Comparison Gorenje BVX W BVX 100 WS vs Gorenje BVN W BVN 100 WS

Add to comparison
Gorenje BVX W (BVX 100 WS)
Gorenje BVN W (BVN 100 WS)
Gorenje BVX W BVX 100 WSGorenje BVN W BVN 100 WS
from $19.56 up to $29.00
Outdated Product
from $18.58 up to $20.40
Outdated Product
TOP sellers
Typedomestic extractiondomestic extraction
Mounting diameter100 mm100 mm
Specs
Air flow (extraction)70 m³/h70 m³/h
Rotational speed2450 rpm2450 rpm
Supply voltage230 V230 V
Power consumption15 W15 W
Features
non-return valve / shutters
non-return valve / shutters
General specs
Noise level30 dB33 dB
Protection levelIPX4IPX4
Country of originChinaChina
Perimeter suction
Cover height150 mm150 mm
Cover width150 mm150 mm
Cover thickness21 mm17 mm
Mounting depth (duct)72 mm55 mm
Color
Added to E-Catalognovember 2015november 2015

Noise level

The noise level reproduced by the fan in normal operation.

The lower the noise level, the more comfortable the use of the fan will be, the better it is suitable for rooms in which it is desirable to keep silence. In addition, there are certain regulations written in sanitary standards (for example, for residential premises during the day, a constant noise level of up to 40 dB is considered acceptable, and at night — up to 30 dB).

When choosing according to specific values recorded in the characteristics, it should be taken into account that the decibel used to measure the noise level is not a linear quantity: for example, an increase in sound power by 2 times corresponds to an increase of 3 dB, 10 times — by 10 dB, 100 times — by 20 dB. Therefore, to assess the noise level, it is easiest to refer to comparative tables, where the correspondence of specific values in decibels to various real sound sources is recorded. In most modern fans, noise is between 20 and 60 dB, here is the simplest table for this range:

20 – 25 dB — a weak audible sound, comparable to a whisper at a distance of 1 – 2 m;
25 – 30 dB — intelligible whisper at a short distance, ticking of a wall clock;
35 dB — muffled conversation;
40 – 45 dB — normal human speech;
50 – 55 dB — talking in raised tones, noise in the office;
60 dB — loud conversation at a distance of several metres.

Note that patter...ns over 50 dB are rare; usually, these are “industrial” class units with a 400 V power supply and a large mounting diameter (see above), not intended for residential premises.

Perimeter suction

A suction system that draws in air through a series of holes around the perimeter of the air intake. This design provides high suction efficiency and, at the same time, allows you to apply advanced design solutions to the device. Perimeter suction is characteristic mainly of models of the upper price range.

Cover thickness

The size of the decorative fan cover in thickness.

This parameter describes how much such a panel protrudes above the surface of the wall or ceiling on which the fan is installed. For more information about the general features of decorative panels in different types of fans, see "Cover diameter".

Mounting depth (duct)

Mounting depth of the fan with a standard installation method.

This parameter describes how deep into the duct the unit (or its parts in the case of surface-mounted models, see "Type") is placed during installation. Knowing the mounting depth, it is possible to assess the suitability of the selected model for a particular installation location: a flat section at the very beginning of the duct must be no less than the installation depth of the selected fan.

The smallest value of this parameter is typical for some overhead models of fans: in them, the main part of the structure is outside, and usually, only 2-3 centimetres are required for installation. And most of all, hidden units require space (see "Type").
Gorenje BVX W often compared