USA
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Radiators

Comparison Royal Thermo Vittoria 500/80 12 vs Nova Florida Desideryo B3 500/100 14

Add to comparison
Royal Thermo Vittoria (500/80 12)
Nova Florida Desideryo B3 (500/100 14)
Royal Thermo Vittoria 500/80 12Nova Florida Desideryo B3 500/100 14
from $8.00
Outdated Product
from $101.19 up to $115.92
Outdated Product
TOP sellers
Radiator typesectionalsectional
Country of originRussiaItaly
Technical specs
Materialbimetallicaluminium
Number of sections1214
Mountingwallwall
Connectionsideside
Pipe centre distance500 mm500 mm
Connection size1/2"1"
Heat output1920 W2492 W
Radiator height560 mm557 mm
Radiator width960 mm1120 mm
Radiator depth80 mm97 mm
Weight19.8 kg
Added to E-Catalogapril 2016february 2016

Country of origin

The country of origin of the brand.

In most cases, either the homeland of the brand or the location of the manufacturer's headquarters is indicated as the country of origin. Production facilities may well be located in another country. However, it is worth noting here that most of the national stereotypes nowadays are unfounded — the quality of products depends not so much on geography but on the characteristics of the organization of the production process in a particular company. So from this point of view, when choosing, you should focus primarily on the reputation of a particular manufacturer. It makes sense to pay attention to the country of origin of the brand if you fundamentally want (or do not want) to support a company from a certain state.

Nowadays, the production of radiators is mainly carried out by companies from such countries: England, Belarus, Belgium, Germany, Holland, Spain, Italy, China, Norway, Poland, Turkey, Ukraine, Finland, Czech Republic.

Material

The main material used in the design of the radiator.

The most popular nowadays are steel products. Aluminium is also quite common, including in combination with copper; this material is mainly used in convectors (see "Type"), although it is also found among traditional radiators. Rarer options are bimetallic and cast iron. Here is a more detailed description of each of these materials:

— Steel. Relatively inexpensive, but at the same time quite practical material, resistant to corrosion and has good thermal conductivity. The main disadvantage of steel radiators is considered to be low operating pressure and sensitivity to water hammers — this is due to the presence of weak points in the welds. However, the specific reliability of such products may be different, depending on the quality and special solutions used in the design. Nevertheless, in general, such models are inferior to aluminium and, even more so, bimetallic ones in terms of strength. So the main scope of their application is autonomous systems with low pressure, as well as high-rise buildings up to 9 floors high. Also, steel devices are somewhat heavier than aluminium ones; however, this point is rarely critical.

— Aluminium. A material with excellent specs— in particular, it has very low thermal inertia and low weight. In addition, these radia...tors are considered to be less sensitive to water hammers than steel radiators and are better suited for high-pressure heating systems used in apartment buildings. As for the disadvantages, in addition to the relatively high cost, it is worth mentioning the demanding quality of the heating medium: it must have a neutral pH, otherwise, a reaction with hydrogen evolution is possible (which adversely affects the radiator and can lead to clogging). It is also worth considering that not all aluminium devices are designed for high pressure; this point needs to be specified separately.

— Copper/aluminium. A combination used exclusively in convectors: copper tubes for the heating medium, supplemented with aluminium plates (and, most often, an aluminium body). Copper has high reliability, including resistance to pressure drops, as well as good thermal conductivity; and the use of aluminium allows to reduce the cost and weight of the structure without sacrificing specs.

— Bimetallic. The combination of aluminium with another metal — steel, occasionally copper. The outer shell is made of aluminium in such products, the inner pipes are made of steel. This design allows to achieve of excellent efficiency combined with high strength and reliability; it is bimetallic radiators that are considered the best option for heating systems in apartment buildings, where there is a high probability of water hammers, and the standard operating pressure for such products usually turns out to be quite high.
The main disadvantage of bimetal is a rather significant cost. Thus, so-called pseudo-bimetallic (semi-bimetallic) radiators can be found on the market — only vertical channels connecting the upper and lower pipes are made of steel. It allows you to reduce the price, but it negatively affects reliability — in terms of operational features, such products are closer to aluminium ones (see above).

— Cast iron. A traditional material for heating radiators, which, however, is rare nowadays. It is due both to the large weight and bulkiness of this material and to significant thermal inertia, which does not allow you to quickly adjust the heating intensity. In addition, cast iron is quite brittle and does not tolerate water hammers. On the other hand, this material is resistant to corrosion, and the mentioned inertia in some cases turns out to be an advantage: so, even after turning off the heating, the batteries remain warm for a long time. And some cast iron products have an original appearance that fits perfectly into retro-style interiors.

Number of sections

The number of individual sections provided in the radiator of the corresponding design (see "Type"). We are talking about the delivery set: the whole radiator is assembled from separate sections, and it is not even necessary to use them all.

