Comparison ATON Atmo 8EM 8 kW vs ATON Atmo 8E 8 kW
Add to comparison | ![]() | ![]() |
|---|---|---|
| ATON Atmo 8EM 8 kW | ATON Atmo 8E 8 kW | |
from $197.60 up to $213.44 | from $188.64 up to $220.53 | |
| User reviews | ||
| TOP sellers | ||
| Energy source | gas | gas |
| Installation | floor | floor |
| Type | single-circuit (heating only) | single-circuit (heating only) |
| Heating area | 60 m² | 64 m² |
Technical specs | ||
| Heat output | 8 kW | 8 kW |
| Power supply | autonomous (no electricity) | autonomous (no electricity) |
| Coolant min. T | 50 °С | 50 °С |
| Coolant max. T | 90 °С | 90 °С |
| Heating circuit max. pressure | 1 bar | 1 bar |
Consumer specs | ||
| Circulation pump | ||
Boiler specs | ||
| Efficiency | 90 % | 90 % |
| Combustion chamber | open (atmospheric) | open (atmospheric) |
| Flue diameter | 110 mm | 110 mm |
| Inlet gas pressure | 12 mbar | 12 mbar |
| Max. gas consumption | 0.94 m³/h | 0.89 m³/h |
Connections | ||
| Gas supply | 1/2" | 1/2" |
| Central heating flow | 1 1/2" | 1 1/2" |
| Central heating return | 1 1/2" | 1 1/2" |
Safety | ||
| Safety systems | gas pressure drop water overheating flame loss draft control | gas pressure drop water overheating flame loss draft control |
More specs | ||
| Dimensions (HxWxD) | 760x325x385 mm | 746x264x610 mm |
| Weight | 36 kg | 39 kg |
| Added to E-Catalog | june 2016 | august 2012 |
Compare ATON Atmo 8EM and Atmo 8E
You may be interested in
My comparisons
ATON Atmo 8EM often compared
ATON Atmo 8E often compared
Glossary
Heating area
A very conditional parameter that slightly characterizes the purpose based on the size of the room. And depending on the height of the ceilings, layout, building design and equipment, actual values may differ significantly. However, this item represents the maximum recommended area of the room that the boiler can effectively heat. However, it is worth considering that different buildings have different thermal insulation properties and modern buildings are much “warmer” than 30-year-old and especially 50-year-old houses. Accordingly, this item is more of a reference nature and does not allow us to fully assess the actual heated area. There is a formula by which you can derive the maximum heating area, knowing the useful power of the boiler and the climatic conditions in which it will be used; For more information on this, see "Useful Power". In our case, the heating area is calculated using the formula “boiler power multiplied by 8”, which is approximately equivalent to use in houses that are several decades old.
Max. gas consumption
Maximum gas consumption in the boiler with the corresponding energy source (see above). Achieved when the gas heater is operating at full capacity; with reduced power and consumption, respectively, will be lower.
Note that boilers of the same power may differ in gas consumption due to the difference in efficiency. While the more fuel-efficient models tend to cost more, the price difference pays off in gas savings.
Note that boilers of the same power may differ in gas consumption due to the difference in efficiency. While the more fuel-efficient models tend to cost more, the price difference pays off in gas savings.