Comparison Bosch Tronic Heat 3000 9 8.91 kW
230 V
vs Bosch Tronic Heat 3500 9 8.91 kW
230 V

Add to comparison
Bosch Tronic Heat 3000 9 8.91 kW 230 V
Bosch Tronic Heat 3500 9 8.91 kW 230 V
Bosch Tronic Heat 3000 9 8.91 kW
230 V
Bosch Tronic Heat 3500 9 8.91 kW
230 V
from $520.14 up to $644.72
Outdated Product
from $622.56 up to $803.12
Outdated Product
TOP sellers
Main
Self-diagnosis function. Ability to work in 220/400 V networks. Support for connecting many additional accessories. High reliability.
Energy sourceelectricityelectricity
Installationwallwall
Typesingle-circuit (heating only)single-circuit (heating only)
Heating area71 m²71 m²
Technical specs
Heat output8.91 kW8.91 kW
Min. heat output3 kW3 kW
Power supply230 V230 V
Coolant max. T85 °С85 °С
Heating circuit max. pressure3 bar3 bar
Consumer specs
"Summer" mode
Circulation pump
Boiler specs
Efficiency99.7 %99.7 %
Combustion chamberno chamberno chamber
Expansion vessel capacity7 L
Connections
Central heating flow3/4"3/4"
Central heating return3/4"3/4"
Safety
Safety systems
water overheating
 
frost protection
water overheating
water circulation failure
frost protection
More specs
Dimensions (HxWxD)712x330x193 mm712x330x273 mm
Weight17.8 kg17 kg
Added to E-Catalogoctober 2016september 2016

Circulation pump

The presence in the boiler of circulation pump.

Such a pump ensures the movement of the coolant along the heating circuit, due to which the heat is evenly and efficiently distributed over the radiators. Similar devices are also available as separate devices; however, buying a boiler with a circulation pump eliminates the need to purchase additional equipment and simplifies the heating system. The disadvantages of such models include the complex design: if a separate pump fails, it is enough to replace only it, and the module built into the boiler may require complex and expensive repairs, and the heating system becomes unavailable.

Also note that it is theoretically possible to build a heating system without a pump, based on natural circulation; however, such systems have several disadvantages, so it is still preferable to use forced circulation.

Expansion vessel capacity

The capacity of the expansion tank supplied with the boiler.

The expansion tank is designed to drain excess water from the heating system when the total volume of liquid increases as a result of heating. It consists of two parts connected by a flexible membrane: in one, hermetically closed, there is air under pressure; in the other, excess water enters, compressing the membrane. In this way, a catastrophic increase in pressure in the heating circuit is avoided. The optimal volume of the expansion tank depends on several system parameters, primarily the volume and composition of the coolant; detailed recommendations for calculations can be found in special sources.

Safety systems

Gas pressure drop. This protection system ensures that the boiler is switched off in the event of a critical drop in gas pressure, insufficient for the normal functioning of the burner. In the event of such a fall, the valve that supplies gas to the burner is closed and blocked. After the restoration of gas pressure, it also remains closed; it is necessary to open it and resume the gas supply manually.

Water overheating. A temperature sensor automatically turns off the boiler when the temperature of the water in the system is critically exceeded.

Flame loss. Flame loss protection is based on a sensor that monitors the combustion of gas and automatically stops its supply. It prevents the room from filling with gas and the possible tragic consequences of this.

Draft control. In boilers with an open combustion chamber, to maintain normal conditions in the room where such a boiler is installed, constant removal of products of combustion into the atmosphere is necessary. The lack of a normal draft in the chimney can lead to the accumulation of combustion products in the room. The draft protection system prevents this by automatically turning off the boiler when it detects the release of combustion products outside the chimney.

Power outage. Most modern boilers h...ave an electronic control system; in addition, many structural elements (pumps, valves, fans, etc.) are also powered by electricity. Thus, a power outage during the operation of the boiler will inevitably lead to an abnormal mode of operation, which is fraught with breakdowns and even accidents. To prevent such cases, a power outage protection system is installed, which completely stops the operation of the boiler in the event of a power outage. When the power supply is restored, the boiler needs to be restarted manually.

Water circulation failure. This protection system controls the normal movement of the water through the heating circuit. Water circulation failure can lead to overheating of some elements of the boiler and damage to it. To avoid this, if the circulation is disturbed, the system turns off the pump and shuts off the gas supply to the burner.

Frost protection. A system that controls the temperature in the heating circuit. Freezing of the liquid in the circuit disrupts the normal operation of the heating, which may require heating of the pipes and lead to system damage. To avoid this, when the water temperature drops below 5 °C, the burner is ignited, the circulation pump is activated, and the circuit warms up to a temperature of about 35 °C — thus preventing the formation of ice in the pipes.
Bosch Tronic Heat 3500 9 often compared