Liebherr SIGN 3566
Liebherr SIGN 3556
Liebherr SIGN 3566Liebherr SIGN 3556
from $1,298.84 up to $1,880.01
Outdated Product
from $1,162.18 up to $1,679.91
Outdated Product
TOP sellers
Main
Electronic control with touch buttons, FrostSafe containers. Lateral wall heating. Door closer SoftSystem. Spatial layout for large VarioSpace products. Child protection. Low power consumption class A++.
Product typefreezerfreezer
Capacity205 L213 L
No Frost
Number of compartments88
Telescopic rails
 /6 pcs/
Features
Minimum temperature-24 °C-24 °C
Power failure autonomy34 h14 h
Freeze capacity18 kg/day18 kg/day
Fast freeze
Ice maker
Lighting
Reversible door
Door closer
 /SoftSystem/
Door alarmsound and opticalsound
More specs
Controlspush-buttonstouch controls
Display
Child lock
Cold accumulators2
Energy classA++A++
Energy consumption per year240 kWh222 kWh
Climate classSN, N, ST, T (+10...+43 °С)
Noise level38 dB37 dB
Door panel hingerigid mountrigid mount
Dimensions (HxWxD)177x56x55 cm177x56x54.4 cm
Embedded dimensions (HxWxD)1772x560x550 mm1772x560x550 mm
Weight72 kg
Country of originGermany
Added to E-Catalogjune 2014june 2014

Capacity

It is the total working capacity of the freezer. A larger capacity allows you to accommodate more products but affects the dimensions and cost of the unit. Therefore, when choosing according to this parameter, you should not chase after the maximum capacity but the capacity you really need. For example, the average required capacity is 50 litres per person. And when choosing a display chest freezer (see "Product type"), you need to take into account the number of products offered for sale.

It is also worth considering that the freezer is often divided into several compartments (see below) - which means that a large capacity does not guarantee that large pieces of food can fit in the device.

Power failure autonomy

The amount of time the freezer keeps food cold enough when the refrigeration system is turned off, for example, due to a breakdown or power outage. Technically, the power failure autonomy for each model is calculated differently; For example, for a freezer with an operating temperature of -18 ° C, this is the period during which the products in the chamber heat up from -18 ° C to -9 ° C. To sum up, the time is indicated during which the frozen products are guaranteed not to heat up to a temperature at which they could lose their properties.

Ice maker

It is a separate device for producing edible ice in the freezer. One of the advantages of such freezers is that the ice is produced and stored separately from other products and thus does not absorb foreign odours.

Door alarm

It is a system that monitors the closing of the freezer door. If the door is not closed for a long time or is not closed tightly enough, an audible or light (depending on the model) signal is given. It helps to avoid a critical increase in temperature in the working chamber and preserves the quality of the products.

Controls

The type of control provided in the freezer. This parameter is specified by the type of controls and their location.

- Rotary knobs. In general, this is the simplest and most inexpensive option used in units of the appropriate level. However, even this is quite enough - especially if the freezer works in more or less constant temperature conditions (for example, in a home or office kitchen). In many cases, the matter is limited to selecting the appropriate knob position once and then not changing the settings. In addition, the major advantages of this type of control are reliability and ease of repair.

- Push-buttons. Push-buttons are considered more advanced than rotary knobs. The specific functionality of freezers with such a control may be different. But among them, models with additional functions and the ability to fine-tune the temperature are noticeably more common. As for the location, there are internal and external push-buttons. The internal location allows you to hide the control panel behind the refrigerator door, providing a neat appearance with a minimum of protruding parts.
The external location is convenient because you do not need to open the door to access the settings. On the other hand, the real need for such an arrangement is not so often, and the control panel must also fit into the overall design of the unit (which is not always possible to do in the best way).

- Touch controls. Touch controls are considered th...e next step in the development of control panels, after buttons. So, it looks stylish and technologically advanced, they do not need to be pressed hard (just touched), and there are no protruding parts, corners or slots on the surface of the panel, which simplifies cleaning from dirt. The presence of a touch panel is typical mainly for models of the middle and top levels. It costs a little more than a push-button one, but this is imperceptible against the total price of the units. But the internal location, in this case, is much less common than the external one. It is because there is no need to hide the touch panel behind the door. It can easily fit into the design of the device. In addition, external placement allows you not to open the door again to access the settings.

Child lock

The child lock allows you to block freezer controls and/or access to its internal volumes. This function will be useful in families where there are small children. Thus, the child will not be able to get to the freezer controls and change its operation mode.

Cold accumulators

The presence of removable refrigerants (cold accumulators) in the freezer design. This solution allows you to extend the temperature retention time in case of a power outage and also allows you to take it with you for use outside the freezer if necessary.

Energy consumption per year

It is the average amount of energy consumed by the freezer in a year of operation. Of course, these figures are not absolutely accurate. The actual power consumption may vary depending on the specific operating conditions. However, this parameter makes it possible to evaluate the consumption of the device and compare different models with each other. At the same time, it often turns out to be more convenient and visual than the energy consumption class (see above) because, in this paragraph, we are talking about a specific figure (from which you can also calculate the cost of electricity consumed).

Climate class

The climate class to which the freezer corresponds.

As the name implies, this parameter describes the environmental conditions for which the unit is designed. The warmer it is around, the more powerful the freezer should be and the better thermal insulation it should have. Specific classes are indicated by letters. Here are the most popular options:

— SN (subnormal). Models for a cool temperate climate have an operating range from +10 °C to + 32 °C. Such a unit can be useful in a poorly heated room where the temperature can drop below +16 °C — for example, on the veranda of a private house, in a garage, etc.

— N (normal). Freezer for a temperate climate, with an operating temperature range of +16...+32 °C. Such a unit is suitable for most residential apartments and houses in mid-latitudes.

— ST (subtropical). Models for subtropical and humid tropical climates. Normally they work at the range of external temperatures +18...+38 °C.

— T (tropical). Refrigerators for dry tropical climates. Designed for temperature range +18 °C to +43 °C.

Also, note that there are many models on the market with an extended temperature range covering several classes. For example, a unit labelled N-ST will have a temperature range of +16...+38 °C. These freezers are indispensable in climates, conditions which are not covered by one standard class — for example, in cold winters and hot summers.
Liebherr SIGN 3566 often compared
Liebherr SIGN 3556 often compared