The number of sections in itself does not affect the performance of the product. However, this information may be useful when assembling a radiator of a certain thermal power (see "Heat output"). So, by dividing the total heat output of this model by the number of sections, you can determine the specs of one section and calculate how many of them are needed to provide the desired heat output. However, a fairly large number of modern radiators are initially sold in one section — just so that the user can assemble the battery at his discretion. For finished products, 2 – 5 sections is considered a rather modest indicator, 6 – 10 pcs — average, 11 – 15 pcs — above average, and models for 16 – 20 sections or more can have both horizontal and vertical layouts (in the latter case, sections placed one on top of the other, like the floors of a tower).

Connection size

The diameter of the thread used to connect the radiator to the heating system. Modern radiators use standard sizes — for example, 3/4" or 1/2", less often 1" and 1 1/4". This indicator must match the dimensions of the pipes, couplings and other elements directly used for connection — otherwise, at best, you will need to install adapters, and at worst, the radiator will turn out to be unusable at all.

Usually, the larger the thread diameter, the more powerful the radiator (high power requires intensive circulation of the heating medium and an appropriate throughput at the inlet and outlet).

Heat output

The rated thermal output of the radiator is the amount of heat given off to the air in normal operation.

When choosing this parameter note that the heat output will depend on the temperature difference at the inlet and outlet to the radiator, as well as on the ambient temperature. The greater the temperature difference and the colder it is around, the more intense the heating will be. Therefore, in the specs, it is customary to indicate heat transfer for certain standard conditions. In particular, the designation according to the European standard EN-442 is very popular, which assumes heating medium temperatures of +75 °С and +65 °С at the inlet and outlet, respectively, as well as an air temperature of +20 °С. Real conditions and the actual heat output of the radiator may differ; therefore, when choosing, it is best to choose a model with a certain margin and compensate for excess power with one or another regulator. As for the actual values, in the most modest models, the heat outputdoes not exceed 750 W, or even 500 W, and in the largest, this figure can reach 3.5 – 4 kW or more.

The choice for this parameter depends primarily on the size and specs of the heated space. The simplest calculation formula is as follows: at least 100 W of thermal power is required per 1 m2 of area. This formula is relevant for standard r...esidential/office premises with ceilings of 2.5 – 3 m, without problems with thermal insulation; for more specific conditions, there are more detailed calculation methods, that can be found in special sources.

Radiator height

Radiator height. The most widespread nowadays are standard height sizes: 30 cm, 40 cm, 50 cm, 60 cm and 90 cm. In addition, you can find other options (although much less often) — 20 cm, 45 cm, 55 cm, 70 cm, 75 cm and 80 cm.

Firstly, the height of the product primarily determines the size of the space required for installation. At the same time, for models placed in a niche (see "Mounting"), this dimension actually corresponds to the required depth of this niche. In other cases, it is worth taking a certain margin in height — the radiator cannot be installed close to the floor and window sill (or other similar items). And models with a bottom connection (see above) will require additional space for the pipe connection.

Secondly, this size determines heat output: all other things being equal (including the size in width), a higher radiator will have a larger working surface area and a higher heat output (this is also true for heat exchangers in convectors). Thus, modern radiators are traditionally produced not in separate models, but in series of the same type of devices that differ onl...y in size and thermal power.

Radiator width

Radiator width.

In modern models, this size can be from 10 cm or even less(in separately sold sections from sectional radiators, see "Type") to 2.5 m or more(in the largest panel products and convectors). At the same time, the design uses mainly standard widths — their list is very extensive, it mainly includes options in increments of 10 cm: 30 cm, 40 cm, 50 cm, 60 cm, 70 cm 80 cm, 90 cm, 100 cm, 110 cm, 120 cm, 130 cm, 140 cm, 150 cm etc. The actual dimensions may differ slightly from the standard, but this difference does not exceed 1 cm: for example, the category "60 cm" includes models with a width of 590 to 610 mm.

The width determines two features of the radiator at once: the size of the space required for installation, as well as heat output. In the first case, everything is quite obvious; we only note that the radiator heater should be placed close to surrounding objects so that it's ok to take a certain margin in width (and if the pipes are c...onnected sideward, it is worth considering the space required for them). As for heat output, other things being equal, a wider device will have a larger working surface area and a higher heat output (this is also true for heat exchangers in convectors). Thus, modern radiators are traditionally produced not in separate models, but in series of the same type of devices that differ only in size and thermal output.

Radiator depth

The size of the radiator from the front to the back wall.

This parameter determines both the size of the space occupied by the device and its efficiency: other things being equal, a greater depth means a higher heat output (due to an increase in the area of contact with air). Specific nuances depend on the type of radiator and the method of its installation (see above). So, the most critical depth is for convectors with a horizontal layout, mounted in a niche — in them, this size directly determines both the required dimensions of the niche and the area of the working surface. In column models, this dependence is somewhat less pronounced. In panel devices, the efficiency depends not so much on the depth as such, but on the number of working elements (see "Type (panel)") — although a larger number of panels/convectors inevitably affects the dimensions. And sectional radiators most often have a relatively small depth: the differences between them in this parameter are not fundamental.
Royal Thermo Vittoria often compared
Nova Florida Desideryo B3 often compared