USA
Catalog   /   Climate, Heating, Water Heating   /   Water Supply & Pumps   /   Water Heaters

Comparison Tesy GCV 803524D D06 TS2RC vs Tesy GCV 803524D D06 TS2R

Add to comparison
Tesy GCV 803524D D06 TS2RC
Tesy GCV 803524D D06 TS2R
Tesy GCV 803524D D06 TS2RCTesy GCV 803524D D06 TS2R
Outdated Product
from $113.20 up to $128.56
Outdated Product
TOP sellers
Typestoragestorage
Energy sourcemainsmains
Installationverticalvertical
Tank volume80 L80 L
Tank shapeslimcylindrical
Technical specs
Power source230 V230 V
Power consumption2400 W2400 W
Heating modes
/2400/1200 Вт/
Tank liningglass ceramicsglass ceramics
Water supplywith pressurewith pressure
Heating time
97 min /at ∆t=45 °C/
138 min
Magnesium anode
Heating elements
/по 1200 Вт/
2
Heating element type
dry heater
dry heater
Features
Functions
thermostat
thermostat
Safety systems
overheat protection
dry heating protection
safety valve
overheat protection
 
safety valve
General specs
Controlsmechanicalmechanical
Controls layoutbottomfront
Pipe connectionbottombottom
Tank manufacturer's warranty5 years
Dimensions (HxWxD)57x35x38 cm
116x35x38 cm /weight — 23.9 kg/
Added to E-Catalogoctober 2019december 2016

Tank shape

The shape of the water heater.

The traditional options are cylindrical and rectangular, but nowadays there are more specific options — flat cases, slim cylindrical devices. Here are the features of each of these options:

— Cylindrical. This form is traditional for storage water heaters. It is because with the same total volume, less material is needed for a cylindrical tank than for a rectangular one; and in production, such tanks are simple and cheap, which allows them to be used in water heaters of any price category. The disadvantages of this form include, first of all, some bulkiness in comparison with other options.

— Rectangular. The case is rectangular in shape, with pronounced front and side faces; the corners can be both sharply defined and rounded. It is the traditional form for instant water heaters, primarily gas, but it can be found in a fairly large number of storage models. Accordingly, the features of a rectangular case will be different — depending on the type of heater. So, in instant water heaters, the “rectangle” is simply one of the most convenient options in terms of the overall layout. But in storage water heaters, this shape differs from the flat one (see below) only with a slightly greater thickness and, in some cases, pronounced angles.

— Flat. A variant found mainly in s...torage electric heaters. Such devices look as if the classic cylindrical body was flattened at the back and front, reducing its thickness by increasing the width (and sometimes height). Thus, such a boiler does not protrude as much in front of the wall as a cylindrical one; in some cases, this point may be fundamental — for example, when installed in a bathroom, where a cylindrical device would hang over the toilet bowl, creating discomfort.

— Slim. A variety of cylindrical cases are characterized by a reduced diameter. In other words, boilers from this category are also round, but with the same volume, they have a noticeably smaller width and thickness than traditional cylindrical ones. In cramped conditions, this can be very useful. However, it must be borne in mind that the price for reducing the diameter is an increase in height.

Heating modes

The number of heating modes provided in the device.

This parameter is specified only for models with several heating modes. We emphasize that you should not confuse such functionality with temperature control (see "Features"). The heating mode is the general format of the device; these formats differ primarily in such parameters as the actual heating power, the number (and in combined models, and types) of the heating elements involved, etc. The thermostat, if it is in the design, allows you to change the temperature within a specific mode.

In general, the presence of several heating modes expands the functionality of the water heater but affects its cost. Of course, the specific features of these modes do not hurt to clarify in advance before buying.

Heating time

Time to heat the storage tank (see "Type"), filled with cold water, to operating temperature.

It is worth remembering that this characteristic is not 100% accurate. Manufacturers usually indicate the heating time for certain conditions: a filled tank, maximum heating intensity, and temperature rise (∆T) by a certain number of degrees. In practice, the heating time may differ, both one way and the other. For example, if the heating time for the device is 20 minutes at ∆T = 50 °C, then when the water is heated from 15 °C to 60 °C, the time will be shorter (∆T = 45 °C). Nevertheless, this indicator allows us to evaluate the overall flow rate of the boiler, and with equal ∆T and volumes, different models can be compared in terms of heating time.

