Comparison Ballu BHP-PE-3 vs Ballu BHP-M-3

Add to comparison
Ballu BHP-PE-3
Ballu BHP-M-3
Ballu BHP-PE-3Ballu BHP-M-3
from $57.24 up to $66.80
Outdated Product
from $76.96 up to $95.40
Outdated Product
TOP sellers
Power supplyelectricelectric
Max. thermal output
3 kW /1.5 kW/
3 kW /1.5 kW/
Max. heating area30 m²30 m²
Increase in air temperature (ΔT)39 °C30 °C
Specs
Supply voltage230 V230 V
Rated current13.6 А13.6 А
Power consumption30 W
30 W /ventilation mode/
Heating elementtubular heatertubular heater
Airflow230 m³/h300 m³/h
Power adjustment
stepped
stepped
Max. operating time24 h
Features
thermostat
fan mode
thermostat
fan mode
Safety features
overheat protection
overheat protection
More cpecs
Tilt adjustment
Protection class (IP)2020
Dimensions (WxHxD)245x315x250 mm280x390x220 mm
Weight3.7 kg3.9 kg
Added to E-Catalogoctober 2015november 2014

Increase in air temperature (ΔT)

This parameter describes the difference between the air temperature at the inlet to the heater and the outlet temperature — in other words, by how many degrees the air temperature rises when passing through the unit. The higher ΔT, the hotter the outgoing air will be and the more attentively it is necessary to observe safety measures (do not place the device near flammable and heat-sensitive materials, prevent people from being in the immediate vicinity of the gun exit, etc.).

Airflow

The maximum amount of air that an industrial heater can pass through itself in a certain time.

This parameter is associated with an increase in air temperature (see above): at constant power, higher performance usually corresponds to a smaller temperature difference. Accordingly, a more efficient industrial heater will heat the entire volume of the room faster, but the heating temperature will be lower. So, it is worth choosing according to this parameter, taking into account what is more important for you — a large temperature difference or a high heating rate.

Max. operating time

The longest time during which the industrial heater can work without interruption.

The value of this parameter depends on the power supply (see above). So, in diesel models, the operating time is usually indicated on one full tank, without refuelling. Note that this implies operation at the lowest power, with minimal fuel consumption, and in optimal environmental conditions. Therefore, when choosing a diesel heat gun for this parameter, it is worth taking a certain margin, or better, separately calculating the operating time at the highest fuel consumption: for this, the volume of the tank (see above) must be divided by the maximum consumption. If we are talking about a gas or electric model, then the maximum operating time usually means the time during which the unit can work without overheating.

Regardless of the type, the long maximum run time provides additional convenience when working with an industrial heater. At the same time, it does not always make sense to pursue the maximum value of this parameter: in fact, the need for continuous heating for a long time occurs quite rarely. In addition, many diesel models allow refuelling right during operation (and in others, the refueling break usually does not exceed a few minutes). Therefore, it is worth specifically looking for a heat gun with a long time of continuous operation only if such a feature is fundamentally important to you.

Tilt adjustment

The ability to change the tilt angle of the industrial heater. Thanks to this, you can adjust the direction of the air flow not only horizontally (by turning the unit), but also vertically — for example, direct heat to the wall section that needs to be dried first.