USA
Catalog   /   Climate, Heating, Water Heating   /   Heating & Cooling   /   Air Conditioners

Comparison Daikin Sensira FTXB20C/RXB20C 20 m² vs Toshiba RAS-07EKV-EE/07EAV-EE 20 m²

Add to comparison
Daikin Sensira FTXB20C/RXB20C 20 m²
Toshiba RAS-07EKV-EE/07EAV-EE 20 m²
Daikin Sensira FTXB20C/RXB20C 20 m²Toshiba RAS-07EKV-EE/07EAV-EE 20 m²
from $572.00 up to $699.60
Outdated Product
from $543.20 up to $624.24
Outdated Product
TOP sellers
Typesplit systemsplit system
Installationwallwall
Nominal capacity BTU70007000
Recommended room area20 m²20 m²
In box
indoor unit
outdoor unit
indoor unit
outdoor unit
Features
Modes and programs
cooling, heating, dehumidification, ventilation
automode
night mode
 
cooling, heating, dehumidification, ventilation
automode
 
self-cleaning
Functions
inverter compressor
timer
auto restart
self-diagnosis
inverter compressor
timer
auto restart
self-diagnosis
Performance
Power consumption (cooling/heating)510/600 W550/590 W
Cooling capacity2000 W2000 W
Heating capacity2500 W2500 W
Air flow504 m³/h
516 m³/h /heating, 468 m3/h — cooling/
Noise level (max/min)39/21 dB38/26 dB
Refrigerant typeR410АR410А
Efficiency
Cooling EER3.943.64
Heating COP4.194.24
Energy efficiency EER (cooling)AA
Energy efficiency COP (heating)AA
Min. T for cooling mode-10 °C10 °C
Maximum T for cooling mode46 °C
Min. T for heating mode-15 °C-15 °C
General specs
Displayhidden
Maximum height difference between units8 m
Maximum pipe length10 m
Indoor unit dimensions (WxHxD)
770x283x216 mm /weight — 8 kg/
790x275x205 mm /weight - 9 kg/
Dimensions of window/outdoor unit (WxHxD)
658x550x275 mm /weight — 27 kg/
660x530x240 mm /weight — 27 kg/
Color
Added to E-Catalogapril 2015march 2014

Modes and programs

Cooling and ventilation modes are in each model by definition. But air conditioners with humidification are relatively rare. For them, the opposite format is mandatory — dehumidification and heating.

- Cooling. The mode of lowering the air temperature in the room is the main function of any air conditioner. Note that conventional air conditioners, when cooled, also remove moisture from the air. However, due to a decrease in temperature, the relative humidity in this mode changes slightly (or does not change at all).

- Ventilation. The mode in which the air conditioner provides only air circulation throughout the room, without changing its temperature and humidity. Such a function can be useful, for example, for air mixing and temperature equalization; in addition, when passing through the air conditioner, the air is filtered, which is useful, for example, for cleaning from dust and smoke, or for ensuring hygiene in a room where a sick person is. Let us emphasize that ventilation must be distinguished from the fresh air intake(see "Functions"). The ability to add air from outside is rare and only in expensive models of air conditioners.

- Dehumidification. Mode for removing excess moisture from the air. This function works by condensing water vapour on the cold heat exchanger of the air conditioner; the collected mo...isture is usually removed to the outside through a drainage tube or accumulates in a special reservoir. Note that condensation also occurs in the cooling mode (see above); the dehumidification mode differs from it in that the temperature of the air passed through the air conditioner changes very slightly — usually by no more than 1 °C — but the humidity drops very noticeably.

— Heating. The mode of increasing the air temperature in the room. It should be borne in mind that most air conditioners with this function are not designed to be used as full-fledged heating systems - their task is to "help" such systems, as well as heating in the off-season, when the main heating does not work. In addition, the permissible outside temperature (see “Minimum t for heating mode”) can be different: for example, not every unit with a heating mode can work in cold weather. On the other hand, there are exceptions - powerful cold-resistant models, approaching the characteristics of heat pumps and withstanding temperatures of -25 ° C and even lower.

