USA
Catalog   /   Small Appliances   /   Health & Rehabilitation   /   Clinical Thermometers

Comparison Omron Gentle Temp 720 vs BabyOno 115

Add to comparison
Omron Gentle Temp 720
BabyOno 115
Omron Gentle Temp 720BabyOno 115
from $64.00 up to $68.22
Outdated Product
from $39.48 up to $49.68
Outdated Product
TOP sellers
Main
Measurement of liquid temperature and air temperature in the room. Memory for 25 readings. Disabled sound notifications. Informative backlit display. Ergonomic design.
Typeinfraredinfrared
Application area
frontal
frontal
Measurements
Air temperatures
Liquid temperatures
Measurement duration1 sec1 sec
Measurement range0 – 100 °C32-43 °C
Measurement accuracy0.2 °C0.3 °C
General
Reading memory25 pcs32 pcs
Sound signal
Display backlight
Power source1xCR2032
Added to E-Catalogmarch 2016february 2016

Air temperatures

Possibility of using a thermometer to measure the air temperature. Usually, such a measurement is carried out by a separate sensor, due to which this function is found not only in contact, but also in IR thermometers (see "Type").

Liquid temperatures

The ability to measure the temperature of liquids using a thermometer. The method of such measurement can be both contact and non-contact. One of the most popular uses for this feature is when preparing baby food.

Measurement range

The range of temperatures that a thermometer can measure.

For measuring body temperature, a range of 35 – 43 °C is considered ample, covering values encountered in individuals with high fever or hypothermia. Although modern medical thermometers may have broader ranges, especially those designed for water and air temperature measurement (e.g., -20 – 100 °C), when used for body temperature, they typically operate within a narrower range. The overall and "solid" measurement ranges are often specified separately in these thermometers.

Measurement accuracy

The extent to which a device deviates from the actual temperature during measurements determines its accuracy. Even the least accurate electronic medical thermometers today have a maximum deviation of 0.3 °C, sufficient for everyday and basic medical use. Common models offer even higher accuracy, with deviations as low as 0.1 °C or 0.2 °C, making the pursuit of maximum accuracy necessary only in specific scenarios.

Reading memory

The number of results the thermometer can store in memory. The ability to "remember" the results of previous measurements can be very convenient in some cases — in particular, it allows you to accurately track changes in temperature over time. The most advanced models are capable of storing several dozen readings in memory.

Sound signal

The presence of a sound signal in the thermometer. Most often, such a signal indicates the end of the measurement, which eliminates the need to independently monitor the time or get a device to check the readings. However, other events can also be accompanied by sounds, such as switching on and off.

Power source

Type of batteries used in thermometers.

— AA. The ubiquitous battery, commonly found everywhere batteries are sold, operates at 1.5 volts, making it widely accessible.

— AAA. The batteries, which are a compact alternative to AA batteries with the same 1.5V voltage, are widely used and suitable for small devices.

— CR2032. One of the most popular types of batteries, with a diameter of 20 mm and a thickness of 3.2 mm. Actual for use in compact devices.
Omron Gentle Temp 720 often compared
BabyOno 115 often compared