Add to comparison | ![]() |
|---|---|
| Marstek Venus A | |
from $572.37 up to $864.45 | |
| TOP sellers | |
Home energy independence system with capacity expansion up to 12.72 kWh. Operates on a Plug & Play principle. Smart energy management with Marstek Intelligence technology. | |
| Device type | hybrid inverter |
| In box | inverter only |
| Network type | 1 phase (230 V) |
AC output | |
| Rated power | 1.2 kVA |
| Rated AC current | 5.22 A |
| Output waveform | pure sine |
| Number of sockets | 1 |
Batteries and DC charging | |
| Connection voltage | 41.6 В |
| Total battery capacity | 2120 Wh |
Solar PV panels | |
| Max. power | 2.4 kW |
| Operating voltage PV | 16 – 60 В |
| Short circuit current | 20 А |
| Controller | 4xMMPT |
Features and control | |
| Functions | UPS function built-in monitoring |
| Control interfaces | Bluetooth Wi-Fi LAN (RJ45) |
| Protection | short circuit protection ↑ or ↓ battery voltage protection overload protection overheat protection |
General | |
| Display | in absent |
| Cooling | passive |
| Noise level | 30 dB |
| Casing protection class | IP65 |
| Operating temperature | -20 °C ~ +60 °C |
| Dimensions (HxWxD) | 220x450x340 mm |
| Weight | 26 kg |
| Added to E-Catalog | february 2026 |
You may be interested in
My comparisons
Glossary
Device type
— Autonomous inverter. Voltage and power converters that are not connected to an external electrical network. They are supposed to be used as part of autonomous photovoltaic systems - such inverters generate electricity, which is spent exclusively for the needs of the household. It can be consumed directly by household appliances or accumulated in batteries. This type of inverter is often called off grid.
— Network inverter. Inverters operating synchronously with the external power supply network. They are designed to convert solar energy into alternating power with the parameters of the general network. Grid-connected inverters are used in battery-free systems - all generated energy is used for own consumption, and the excess is transferred to the network at a “feed-in tariff”. To do this, some indicators of generated electricity are adjusted, in particular, amplitude differences are eliminated, the network frequency is equalized, etc. Grid-tied inverters are also known as on-grid inverters.
— Hybrid inverter. Battery-grid inverters are peculiar hybrids of autonomous and network converters. Actually, this is where the name hybrid comes from. Inverters of this type work with battery chains, and excess electricity is sent to the general network. This ensures the energy independence of the system based on solar panels with the ability to use the energy a...ccumulated in the batteries without disconnecting from the network. For example, if DC power is prioritized, power is primarily supplied from batteries, and any energy shortages are supplied from the external grid. This comes in handy in case of bad weather conditions or insufficient power generated by solar panels. If electricity is generated in excess, the excess energy is released into the general network at a “feed-in tariff”.
— Inverter for campers (motorhomes). Such narrow-niche inverters usually work in conjunction with a branded charging station - while staying at a campsite, it charges the vehicle’s battery. And while driving, such inverters are connected to the car’s alternating power generator and with their help, the energy reserves in the battery cells of the charging station are replenished.
— Network inverter. Inverters operating synchronously with the external power supply network. They are designed to convert solar energy into alternating power with the parameters of the general network. Grid-connected inverters are used in battery-free systems - all generated energy is used for own consumption, and the excess is transferred to the network at a “feed-in tariff”. To do this, some indicators of generated electricity are adjusted, in particular, amplitude differences are eliminated, the network frequency is equalized, etc. Grid-tied inverters are also known as on-grid inverters.
— Hybrid inverter. Battery-grid inverters are peculiar hybrids of autonomous and network converters. Actually, this is where the name hybrid comes from. Inverters of this type work with battery chains, and excess electricity is sent to the general network. This ensures the energy independence of the system based on solar panels with the ability to use the energy a...ccumulated in the batteries without disconnecting from the network. For example, if DC power is prioritized, power is primarily supplied from batteries, and any energy shortages are supplied from the external grid. This comes in handy in case of bad weather conditions or insufficient power generated by solar panels. If electricity is generated in excess, the excess energy is released into the general network at a “feed-in tariff”.
— Inverter for campers (motorhomes). Such narrow-niche inverters usually work in conjunction with a branded charging station - while staying at a campsite, it charges the vehicle’s battery. And while driving, such inverters are connected to the car’s alternating power generator and with their help, the energy reserves in the battery cells of the charging station are replenished.
