USA
Catalog   /   Climate, Heating, Water Heating   /   Heating & Cooling   /   Humidifiers

Comparison Panasonic F-VXK90R vs Panasonic F-VXK70R

Add to comparison
Panasonic F-VXK90R
Panasonic F-VXK70R
Panasonic F-VXK90RPanasonic F-VXK70R
from $1,018.36 up to $1,112.36
Outdated Product
from $763.96 up to $865.16
Outdated Product
TOP sellers
Main
The motion sensor automatically regulates the operation of the device.
The motion sensor automatically regulates the operation of the device. Cleaner auto mode. Multilevel air purification. Hygrostat. Ionizer. Touchscreen. Automatic night mode. Timer. Child protection.
Type
humidifier
air washer
air purifier
humidifier
air washer
air purifier
Humidiationrated powerrated power
Room area (humidification)38 m²32 m²
Room area (purification)66 m²52 m²
Filters and functions
Filters
pre-filter
HEPA
Deodorant
pre-filter
HEPA
Deodorant
Functions
humidity control (hygrostat)
night mode
ionizer
auto mode
shutdown timer
child lock
display
humidity indicator
air quality indicator
humidity control (hygrostat)
night mode
ionizer
auto mode
shutdown timer
child lock
display
humidity indicator
air quality indicator
Specs
Controlstouch controlselectronic
Air flow522 m³/h402 m³/h
Operating time4 h
Water consumption830 mL/h700 mL/h
Water tank volume3.2 L
Min. noise level25 dB
Maximum noise level55 dB53 dB
Power consumption88 W58 W
Power sourcemainsmains
Dimensions (HxWxD)636x398x265 mm636x398x265 mm
Weight9.7 kg
Color
Added to E-Catalogjanuary 2017january 2017

Room area (humidification)

A very conditional parameter that slightly characterizes the purpose based on the size of the room. And depending on the height of the ceilings, layout, building design and equipment, actual values may differ significantly. However, this item represents the maximum recommended room area for which the device is designed. In fact, this paragraph indicates the maximum service area in air humidification mode: use on a smaller area is quite acceptable, but the device simply does not have enough performance for a larger space. We also note that the area is indicated based on a standard ceiling height of 2.5 - 3 m. With higher ceiling heights, the effective humidification space decreases; it can be recalculated using special formulas.

When choosing by area, it is worth taking a certain reserve, but it should not be too large - otherwise the device will turn out to be overly powerful, bulky and expensive.

Room area (purification)

A very conditional parameter that slightly characterizes the purpose by the size of the room. And depending on the height of the ceilings, layout, structure of the building and equipment, the actual values ​​​​may differ significantly. Nevertheless, this item represents the maximum recommended area of ​​​​the room in which the device is able to effectively clean the air. The parameter is indicated taking into account the standard ceiling height of 2.5-3 m. If the ceilings are higher than generally accepted values, the volume of space increases — it can be recalculated using special formulas. If the unit is used in rooms larger than the specifications of the model, the air cleaning quality may be poor, and maintenance and filter replacement may need to be done too often.

If the device is supposed to be moved from one room to another, when choosing, you should focus on the room with the largest area. In any case, it is recommended to take equipment with a reserve for the serviced area, but a small one – otherwise the device will cost more and may turn out to be more bulky.

Controls

The type of control provided in the device.

Note that mechanical and electronic devices can use the same elements - buttons, rotary knobs, sliders — and, as a result, almost do not differ from each other in appearance. The difference lies in the fact that the mechanical control directly affects the working part of the device (for example, when the knob is turned, the resistance of the rheostat that regulates the power changes), and the electronic control sends a signal to the control circuit, which accordingly changes the parameters of the device. The advantages of mechanical ones are simplicity, reliability and low cost. However, it allows you to adjust only basic functions, and the accuracy of the adjustments is low. In turn, with electronic control, various additional features can be provided and individual operation parameters can be very precisely adjusted. But such control is more complicated and expensive. Electronic control can also be performed in the form of touch controls, which gives the device elegance and elevates it to a more advanced level.

Air flow

Maximum performance provided by the humidifier — that is, the maximum amount of air that it can pass through itself in an hour. This parameter is most relevant for models with a purifier function (see “Type”). However, it can also be specified for humidifiers.

The flow rate is selected by manufacturers, taking into account the area and, accordingly, the volume of the room for which the device is designed. For efficient operation, the device must be able to pass the entire volume of processed air through itself at least once per hour (or better, two or three times). At the same time, for models with the same area of the room, different air flow indicators can be declared - accordingly, the processing speed and efficiency will differ.

We also note that the recommended area of the room can be estimated by air flow if the latter is not stated in the specs. For example, if the device provides 200 m³/h, this means that the volume of the room can be no more than 200 m³, which, with a standard ceiling height of 2.5 m, gives an area of 200/2.5=80 m². And ideally, the area should be even 2-3 times smaller — that is, it should be about 25-40 m².

Operating time

It is the operating time of the humidifier with a full tank. It depends on the volume of the tank and on the water consumption (see below for both). For models with humidity control (see "Features"), this parameter can be indicated in different ways: in some cases, the maximum duration of the operation is given (at the minimum output humidity), and in others — vice versa. Nevertheless, according to the declared figures, it is quite possible to estimate the operating time at least approximately.

Water consumption

The rate at which the humidifier uses water. Knowing this speed and the volume of the water tank (see below), you can determine the operating time. Also, this indicator can be used to evaluate the performance and speed of the device: the higher the water consumption, the more it evaporates into the air per unit of time. Accordingly, a high-consumption device allows you to quickly achieve the desired humidity, all other things being equal.

Note that for models with humidity control (see "Features"), the maximum consumption is most often indicated, at the highest humidity settings. And in evaporate devices(see "Type"), the claimed consumption will be achieved only with dry air (30% or less) — at higher humidity, evaporation will slow down and water consumption will decrease.

Water tank volume

The volume of the water tank installed in the humidifier. Large capacity allows you to work longer without refuelling but affects the dimensions and weight of the device. Therefore, manufacturers choose the volume based on a compromise between these points and taking into account water consumption. Usually, the volume of the tank is chosen in such a way that the humidifier can work quietly on a single refill for at least 2-3 hours, and often even more. Accordingly, the more capacious the tank, the more powerful and performant the device, as a rule. So, models with a volume of up to 2 litres belong to the entry-level, from 2 to 4 litres — to the average, from 4 to 6 litres — to the larger than average category, and in the most capacious devices this figure can exceed 6 litres .

Note that for models with the possibility of using a bottle (see below), this paragraph often indicates the optimal capacity of the bottle (such devices may not have their tanks).

Min. noise level

The noise level generated by the air cleaner when operating in low or night mode. Most of these devices are used in domestic conditions, so the noise level plays an important role, especially at night. According to sanitary standards, constant noise in such rooms should not exceed 40 dB (quiet conversation) during the day and 30 dB (wall clock ticking) at night. More detailed comparison tables and recommendations can be found in special sources.

Maximum noise level

The noise level generated by the air purifier during operation. Most of these devices are used in residential areas, so this parameter should be treated carefully. According to sanitary standards, constant noise in such rooms should not exceed 40 dB (quiet conversation) during the day and 30 dB (wall clock ticking) at night. More detailed comparison tables and recommendations can be found in special sources. It is also worth mentioning that the noise level is indicated for the maximum operating speed, so the noise level will be significantly lower in reduced mode.
Panasonic F-VXK90R often compared
Panasonic F-VXK70R often compared