Dark mode
USA
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Boilers

Comparison ATON Compact 16EB 16 kW vs ATON Compact 16E 16 kW

Add to comparison
ATON Compact 16EB 16 kW
ATON Compact 16E 16 kW
ATON Compact 16EB 16 kWATON Compact 16E 16 kW
from $287.80 up to $343.22
Outdated Product
from $267.40 up to $315.62
Outdated Product
TOP sellers
Energy sourcegasgas
Installationparapetparapet
Typedual-circuit (heating and DHW)single-circuit (heating only)
Heating area120 m²120 m²
Technical specs
Heat output16 kW16 kW
Power supplyautonomous (no electricity)autonomous (no electricity)
Coolant max. T90 °С90 °С
Heating circuit max. pressure1.5 bar1.5 bar
DHW circuit max. pressure6 bar
Consumer specs
Circulation pump
Boiler specs
Efficiency90 %90 %
Combustion chamberclosed (turbocharged)closed (turbocharged)
Flue diameter60/100 mm60/100 mm
Inlet gas pressure13 mbar13 mbar
Max. gas consumption1.8 m³/h1.8 m³/h
Connections
Mains water intake1/2"
DHW flow1/2"
Gas supply1/2"1/2"
Central heating flow1 1/2"1 1/2"
Central heating return1 1/2"1 1/2"
Safety
Safety systems
gas pressure drop
water overheating
flame loss
gas pressure drop
water overheating
flame loss
More specs
Dimensions (HxWxD)700х275х800 mm700х275х800 mm
Weight64 kg61 kg
Added to E-Catalogmarch 2012march 2012

Type

Depending on the set of functions, boilers are divided into single-circuit and dual-circuit.

- Single-circuit boilers are equipped with one heat exchanger, in which the heat from fuel combustion is transferred to the heat medium of the heating system. The only function of such boilers is space heating. It is technically possible to use single-circuit boilers to provide hot water, but this requires an additional tank (the so-called indirect water heater).

- In dual-circuit boilers, the primary heat exchanger is supplemented by a secondary one. Due to this, such a boiler, in addition to heating the room, also provides a hot water supply. In this case, both running water and water accumulated in a special tank(see Built-in water heater tank) can be used.

DHW circuit max. pressure

The maximum pressure in the hot water circuit (DHW) at which it can operate for a long time without failures and damage. See "Heating circuit maximum pressure".

Mains water intake

The diameter of the pipe for connecting the pipe through which cold water is supplied to the boiler for heating and use in the hot water supply system.

Diameters are indicated in inches. It is allowed to connect a pipe of a different diameter through an adapter, but the best option is still a match in size. There are connection options 1/2", 3/4", 1" and 1 1/2".

DHW flow

The diameter of the pipe for connecting the pipe through which hot water leaves the boiler for the DHW system.

Diameters are indicated in inches. It is allowed to connect a pipe of a different diameter through an adapter, but the best option is still a match in size.
ATON Compact 16E often compared