USA
Catalog   /   Climate, Heating, Water Heating   /   Water Supply & Pumps   /   Water Heaters

Comparison Zanussi GWH 10 Senso vs Zanussi GWH 10 Fonte

Add to comparison
Zanussi GWH 10 Senso
Zanussi GWH 10 Fonte
Zanussi GWH 10 SensoZanussi GWH 10 Fonte
Outdated Product
from $103.40 up to $130.96
Outdated Product
TOP sellers
Main
Compactness. Display.
Typetanklesstankless
Energy sourcegasgas
Installationverticalvertical
Tank shaperectangularrectangular
Technical specs
Power sourceenergy independentenergy independent
Rated heat exchanger power20 kW18.5 kW
Performance (Δt ~25 °C)10 L/min10 L/min
Performance (Δt ~50 °C)5 L/min5 L/min
Water supplywith pressurewith pressure
Heating elements11
Heating element type
heat exchanger
heat exchanger
Ignition typebatteriesbatteries
Combustion chamber typeclosed (turbocharged)open (atmospheric)
Flue diameter110 mm110 mm
Features
Functions
thermostat
display
thermostat
display
Safety systems
overheat protection
dry heating protection
safety valve
gas control
draft sensor
overheat protection
 
 
gas control
draft sensor
General specs
Controlsmechanicalelectronic
Controls layoutfrontfront
Pipe connectionbottombottom
Dimensions (HxWxD)55x33x18.9 cm55x33x18.9 cm
Weight8.2 kg8.2 kg
Added to E-Catalogaugust 2019april 2016

Rated heat exchanger power

Rated power of the heat exchanger installed in the gas or indirect heater (see "Water heater type"), in other words, the amount of heat that can be transferred to the heated water through the heat exchanger.

This parameter is directly related to the performance of the water heater: high performance inevitably requires appropriate power. At the same time, the power of the heat exchanger is selected in such a way as to provide the necessary operating parameters (primarily performance and temperature). So when choosing a water heater, you should focus primarily on these parameters. Data on the power of the heat exchanger may be needed for some specific calculations — for example, assessing the compatibility of the heater with a boiler or solar collector: an external heat source must have no less thermal power than the heat exchanger, otherwise, it will be impossible to achieve the claimed performance.

It is also worth considering that the actual power of the heat exchanger depends on the temperature of the coolant flowing through it. In the characteristics of the water heater, usually, the power is given for the maximum allowable operating temperature; if the coolant is cooler, then the actual power will be lower.

Combustion chamber type

Type of combustion chamber of a gas water heater. Combustion chambers are divided into open and closed.

Open (atmosheric). It works according to the classical scheme: for the combustion of fuel, the air is consumed from the room in which the heater is located, and the combustion products are removed through the flue due to the natural draft. For normal operation of such a heater, the room must have good ventilation, and the flue must be at least 4 m high.

Closed (turbocharged). The closed combustion chamber draws air for combustion of the fuel from the outside, and the products of combustion are removed there. In this case, gas exchange is carried out forcibly, with the help of a fan, therefore sometimes such combustion chambers are called turbocharged. The main advantage of such heaters is that they take air for combustion from the street without burning oxygen in the room. Thus, comfortable conditions are provided in the room, and the heater itself can be installed regardless of ventilation conditions (for example, in the kitchen or the bathroom). ). However, for turbocharged chambers, there are restrictions on the maximum length of the flue.

Safety systems

The safety of water heaters can be carried out by such functions as overheat protection frost protection, dry heating protection, surge protection, electrical protection (RCD), anti-legionella, gas control and draft sensor. More about them:

— Overheat protection. Water heater safety system that automatically turns off the power supply or gas supply (depending on the type) when the heating element reaches a critical temperature. It avoids overheating and the troubles associated with it, ranging from heater failure to fire.

— Frost protection. Function to prevent freezing of water in the circuits, tank and/or heat exchanger of the water heater. It will be useful when the device is installed in a room with a low temperature and works with long breaks. Frozen water expands, which can damage the device; to avoid this, the frost protection monitors the temperature of the water in the device and turns on the heating when this temperature drops to a critical level.

— Dry heating protection. A safety system that prevents the heater from being switched on without the presence of water in it. Since the heating element does not transfer heat to the water when turned on, it heats up very q...uickly and, in a short time, reaches a high temperature that can lead to damage to the heater and even to a fire. The presence of protection against switching on without water allows you to avoid such unpleasant consequences.

— Voltage surge protection. System for protecting the heater from power surges. Electronically controlled models are usually equipped with such protection (see Control) since it is the control electronics that are most sensitive to problems with the power supply. Note that the capabilities of such systems are noticeably more modest than those of specialized stabilizers or protective systems: the “hardware” of a water heater can smooth out relatively weak power surges, but in case of serious failures, it will most likely simply turn off the device to avoid damage. However, this feature will be useful; except that in very unstable electrical grids, prone to frequent fluctuations, such a heater may require an external stabilizer.

— Electrical protection (RCD). Built directly into the heater, the RCD is a residual current device. Such a device is primarily intended to protect people from electric shock — for example, if the insulation is damaged and electricity leaks into the case or water. When a person comes into contact with this electricity, a so-called leakage current occurs. The RCD reacts to it and almost instantly turns off the power to the boiler, preventing electric shock.
Note that such safety devices are standardly installed directly in switchboards. However, the presence of an RCD in the water heater provides additional security. Naturally, such equipment is found mainly in electric models.

— Safety valve. A safety system that prevents a critical increase in water pressure in the heater. Usually, this protection is based on a safety valve that opens when a certain pressure level is reached and drains excess water, avoiding damage to the heater.

— Gas control. Gas heater safety system that automatically shuts off the gas supply in the event of a burner flame failure. It avoids filling the room with gas and possible unpleasant, and even tragic consequences. Resuming the gas supply after the protection is triggered must be done manually.

— Draft sensor. A sensor that monitors the presence of draft in the flue of a gas water heater. This function is especially important for models with open combustion chambers: in the absence of a draft, combustion products will fill the room where the heater is located. And this, in turn, can lead to a deterioration in people's well-being, health problems and even deaths. To avoid such consequences, this sensor, when detecting problems with the draft, turns off the gas supply and issues a warning about the problem. However, such equipment can also be found in models with closed combustion chambers. In them, the draft sensor performs mainly a diagnostic function, allowing you to determine what interferes with the normal operation of the burner.

— Anti-legionella. A function that prevents the growth of pathogenic bacteria in the tank and water heater circuits. Some types of such bacteria can live and multiply in fairly hot water — up to 60 °C. To avoid this, the anti-legionella system monitors the temperature of the water in the tank and periodically raises it to a level of about 65 °C. The specific methods of operation of such systems can be different: for example, some work strictly according to a set schedule (for example, once every two weeks), others turn on additional heating only if for some period (for example, a month) the water has not been heated to sufficiently high temperatures.

Controls

- Mechanical. Manual control using rotary knobs and mechanical buttons. Models with mechanical controls are inexpensive, but the control capabilities themselves are quite limited and, as a rule, include only basic functions.

- Electronic. This control is carried out using an electronic unit. Electronically controlled heaters, as a rule, have a wider range of functions than their “mechanical” counterparts; they can be programmed and equipped with a display to indicate various parameters. On the other hand, with all other characteristics being equal, such heaters are much more expensive.
Zanussi Senso often compared
Zanussi Fonte often compared