USA
Catalog   /   Computing   /   Networking   /   Switches

Comparison Edge-Core ECS3510-52T vs MikroTik CRS326-24G-2S+RM

Add to comparison
Edge-Core ECS3510-52T
MikroTik CRS326-24G-2S+RM
Edge-Core ECS3510-52TMikroTik CRS326-24G-2S+RM
Outdated ProductCompare prices 6
TOP sellers
Main
One PoE input port.
Typemanaged 2 level (L2)managed 2 level (L2)
Mountrack-mountrack-mount
MAC address table size16K
Ports
Fast Ethernet48
Gigabit Ethernet24
SFP (optics)42
Uplink2
Uplink typeSFP
Console port
Features
Control
SSH
Telnet
Web interface
SNMP
 
 
Web interface
SNMP
Basic features
DHCP server
VLAN
 
VLAN
General
PSUbuilt-inexternal
Supply voltage10 – 30 В
Operating temperature-40 °C ~ +60 °C
Dimensions (WxDxH)440x144x44 mm
Weight1650 g
Added to E-Catalogdecember 2018november 2018

MAC address table size

The maximum number of MAC addresses that can be stored in the Switch's memory at the same time. Specified in thousands, for example, 8K — 8K.

Recall that the MAC address is the unique address of each individual network device used in physical routing (at layer 2 of the OSI network model). Switches of all types work with such addresses. And it is worth choosing a switch according to the size of the table, taking into account the maximum number of devices that are supposed to be used with it (including based on the possible expansion of the network). If the table is not enough, the switch will overwrite new addresses over the old ones, which can noticeably slow down the work.

Fast Ethernet

The number of standard RJ-45 network connectors in the Fast Ethernet format provided in the design of the switch.

Fast Ethernet is the most modest of the wired connection formats over a twisted-pair network cable nowadays — it provides data transfer rates up to 100 Mbps. However, even this speed is often enough for relatively simple tasks that are not associated with large amounts of data. Therefore, this interface is still widely used in modern switches.

As for the number of connectors, it corresponds to the number of network devices that can be connected to the "switch" directly, without the use of additional equipment. In the case of Fast Ethernet, the number of connectors up to 10 inclusive is considered relatively small, from 10 to 25 — average, and the presence of more than 25 ports of this type is typical for professional-level models.

Gigabit Ethernet

The number of standard Gigabit Ethernet RJ-45 network connectors provided in the design of the switch.

As the name suggests, these connectors provide data transfer rates up to 1 Gbps. Initially, Gigabit Ethernet was considered a professional standard, and even now the real needs for such speeds arise mainly when performing special tasks. Nevertheless, even relatively inexpensive computers are now equipped with gigabit network adapters, not to mention more advanced technology.

As for the number of connectors, it corresponds to the number of network devices that can be connected to the "switch" directly, without the use of additional equipment. In the case of Gigabit Ethernet, the number of connectors up to 10 inclusive is considered relatively small, from 10 to 25 — average, and the presence of more than 25 ports of this type is typical for professional-level models. At the same time, it is worth noting that in some "switches" individual connectors of this type are combined with optical SFP or SFP + (see below). Such connectors are marked "combo" and are taken into account both in the RJ-45 count and in the SFP/SFP+ count.

SFP (optics)

The number of optical network ports of the SFP standard provided in the design of the switch. We emphasize that we are talking about "ordinary" SFPs; SFP+ data is usually listed separately.

Specifically, in switches, the marking “SFP” usually means a connector for fiber with a connection speed of 1 Gbps. Technically, this is not much compared to RJ-45 speeds; however, this connection format has a number of advantages. One of the main ones is a greater effective range: the mentioned gigabit standard used in switches works with a cable length of up to 550 m, and by the standards of fiber, this is still very little. True, the cable itself is sensitive to kinks and requires quite delicate handling; on the other hand, it is completely immune to electromagnetic interference. On the other hand, in general, the SFP format is noticeably less popular in network equipment than RJ-45; therefore, there are few ports of this type even in advanced devices. So, solutions for 2 or 4 SFP connectors are most widely used, although there are more - 6, 8, or even 10 or more. It is also worth considering that the so-called combo connectors can be used in switches, combining SFP and RJ-45; the presence of such ports is specified in the notes, they are taken into account both in the calculation of RJ-45 and in the calculation of SFP.