Safety systems

The safety of water heaters can be carried out by such functions as overheat protection frost protection, dry heating protection, surge protection, electrical protection (RCD), anti-legionella, gas control and draft sensor. More about them:

— Overheat protection. Water heater safety system that automatically turns off the power supply or gas supply (depending on the type) when the heating element reaches a critical temperature. It avoids overheating and the troubles associated with it, ranging from heater failure to fire.

— Frost protection. Function to prevent freezing of water in the circuits, tank and/or heat exchanger of the water heater. It will be useful when the device is installed in a room with a low temperature and works with long breaks. Frozen water expands, which can damage the device; to avoid this, the frost protection monitors the temperature of the water in the device and turns on the heating when this temperature drops to a critical level.

— Dry heating protection. A safety system that prevents the heater from being switched on without the presence of water in it. Since the heating element does not transfer heat to the water when turned on, it heats up very q...uickly and, in a short time, reaches a high temperature that can lead to damage to the heater and even to a fire. The presence of protection against switching on without water allows you to avoid such unpleasant consequences.

— Voltage surge protection. System for protecting the heater from power surges. Electronically controlled models are usually equipped with such protection (see Control) since it is the control electronics that are most sensitive to problems with the power supply. Note that the capabilities of such systems are noticeably more modest than those of specialized stabilizers or protective systems: the “hardware” of a water heater can smooth out relatively weak power surges, but in case of serious failures, it will most likely simply turn off the device to avoid damage. However, this feature will be useful; except that in very unstable electrical grids, prone to frequent fluctuations, such a heater may require an external stabilizer.

— Electrical protection (RCD). Built directly into the heater, the RCD is a residual current device. Such a device is primarily intended to protect people from electric shock — for example, if the insulation is damaged and electricity leaks into the case or water. When a person comes into contact with this electricity, a so-called leakage current occurs. The RCD reacts to it and almost instantly turns off the power to the boiler, preventing electric shock.
Note that such safety devices are standardly installed directly in switchboards. However, the presence of an RCD in the water heater provides additional security. Naturally, such equipment is found mainly in electric models.

— Safety valve. A safety system that prevents a critical increase in water pressure in the heater. Usually, this protection is based on a safety valve that opens when a certain pressure level is reached and drains excess water, avoiding damage to the heater.

— Gas control. Gas heater safety system that automatically shuts off the gas supply in the event of a burner flame failure. It avoids filling the room with gas and possible unpleasant, and even tragic consequences. Resuming the gas supply after the protection is triggered must be done manually.

— Draft sensor. A sensor that monitors the presence of draft in the flue of a gas water heater. This function is especially important for models with open combustion chambers: in the absence of a draft, combustion products will fill the room where the heater is located. And this, in turn, can lead to a deterioration in people's well-being, health problems and even deaths. To avoid such consequences, this sensor, when detecting problems with the draft, turns off the gas supply and issues a warning about the problem. However, such equipment can also be found in models with closed combustion chambers. In them, the draft sensor performs mainly a diagnostic function, allowing you to determine what interferes with the normal operation of the burner.

— Anti-legionella. A function that prevents the growth of pathogenic bacteria in the tank and water heater circuits. Some types of such bacteria can live and multiply in fairly hot water — up to 60 °C. To avoid this, the anti-legionella system monitors the temperature of the water in the tank and periodically raises it to a level of about 65 °C. The specific methods of operation of such systems can be different: for example, some work strictly according to a set schedule (for example, once every two weeks), others turn on additional heating only if for some period (for example, a month) the water has not been heated to sufficiently high temperatures.

Controls layout

Location of heater controls. It is worth choosing by this parameter, taking into account where it is planned to install the device and from which side access to it will be most convenient. For example, when installed in cramped conditions, the water heater can only be opened from the side or the bottom; for such cases, it is worth looking for a model with the appropriate location of the controls.

Tank manufacturer's warranty

The warranty period declared by the manufacturer for the storage water heater tank (see “Type”).

This parameter is important for the reasons of maintenance terms. The tank is the most complex element: other parts of the water heater are relatively easy to repair and change, and if there is a problem with the tank, it is often easier to replace the entire boiler. In the most advanced models, the warranty on the tank can be 10 years or more.
Tesy GCV 3524D D06 TS2R often compared