Comparison ATON Atmo 8EM 8 kW vs ATON Atmo 8E 8 kW

Add to comparison
ATON Atmo 8EM 8 kW
ATON Atmo 8E 8 kW
ATON Atmo 8EM 8 kWATON Atmo 8E 8 kW
from $197.60 up to $213.44
Outdated Product
from $188.64 up to $220.53
Outdated Product
TOP sellers
Energy sourcegasgas
Installationfloorfloor
Typesingle-circuit (heating only)single-circuit (heating only)
Heating area60 m²64 m²
Technical specs
Heat output8 kW8 kW
Power supplyautonomous (no electricity)autonomous (no electricity)
Coolant min. T50 °С50 °С
Coolant max. T90 °С90 °С
Heating circuit max. pressure1 bar1 bar
Consumer specs
Circulation pump
Boiler specs
Efficiency90 %90 %
Combustion chamberopen (atmospheric)open (atmospheric)
Flue diameter110 mm110 mm
Inlet gas pressure12 mbar12 mbar
Max. gas consumption0.94 m³/h0.89 m³/h
Connections
Gas supply1/2"1/2"
Central heating flow1 1/2"1 1/2"
Central heating return1 1/2"1 1/2"
Safety
Safety systems
gas pressure drop
water overheating
flame loss
draft control
gas pressure drop
water overheating
flame loss
draft control
More specs
Dimensions (HxWxD)760х325х385 mm746х264х610 mm
Weight36 kg39 kg
Added to E-Catalogjune 2016august 2012

Heating area

A very conditional parameter that slightly characterizes the purpose based on the size of the room. And depending on the height of the ceilings, layout, building design and equipment, actual values may differ significantly. However, this item represents the maximum recommended area of the room that the boiler can effectively heat. However, it is worth considering that different buildings have different thermal insulation properties and modern buildings are much “warmer” than 30-year-old and especially 50-year-old houses. Accordingly, this item is more of a reference nature and does not allow us to fully assess the actual heated area. There is a formula by which you can derive the maximum heating area, knowing the useful power of the boiler and the climatic conditions in which it will be used; For more information on this, see "Useful Power". In our case, the heating area is calculated using the formula “boiler power multiplied by 8”, which is approximately equivalent to use in houses that are several decades old.

Max. gas consumption

Maximum gas consumption in the boiler with the corresponding energy source (see above). Achieved when the gas heater is operating at full capacity; with reduced power and consumption, respectively, will be lower.

Note that boilers of the same power may differ in gas consumption due to the difference in efficiency. While the more fuel-efficient models tend to cost more, the price difference pays off in gas savings.