Catalog   /   Tools & Gardening   /   Measuring tools   /   Multimeters

Comparison UNI-T UT131A vs UNI-T UT33A+

Add to comparison
UNI-T UT131A
UNI-T UT33A+
UNI-T UT131AUNI-T UT33A+
Compare prices 1Outdated Product
TOP sellers
Product typemultimetermultimeter
Typedigitaldigital
Measurement types
Measurements
voltage
current
resistance
capacity
voltage
current
resistance
capacity
Specs
Current typeAC / DCAC / DC
Voltage typeAC / DCAC / DC
DC voltage minimum200 mV200 mV
DC voltage max.250 В600 В
Measurement accuracy (V⁻)0.5 %0.5 %
AC voltage minimum200 mV200 mV
AC voltage max.250 В600 В
DC minimum200 µA200 µA
DC max.10 А10 А
AC minimum200 µA200 µA
AC max.10 А10 А
Impedance minimum200 Ω200 Ω
Impedance max.200 MΩ200 MΩ
Display size66x51 mm48x16 mm
Display count19991999
Display value3 1/23 1/2
Features
Functions
diode test
continuity test mode
autoranging
diode test
continuity test mode
autoranging
In box
battery
test probes
battery
test probes
General
Display backlight
Stand
Power sourcebatterybattery
Battery type2xAAA2xAAA
Dimensions134x77x47 mm134x77x47 mm
Weight206 g206 g
Added to E-Catalogmay 2021may 2021
Compare UNI-T UT131A and UT33A+
Price comparison
UNI-T UT131A often compared
UNI-T UT33A+ often compared
Glossary

DC voltage max.

The highest DC voltage (see “Voltage type”) that can be effectively measured with this instrument.

Compliance with this parameter is important not only for correct measurements, but also from a safety point of view. Measuring too high voltage can lead to malfunctions of the device, ranging from the operation of emergency protection (and it can take the form of a disposable fuse that requires replacement after operation) and ending with a complete failure and even fire. Therefore, it is impossible to exceed this indicator anyway. Yes, and choosing a device for maximum voltage is worth with a certain margin — at least 10 – 15%: this will give an additional guarantee in case of emergency situations. On the other hand, the margin should not be too large: a high constant voltage threshold can degrade the accuracy of measurements at low voltage, as well as affect the price, dimensions and weight of the device.

Note that most multimeters and other similar devices have several measurement ranges, with different maximum thresholds. So, for a safe measurement of voltage close to the maximum, you need to set the appropriate mode in the settings.

AC voltage max.

The largest alternating voltage (see “Type of voltage”) that can be effectively measured using this model. This parameter is important not only for measurements as such, but also for safe handling of the device: measuring too high voltage will, at best, trigger emergency protection (and it is possible that after that you will have to look for a new fuse to replace the burned one), at worst — to equipment failure or even fire. In addition, for safe measurements, a voltage margin is highly desirable — this is due both to the characteristics of the alternating current and to the possibility of various emergency situations in the network, primarily voltage surges. For example, for 230 V networks, it is desirable to have a device for at least 250 V, and preferably 300 – 310 V; detailed recommendations for other cases can be found in special sources.

Note that most multimeters and other similar devices have several measurement ranges, with different maximum thresholds. So, for a safe measurement of voltage close to the maximum, you need to set the appropriate mode in the settings.

Stand

The presence of a stand in the design of the device.

Such a stand, usually, is a folding plate or frame in the lower part of the case. In the open state, it allows you to install the device at an angle to the surface on which it lies — this position is often more convenient than strictly horizontal.