system — this will give an additional margin of safety in case of emergencies.

Heat transfer medium volume

The volume of water or other heating medium required to fill the radiator.

This information is relevant mainly when building an autonomous heating system: it is useful when calculating the total volume of heating medium in the system and related parameters. If the radiator is purchased for use in centralized heating, you can not pay much attention to its internal volume.

Heat tranfer medium max. temperature

The maximum heating medium temperature allowed for a radiator is the highest temperature the product can withstand without consequences for a sufficiently long time.

The maximum temperature for heating systems (both centralized and autonomous) is +95 °С as standard. Thus, most radiators have an upper temperature limit of +110 ... 120 °C — this allows you to withstand such conditions confidently.

Pipe centre distance

The distance between the axes of the inlet and outlet manifolds of the radiator or its separate section.

The dimensions of the product and the possibility of installing the heater in specific conditions, taking into account the peculiarities of the pipe connection, directly depend on this parameter. The parameter is indicated mainly for models of traditional design - with two horizontal pipes at the top and bottom, between which vertical channels of the heat transfer are laid. The centre distance determines at least the overall height of the product, and in radiators with sideward connection (see the corresponding paragraph), it also determines the features of the organization of this connection.

As for specific values, the most common models in our time are 250 mm, 350 mm, 450 mm, 550 mm and 850 mm. Solutions for 150 mm, 400 mm, 500 mm and 700 mm are noticeably less common.

Heat output

The rated thermal output of the radiator is the amount of heat given off to the air in normal operation.

When choosing this parameter note that the heat output will depend on the temperature difference at the inlet and outlet to the radiator, as well as on the ambient temperature. The greater the temperature difference and the colder it is around, the more intense the heating will be. Therefore, in the specs, it is customary to indicate heat transfer for certain standard conditions. In particular, the designation according to the European standard EN-442 is very popular, which assumes heating medium temperatures of +75 °С and +65 °С at the inlet and outlet, respectively, as well as an air temperature of +20 °С. Real conditions and the actual heat output of the radiator may differ; therefore, when choosing, it is best to choose a model with a certain margin and compensate for excess power with one or another regulator. As for the actual values, in the most modest models, the heat outputdoes not exceed 750 W, or even 500 W, and in the largest, this figure can reach 3.5 – 4 kW or more.

The choice for this parameter depends primarily on the size and specs of the heated space. The simplest calculation formula is as follows: at least 100 W of thermal power is required per 1 m2 of area. This formula is relevant for standard r...esidential/office premises with ceilings of 2.5 – 3 m, without problems with thermal insulation; for more specific conditions, there are more detailed calculation methods, that can be found in special sources.
Kermi Therm-X2 Profil-V 22 often compared