USA
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Boilers

Comparison ATON Compact 12.5E 12.5 kW vs ATON Compact 10EB 10 kW

Add to comparison
ATON Compact 12.5E 12.5 kW
ATON Compact 10EB 10 kW
ATON Compact 12.5E 12.5 kWATON Compact 10EB 10 kW
from $233.68 up to $316.16
Outdated Product
from $247.40 up to $295.22
Outdated Product
TOP sellers
Energy sourcegasgas
Installationparapetparapet
Typesingle-circuit (heating only)dual-circuit (heating and DHW)
Heating area94 m²75 m²
Technical specs
Heat output12.5 kW10 kW
Power supplyautonomous (no electricity)autonomous (no electricity)
Coolant max. T90 °С90 °С
Heating circuit max. pressure1.5 bar1.5 bar
DHW circuit max. pressure6 bar
Consumer specs
Circulation pump
Boiler specs
Efficiency90 %90 %
Combustion chamberclosed (turbocharged)closed (turbocharged)
Flue diameter60/100 mm60/100 mm
Inlet gas pressure13 mbar13 mbar
Max. gas consumption1.5 m³/h1.2 m³/h
Connections
Mains water intake1/2"
DHW flow1/2"
Gas supply1/2"1/2"
Central heating flow1 1/2"1 1/2"
Central heating return1 1/2"1 1/2"
Safety
Safety systems
gas pressure drop
water overheating
flame loss
gas pressure drop
water overheating
flame loss
More specs
Dimensions (HxWxD)700х245х690 mm700х270х580 mm
Weight50 kg43 kg
Added to E-Catalogmarch 2012march 2012

Type

Depending on the set of functions, boilers are divided into single-circuit and dual-circuit.

- Single-circuit boilers are equipped with one heat exchanger, in which the heat from fuel combustion is transferred to the heat medium of the heating system. The only function of such boilers is space heating. It is technically possible to use single-circuit boilers to provide hot water, but this requires an additional tank (the so-called indirect water heater).

- In dual-circuit boilers, the primary heat exchanger is supplemented by a secondary one. Due to this, such a boiler, in addition to heating the room, also provides a hot water supply. In this case, both running water and water accumulated in a special tank(see Built-in water heater tank) can be used.

Heating area

A very conditional parameter that slightly characterizes the purpose based on the size of the room. And depending on the height of the ceilings, layout, building design and equipment, actual values may differ significantly. However, this item represents the maximum recommended area of the room that the boiler can effectively heat. However, it is worth considering that different buildings have different thermal insulation properties and modern buildings are much “warmer” than 30-year-old and especially 50-year-old houses. Accordingly, this item is more of a reference nature and does not allow us to fully assess the actual heated area. There is a formula by which you can derive the maximum heating area, knowing the useful power of the boiler and the climatic conditions in which it will be used; For more information on this, see "Useful Power". In our case, the heating area is calculated using the formula “boiler power multiplied by 8”, which is approximately equivalent to use in houses that are several decades old.

Heat output

It is the maximum useful power of the boiler.

The ability of the device to heat a room of a particular area directly depends on this parameter; by power, you can approximately determine the heating area, if this parameter is not indicated in the specs. The most general rule says that for a dwelling with a ceiling height of 2.5 – 3 m, at least 100 W of heat power is needed to heat 1 m2 of area. There are also more detailed calculation methods that take into account specific factors: the climatic zone, heat gain from the outside, design features of the heating system, etc.; they are described in detail in special sources. Also note that in dual-circuit boilers (see "Type"), part of the heat generated is used to heat water for the hot water supply; this must be taken into account when evaluating the output power.

It is believed that boilers with a power of more than 30 kW must be installed in separate rooms (boiler rooms).

DHW circuit max. pressure

The maximum pressure in the hot water circuit (DHW) at which it can operate for a long time without failures and damage. See "Heating circuit maximum pressure".

Max. gas consumption

Maximum gas consumption in the boiler with the corresponding energy source (see above). Achieved when the gas heater is operating at full capacity; with reduced power and consumption, respectively, will be lower.

Note that boilers of the same power may differ in gas consumption due to the difference in efficiency. While the more fuel-efficient models tend to cost more, the price difference pays off in gas savings.

Mains water intake

The diameter of the pipe for connecting the pipe through which cold water is supplied to the boiler for heating and use in the hot water supply system.

Diameters are indicated in inches. It is allowed to connect a pipe of a different diameter through an adapter, but the best option is still a match in size. There are connection options 1/2", 3/4", 1" and 1 1/2".

DHW flow

The diameter of the pipe for connecting the pipe through which hot water leaves the boiler for the DHW system.

Diameters are indicated in inches. It is allowed to connect a pipe of a different diameter through an adapter, but the best option is still a match in size.
ATON Compact 12.5E often compared