Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   Portable Power Stations

Comparison Allpowers R1500 vs Jackery Explorer 1000 Plus

Add to comparison
Allpowers R1500
Jackery Explorer 1000 Plus
Allpowers R1500Jackery Explorer 1000 Plus
Outdated Product
from $699.00 
Expecting restock
TOP sellers
2 USB A ports, 2 USB-C ports. LiFePO4 – Lithium Iron Phosphate Battery. Surges up to 4000 W are allowed.
In boxcharging stationcharging station
Rated power1800 W2000 W
Peak power3000 W4000 W
Output waveformsinusoid (PSW)sinusoid (PSW)
UPS function
Switchover time to battery15 ms
Outputs
Sockets (230 V)42
USB-A (quick charge)
2
5В/3A, 9В/2A, 12В/1.5A
18 W
2
5В/3A, 9В/2A, 12В/1.5A
18 W
USB-C
2 pcs
3 A, 5 A
100 W
2 pcs
3 A, 5 A
100 W
Wireless charging2 zones 15 W
Car cigarette lighter
Inputs (station charging)
From solar panels
Input port XT60
Battery and charging time
Connecting an additional battery
Battery typeLiFePO4LiFePO4
Battery capacity1152 Wh1264.64 Wh
Charging cycles35004000
Charging time (socket) 48 min100 min
Charging time (solar panel) 108 min120 min
Charging time (cigarette lighter) 870 min
Charging power (socket)1500 W
Charging power (solar panel)650 W800 W
Charging power (socket + solar panel)1500 W
General
Smartphone synchronizationBluetooth and WiFiBluetooth and WiFi
PSUbuilt into the bodybuilt into the body
Display
Backlight
Carrying handle
Operating temperature0 °C ~ +40 °C0 °C ~ +45 °C
Dimensions (LxWxH)413x265x312 mm356x260x283 mm
Weight16.7 kg14.5 kg
Added to E-Catalogjuly 2024january 2024
Compare Allpowers R1500 and Jackery Explorer 1000 Plus
Allpowers R1500 often compared
Jackery Explorer 1000 Plus often compared
Glossary

Rated power

Power that a device can consistently produce for an indefinitely long time without any unpleasant consequences. For normal operation of the charging station, the rated power must be at least 15 - 20% higher than the total power of all devices simultaneously connected to it.

Peak power

Some electrical appliances (in particular, units with electric motors - refrigerators, air conditioners, etc.) consume significantly more energy at startup than after reaching the operating mode. For such a load, the peak power of the charging station must be taken into account - its indicator must be higher than the starting power of the load.

UPS function

Charging stations with UPS function switch consumers to backup power from their own battery, acting as an uninterruptible power supply. In comparison with full-fledged UPSs, switching does not occur instantly, but with a certain delay (about 10-30 ms). To use this function correctly, you must first study the instructions for the charging station, which often describes the correct procedure for connecting the intended consumer devices.

Switchover time to battery

The delay (usually in milliseconds) between the power going out from the outlet and the moment when the station starts feeding connected devices from its battery, maintaining "pass-through" power. The shorter this time, the higher the chance that devices won't notice the drop at all: for routers, cameras, NAS, and PCs, this is critical because a long pause can cause a reboot, loss of connection, or even filesystem errors. Essentially, this is the same parameter as in a classic UPS, but for charging stations, it greatly depends on implementation: models with a more "UPS-like" switching scheme switch considerably faster, while some stations formally have a UPS mode but actually create a noticeable break or activate the output only after "realizing" the network's loss. In practice, this point helps distinguish a charging station that is truly suitable as a UPS for sensitive electronics from an option "for lights and charging": for example, for home internet and video surveillance, minimal switching time is important, while for lamps, charging phones, or a heater, a brief pause is typically not critical.

Sockets (230 V)

Total number of outlets with output voltage. This is, in fact, the number of devices that can be simultaneously connected to the charging station without the use of splitters, extension cords and carriers. Accordingly, weaker charging stations have one or two sockets in their submission. Powerful charging stations already have three or more sockets “on board”.

Wireless charging

In wireless charging mode, energy is transferred to the gadget being charged through an inductive surface, which is usually built into the upper plane of the charging station case. There can be one slot for wireless charging or several of them are provided. The range of this technology does not exceed a few centimeters. However, this method of charging eliminates the fuss with wires and reduces wear on the connectors. One of the key disadvantages of this format is considered to be low power and, accordingly, slow charging speed.

Input port XT60

Power connector with two round connectors, used to replenish energy reserves in the battery cells of the charging station. For the most part, the input port of the XT60 is for charging the device from solar panels using the appropriate cable.

Battery capacity

Nominal battery capacity, in fact - the amount of energy that is supposed to be stored. The larger it is, the longer the battery life of the charging station will be, all other things being equal. On the other hand, this parameter also affects the dimensions, weight and price of the battery, despite the fact that an energy-intensive battery is not always required. By the indicator of capacity in watt-hours, you can compare batteries with each other.

Charging cycles

The number of charge-discharge cycles that the battery can withstand without significant loss of performance.

In the process of operation, the batteries wear out, which causes their performance to suffer (in the first place, the capacity decreases). Battery life is usually measured in charge-discharge cycles. However, models with the same declared resource are not always equally durable in practice. Different manufacturers may interpret “significant loss of performance” in different ways: for example, one brand indicates the resource up to a 20% decrease in capacity (DOD > 80%), another - up to a 60% decrease (DOD > 40%) Behind the abbreviation DOD worth decoding Depth of Discharge, i.e. discharge depth. Therefore, when choosing, it makes sense to focus not only on pure numbers, but also on other sources - test results, reviews, etc. Also note that battery life can be noticeably reduced if the operating conditions are violated (for example, in case of overheating or hypothermia).