To clarify, Uplink inputs also often use this type of connector; however, their...number is specified separately (see below).

Uplink

The number of Uplink connectors provided in the design of the switch.

“Uplink” in this case is not a type, but a connector specialization: this is the name of the network interface through which the switch (and network devices connected to it) communicate with external networks (including the Internet) or network segments. In other words, this is a kind of "gate" through which all traffic from the network segment served by the switch is transmitted further. Uplink, in particular, can be used to connect to a similar "switch" (for horizontal network expansion) or to a higher level device (like a core switch).

Accordingly, the number of Uplink connectors is the maximum number of external connections that the switch can provide without using additional equipment. The specific type of such a connector may be different, but this is usually one of the varieties of LAN or SFP; see "Uplink type" for details.

Uplink type

The type of connector(s) used as the Uplink interface on the switch.

For more information about such an interface, see above; Here we note that the same network ports are usually used as Uplink as for connecting individual devices to the switch. Here are the main options for such connectors:

— Fast Ethernet — LAN network connector (for twisted pair cables) supporting speeds up to 100 Mbit/s. This speed is considered low by modern standards, while the Uplink port places increased demands on throughput - after all, traffic from all devices served by the switch passes through it. Therefore, in this role, Fast Ethernet ports are used mainly in inexpensive and outdated models.

— Gigabit Ethernet — LAN connector supporting speeds up to 1 Gbit/s. This speed is often sufficient even for a fairly extensive network, while the connectors themselves are relatively inexpensive.

— 2.5 Gigabit Ethernet — LAN connector supporting speeds up to 2.5 Gbit/s.

— 10Gigabit Ethernet — LAN connector supporting speeds up to 10 Gbit/s. Such features allow you to work comfortably even with very large volumes of traffic, but they significantly affect the price of the switch. Therefore, this option is rare, mainly in high-end models.

— SFP. A connector for a fiber optic cable that supports speeds of about 1 Gbit/s. At the same time, over Gigabit Ethernet, which has a similar throughput, this connector has one noticeable advantage - a...longer connection range (usually up to 550 m).

- SFP+. Development of the SFP standard described above. Switches usually provide a connection speed of 10 Gbit/s; like the original standard, it noticeably exceeds the effective range of an Ethernet connection. On the other hand, the real need for such speeds does not arise so often, and SFP+ is quite expensive. Therefore, the presence of such Uplink connectors is typical mainly for high-end models with a large number of ports.

- SFP28. Another development of SFP with increased throughput up to 25 Gbit/s.

- QSFP / QSFP+. The fastest SFPs up to 40 Gbit/s.

Note also that the connectors described above (except perhaps Fast Ethernet) are rarely used as the only type of Uplink input. Combinations of electrical and fiber optic ports—SFP/Gigabit Ethernet and SFP+/10Gigabit Ethernet—have become noticeably more widespread. This provides versatility in connection, allowing you to use the most convenient type of cable in a given situation; and if necessary, of course, you can use all Uplink inputs at once. However, it is worth considering that in some models, Ethernet and SFP interfaces can be combined in one physical connector. So before purchasing, it doesn’t hurt to clarify this nuance separately.

There are also switches that use a combination of two types of SFP - SFP/SFP+; however, there are few such models and they are mainly of the professional level.

Control

Management methods and protocols supported by the switch.

SSH. Abbreviation for Secure Shell, i.e. "Safe shell". The SSH protocol provides a fairly high degree of security, because. encrypts all transmitted data, including passwords. Suitable for managing almost all major network protocols, but requires a special utility on the host computer.

Telnet. A network management protocol that provides configuration using a text-based command line. It does not use encryption and does not protect transmitted data, and is also devoid of a graphical interface, which is why in many areas it has been supplanted by more secure (SSH) or more convenient (web interface) options. However, it is still used in modern network equipment.

Web interface. This function allows you to open the management interface of the switch in a common Internet browser. The main convenience of the web interface is that it does not require additional software — a browser is enough (and it is available in any "self-respecting" modern OS). Thus, knowing the device address, login and password, you can manage the settings from almost any computer on the network (unless, of course, otherwise specified in the access parameters).

SNMP. Abbreviation for Simple Network Management Protocol, i.e. "simple network control protocol". It is a stan...dard part of the common TCP/IP protocol on which both the Internet and many local networks are built. It uses two types of software — "managers" on control computers and "agents" on managed computers (in this case, on a router). The degree of security is relatively low, but SNMP can be used for simple management tasks.