- Humidification. A need to increase air humidity often arises in winter. When the air is heated by heating devices, its relative humidity decreases (and the overall comfort in the room is associated precisely with relative humidity). In addition, in rooms where there are small children, it is recommended to specially humidify the air. The humidifying mode in air conditioners is rare and only in premium models. And for the operation of the humidifier, a supply of water is required, which must be monitored and periodically replenished.

Fresh air intake. Ability to mix fresh air from outside with the air passed through the conditioner. Thus, models with this function not only change the temperature and humidity of the air but also additionally refresh it. On the other hand, mixing significantly complicates both the design of the air conditioner itself and its installation. Therefore, this function is rare, and mainly in models of the middle level and above.

Automode. A function that relieves the user of the need to manually control the parameters of the air conditioner. It is enough just to set the desired microclimate in the room. After that, the unit will independently monitor the current conditions and select the desired operating mode. Most often, this function provides temperature monitoring and automatic switching between cooling and heating but advanced models may provide more advanced features, such as humidity monitoring with automatic dehumidification or even humidification.

Night mode. A function that allows you to use the air conditioner as comfortably as possible at night. There are two main features of this mode. First, the fan speed is set to a minimum, which reduces noise and avoids strong air currents that can disturb sleepers. Secondly, the temperature change occurs very slowly and smoothly — by a couple of degrees within two to three hours; this is considered optimal for sleep. Additionally, in the night mode, a timer can be provided that turns off the air conditioner after 7-8 hours.

Emergency heating. A function found in air conditioners with heating (see "Operating modes"); is intended mainly for summer cottages and other similar places that can be left unattended for a long time during the cold season. When using standby heating, the air conditioner maintains a low positive temperature in the room (about +8..10 °С). It is enough to avoid freezing of walls and damage to communications, and at the same time, energy consumption is low.

Self-cleaning. The mode of automatic cleaning of the internal parts of the air conditioner — usually due to intensive purging with air. It allows you to remove the accumulated dust inside and dry out excess moisture and also prevents the growth of harmful microorganisms. At the same time, self-cleaning does not eliminate the need for full manual cleaning or replacement of working elements in the air conditioner filters.

Power consumption (cooling/heating)

Power consumption of the air conditioner in cooling and heating mode; for models without a heating mode, only one number is given. This parameter should not be confused with the effective capacity of the air conditioner. Effective capacity is the amount of heat that the unit can "pump" into the environment or the room. This item also indicates the amount of electricity consumed by the device from the network.

In all air conditioners, the power consumption is several times lower than the effective capacity. It is due to the peculiarities of the operation of such units. At the same time, devices with the same efficiency may differ in power consumption. In such cases, the more economical models usually cost more, but with continued use, the difference can quickly pay off with less electricity consumption.

Also, two points related to electrical engineering depend on this nuance. Firstly, power consumption affects power requirements: models up to 3 – 3.5 kW can be connected to a regular outlet, while higher power consumption requires a three-phase connection (see below). Secondly, the power consumption is needed to calculate the load on the mains and the necessary parameters of additional equipment: stabilizers, emergency generators, uninterruptible power supplies, etc.

Air flow

The amount of air that an air conditioner can pass through itself in an hour.

This parameter depends on the power and the overall level of the device, but there is no strict dependence here: models with the same effective capacity may differ in air circulation speed. In such cases, it is worth proceeding from the fact that a higher speed contributes to uniform cooling/heating of the air and reduces the time required to create a given microclimate; on the other hand, higher-performing air conditioners use more energy, are larger and/or cost more.

Noise level (max/min)

The maximum and minimum level of noise produced by the air conditioner during operation; for split and multi split systems (see "Type"), by default, it is indicated for the indoor unit, and the data for the outdoor unit can be specified in the notes.

The noise level is indicated in decibels; this is a non-linear unit, so it is easiest to evaluate this parameter using comparative tables — they can be found in special sources. Here we note that, according to sanitary standards, the maximum level of constant noise for residential premises is 40 dB during the day and 30 dB at night; for offices, this figure is 50 dB, and in industrial premises higher volume levels may be allowed. So it is worth choosing an air conditioner according to this indicator, taking into account where and how it is planned to use it.

