USA
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Circulation Pumps

Comparison Halm HUPA 25-4.0U-180 4 m
1 1/2"
180 mm
vs Wilo Star-RS 25/4 4 m
1 1/2"
180 mm

Add to comparison
Halm HUPA 25-4.0U-180 4 m 1 1/2" 180 mm
Wilo Star-RS 25/4 4 m 1 1/2" 180 mm
Halm HUPA 25-4.0U-180 4 m
1 1/2"
180 mm
Wilo Star-RS 25/4 4 m
1 1/2"
180 mm
from $47.88 up to $59.00
Outdated Product
from $51.92 up to $90.10
Outdated Product
TOP sellers
Main functioncentral heatingcentral heating
Designsingle headsingle head
Pump typecentrifugalcentrifugal
Rotor typewetwet
Specs
Max. flow2750 L/h4000 L/h
Max. head4 m4 m
Max. operating pressure11 bar10 bar
Minimum fluid temperature2 °С-10 °С
Max. fluid temperature110 °С110 °С
Features
3 speeds
3 speeds
Motor
Max. power consumption44 W
48 W /38/28 Вт/
Mains voltage230 V230 V
Shaft arrangementhorizontalhorizontal
Shaft materialcermetstainless steel
Connection
Connection typethreadthread
Inlet/outlet arrangementcoaxiallycoaxially
Inlet1 1/2"1 1/2"
Outlet1 1/2"1 1/2"
More specs
Pump housing materialcast ironcast iron
Impeller materialplasticplastic
Country of brand originGermanyGermany
Protection classIP44IP44
Insulation classH
Port-to-port length180 mm180 mm
Dimensions (HxWxD)98x180x145 mm100x140x180 mm
Weight2.7 kg2.5 kg
Added to E-Catalogjune 2015november 2014

Max. flow

The maximum flow of a pump is the amount of liquid it can pump in a certain amount of time.

Features of choosing the optimal performance option depend primarily on the purpose of the pump (see above). For example, for DHW recirculation models, the pump performance should not exceed the performance of the water heater. If the water heater is capable of delivering 10 litres per minute to the DHW circuit, then the maximum pump performance will be 10*60=600 L/h. The basic formula for calculating the performance of a heating system takes into account the power of the heater and the temperature difference at the inlet and outlet, and for the cold water system — the number of points of water intake. More detailed information about the calculations for each application can be found in special sources, and it is better to entrust the calculations themselves to professionals.

Max. operating pressure

The highest pressure in the circuit at which the pump will be able to work normally.

Of course, this parameter cannot be exceeded — the unit may fail due to a breakdown caused by too high pressure (and even if this did not happen right away, it can happen at any time). However, it is worth choosing a model with some margin — so that the pump can normally withstand pressure surges, which are almost inevitable in any pipe.

Minimum fluid temperature

The lowest fluid temperature at which the pump is capable of operating normally.

Almost all pumps can normally transfer cool water, regardless of the purpose (see above); therefore, for normal household use, this parameter is not critical and for some models, it may not be indicated at all. But if you need the ability to work with liquids with temperatures below 15 °C, you should pay close attention to the minimum temperature. Some models that can be used with antifreeze normally tolerate even temperatures below zero.

Max. power consumption

The electrical power consumed by the pump during normal operation and maximum performance.

This indicator directly depends on performance — after all, for pumping large volumes of water, an appropriate amount of energy is needed. And the power depends on two main parameters — electricity consumption and the load on the power grid, which determines the connection rules. For example, pumps with a power of more than 5 kW cannot be connected to ordinary household sockets; more detailed rules can be found in special sources.

Shaft material

It is the material from which the motor shaft in the pump is made.

— Cermet. It is a material that combines metals and their alloys with non-metallic components. In modern pumps, different types of cermets can be used, differing in price and quality; usually, the features in each case directly depend on the price category of the unit. However, it is well suited for household models with relatively low performance but is poorly suitable for professional use. Therefore, in pumps of more than 15,000 litres per hour, cermet shafts are rarely used.

— Stainless steel. This material is highly durable and reliable, due to which it is found in almost all categories of pumps — from relatively simple to professional, the performance of which is in the tens of thousands of litres per hour. However, it is somewhat more expensive than cermets.

Insulation class

The heat resistance class of the insulating materials used in the construction of the pump. The higher the heat resistance — the more reliable the device, the less likely it is to ignite or break the insulation in case of overload or overheating. In addition, powerful performant units can become very hot even in normal operations.

In modern pumps, mainly the following classes of insulation are found:

— B. Materials with a heating limit of 130 °C. They are the most modest option by the standards of pumps. Use binding and impregnating compositions of organic origin.

— F. For this class, the heating limit is 155 °C — the average for pumps. Such insulation uses mainly synthetic binders.

— H. Insulating materials based on organosilicon binders/impregnators. Due to this, their heat resistance reaches 180 °C.
Wilo Star-RS 25/4 often compared