Note that this list is not exhaustive — modern switches may provide other management options, for example, support for proprietary utilities and special technologies from the same manufacturer.

Basic features

DHCP server. A feature that makes it easy to manage the IP addresses of devices connected to the switch. Without its own IP address, the correct operation of the network device is impossible; and DHCP support allows you to assign these addresses both manually and fully automatically. At the same time, the administrator can set additional parameters for the automatic mode (range of addresses, maximum time for using one address). And even in fully manual mode, work with addresses is performed only by means of the switch itself (whereas without DHCP, these parameters would also have to be specified in the settings of each device on the network).

Stacking support. The ability to operate the device in stack mode. A stack consists of several switches that are perceived by the network as one “switch”, with one MAC address, one IP address, and with a total number of connectors equal to the total number of ports in all involved devices. This feature is useful if you want to build an extensive network that lacks the capabilities of a single switch, but do not want to complicate the topology.

Link Aggregation. Switch support for link aggregation technology. This technology allows you to combine several parallel physical communication channels into one logical one, which increases the speed and reliability of the connection. Simply put, a switch with such a fun...ction can be connected to another device (for example, a router) not with one cable, but with two or even more at once. The increase in speed in this case occurs due to the summation of the throughput of all physical channels; however, the total speed may be less than the sum of the speeds — on the other hand, combining several relatively slow connectors is often cheaper than using equipment with a more advanced single interface. And the increase in reliability is carried out, firstly, by distributing the total load over individual physical channels, and secondly, by means of "hot" redundancy: the failure of one port or cable can reduce the speed, but does not lead to a complete disconnection, and when the channel is restored, the channel is switched on automatically.
Note that both the standard LACP protocol and non-standard proprietary technologies can be used for Link Aggregation (the latter is typical, for example, for Cisco switches). In addition, there are quite a few alternative names for this technology — port trunking, link bundling, etc.; sometimes the difference is only in the name, sometimes there are technical nuances. All these details should be clarified separately.

VLAN. Support of the VLAN function by the switch — virtual local area networks. In this case, the meaning of this function is the ability to create separate logical (virtual) local networks within the physical "local area". Thus, it is possible, for example, to separate departments in a large organization, creating for each of them its own local network. The organization of VLAN allows you to reduce the load on network equipment, as well as increase the degree of data protection.

— Protection against loops. The switch has a loop protection function. The loop in this case can be described as a situation where the same signal is launched in the network in an endless loop. This may be due to incorrect cable connection, the use of redundant links and some other reasons, but anyway, such a phenomenon can “put down” the network, which means it is highly undesirable. Security prevents loops, usually by disabling looped ports.

— Limiting the speed of access. The ability to limit the data exchange rate for individual switch ports. Thus, it is possible to reduce the load on the network and prevent the "clogging" of the channel by individual terminals.

Note that the matter is not limited to this list: other features may be found in modern switches.

PSU

— Built-in. The built-in power supply does not take up space on the outside, but can significantly increase the size and weight of the entire switch. Because of this, this option is quite rare — mainly among rack-mount models (see "Form factor"), where an external unit can create significant inconvenience, as well as among the most powerful desktop switches, for which restrictions on dimensions and weight is not critical.

— External. Theoretically , an external power supply requires additional space, and therefore is not as convenient as an internal one. In fact, most blocks of this type are quite compact in size and are equipped with “plugs” for sockets right on the case — in other words, the block is installed on a socket, and from there the wire stretches to the switch. And the absence of power circuits and transformers inside the case has a positive effect on compactness. Thanks to all this, this option is very popular among desktop models (see "Form factor"), primarily entry-level and mid-level.

— No BP. The absence of a power supply both in the design and in the delivery set is a rather rare case found in three types of switches. The first variety is models that use PoE power (see above) and do not require separate power sources. PoE power is relatively small, so relatively simple devices with a small number of ports fall into this category. The second variety is professional switc...hes, the power supplies for which are sold as separately installed internal modules; such equipment may even provide the possibility of using two PSUs simultaneously (main and backup) and hot-swapping them. The third type — switches with installation on a DIN rail (see "Form factor") and having terminals for connecting a specialized external power source.
MikroTik CRS326-24G-2S+RM often compared