As for specific numbers, among the quietest modern air conditioners, there are models with a minimum performance of 23 – 24 dB, 22 – 21 dB, and sometimes even 20 dB or less. However, units at 31 – 31 dB and 33 – 34 dB are not uncommon; such loudness, usually, does not create discomfort in the daytime, but at night it is no longer desirable. However, in some cases, a louder air conditioner may be the best choice: noise reduction affects the cost, sometimes quite noticeably, and if the device...is not planned to be turned on at night, you can not overpay for additional noise reduction.

Cooling EER

Cooling factor EER provided by the air conditioner. It is calculated as the ratio of the useful operating power of the air conditioner in cooling mode to the electricity consumption. For example, a device that delivers 6 kW of operating power in cooling mode and consumes 2 kW will have an EER 6/2 = 3.

The higher this indicator, the more economical the air conditioner is and the higher its cooling energy efficiency class (see below). Each class has its clear requirements for EER.

It is worth noting that this indicator is considered not very reliable, and in the European Union another coefficient has been introduced that is closer to practice — SEER. See Energy efficiency SEER (cooling) for more details.

Heating COP

The heating coefficient COP provided by the air conditioner. It is calculated as the ratio of the heat output of the air conditioner in heating mode to the electricity consumption. For example, if a device consumes 2 kW and produces 5 kW of thermal power, then the COP will be 5/2 = 2.5.

The higher this indicator, the more economical the air conditioner is and the higher its energy efficiency class when heating (see below). Each class has its own clear COP requirements.

Note that COP values are usually higher than the values of another important coefficient — EER (see above). It is due to the technical features of the air conditioners.

It is also worth mentioning that since 2013, a more advanced and closer-to-practice coefficient, SCOP, has been put into use in Europe. See "Energy efficiency SCOP (heating)" for more details.

Min. T for cooling mode

The lowest outdoor air temperature at which the air conditioner can operate normally in cooling mode.

The need for air cooling arises not only in hot weather — for example, efficient heat dissipation is constantly needed in closed rooms with a lot of heat-generating equipment (such as server rooms). And the limitation on the minimum outdoor temperature is because a large temperature difference between the condenser (heater) of the outdoor unit and the environment can damage the circuits.

Note that in domestic air conditioners, this limit can be quite high — +20 °С and even higher (up to +25 °С); however, additional cooling is usually required for warmer weather, and such air temperatures are not so high as to cause significant discomfort. But in professional units, the minimum temperature for the cooling mode can be significantly below zero — up to -40 °C and even lower.

It is also worth mentioning that in the presence of a heating mode, the permissible temperature for it is noticeably lower than for the cooling mode. It is due to the difference between the formats of the air conditioner in these modes.

Maximum T for cooling mode

The highest outdoor air temperature at which normal operation of the air conditioner in normal cooling mode is possible.

It should be noted that for basic models of home climate equipment, the max outdoor air temperature for cooling is usually +43 °С. Advanced models of air conditioners remain operational at +50 °С and even at +55 °С (which almost reaches the absolute maximum air temperature on our planet).

Display

A small screen installed on the indoor unit of the air conditioner. Such a display usually has basic functionality and displays a limited set of characters - numbers, some letters, sometimes also individual graphic icons. However, even such a screen can display quite a variety of information: set temperature, operating mode, timer settings, filter status, error codes, etc. Thanks to this, control is more convenient and visual.

Hidden display. When switched off, the hidden info display blends in with the surface design of the indoor unit of the air conditioner and remains invisible. In active mode, the characters on the screen are visible through a certain place in the texture and all the necessary information is displayed on the display. On most models, the screen can be turned off using the remote control, and this feature can often be set to automatically hide after a certain period of inactivity, which will be useful at night.
Daikin Sensira FTXB20C/RXB20C often compared
Toshiba RAS-07EKV-EE/07EAV-EE often compared