In box
— Only the inverter. This configuration means that in the box you receive the device itself without additional modules. This option is chosen when the system is already assembled and you need to replace or scale a unit, or when the designer intentionally selects external accessories for specific tasks and brands. The advantage is the minimal price and freedom of configuration; the drawback is the need to purchase everything for startup and monitoring.
— With battery module. This set provides guaranteed compatibility and factory warranty on the combination, however, it is more expensive. The only potential hurdle is the standard battery volume, which may be insufficient for certain needs. However, nothing prevents you from purchasing additional batteries.
— With battery module. This set provides guaranteed compatibility and factory warranty on the combination, however, it is more expensive. The only potential hurdle is the standard battery volume, which may be insufficient for certain needs. However, nothing prevents you from purchasing additional batteries.
Network type
— Single-phase (230 V). Single-phase power is well known from classic 230 V household sockets. However, this also often includes models for other alternating voltage values - for example, 110 V.
— Three-phase (400 V). Three-phase power supply with a voltage of 400 V is used mainly for energy-hungry devices for which 230 V networks do not provide enough power. This option can be used both for private households and in the industrial sector.
— Single-phase / three-phase. Models with the ability to connect to both single-phase power supply at 230 V and three-phase power supply at 400 V. This allows them to be used with both household and industrial networks - depending on which option is more convenient at the moment.
— DC (constant voltage). This category usually includes a few inverters for campers (motorhomes) (see “Device Type”). They are designed for operation in automotive networks with a constant voltage of 12/24 V.
— Three-phase (400 V). Three-phase power supply with a voltage of 400 V is used mainly for energy-hungry devices for which 230 V networks do not provide enough power. This option can be used both for private households and in the industrial sector.
— Single-phase / three-phase. Models with the ability to connect to both single-phase power supply at 230 V and three-phase power supply at 400 V. This allows them to be used with both household and industrial networks - depending on which option is more convenient at the moment.
— DC (constant voltage). This category usually includes a few inverters for campers (motorhomes) (see “Device Type”). They are designed for operation in automotive networks with a constant voltage of 12/24 V.
Rated power
The nominal power in kVA shows the total electrical load that an inverter can handle in terms of voltage and current, taking into account the characteristics of the connected devices. This parameter is especially important for equipment with motors, transformers, compressors, and other reactive loads, where consumption does not always equal useful power in kW.
kVA should not be directly equated to kW: at a power factor of 0.8, a 5 kVA device is actually designed for approximately 4 kW of active load. For example, a pump, air conditioner, or refrigeration compressor may load the inverter more in kVA terms than it seems based on their usual power in watts.
kVA should not be directly equated to kW: at a power factor of 0.8, a 5 kVA device is actually designed for approximately 4 kW of active load. For example, a pump, air conditioner, or refrigeration compressor may load the inverter more in kVA terms than it seems based on their usual power in watts.
Rated AC current
The current strength that the device is capable of stably and safely delivering when operating in rated mode (i.e. for the longest possible time without the risk of overloads and failures). The indicator is expressed in Amperes (A).
Output waveform
The form that the graph of the voltage produced by the inverter has.
This can be a pure sinusoid with a high quality output signal - the voltage on the graph changes evenly, without sudden jumps and drops. It is as close as possible to the parameters of conventional sockets. Models with pure sine wave voltage allow you to connect almost any load - even delicate electronics that are sensitive to power quality. On the other hand, such quality requires the use of complex control circuits and significantly affects the cost of the inverter, and there is not always a real need for it.
Another option for the output signal shape is a modified (approximated) sine wave. As a rule, such graphs are constructed from stepped lines, sometimes quite large. The disadvantage of the modified sine is the inability to work with sensitive equipment (for example, where asynchronous motors or transformers are installed). However, in the absence of such a need, this moment cannot be called critical.
This can be a pure sinusoid with a high quality output signal - the voltage on the graph changes evenly, without sudden jumps and drops. It is as close as possible to the parameters of conventional sockets. Models with pure sine wave voltage allow you to connect almost any load - even delicate electronics that are sensitive to power quality. On the other hand, such quality requires the use of complex control circuits and significantly affects the cost of the inverter, and there is not always a real need for it.
Another option for the output signal shape is a modified (approximated) sine wave. As a rule, such graphs are constructed from stepped lines, sometimes quite large. The disadvantage of the modified sine is the inability to work with sensitive equipment (for example, where asynchronous motors or transformers are installed). However, in the absence of such a need, this moment cannot be called critical.
Number of sockets
The number of standard 230 V sockets provided in the inverter design.
The more sockets there are, the more electrical appliances can be connected to the inverter at once. At the same time, the specificity of using inverters is such that they rarely have to be used for several devices at once. In addition, simultaneous connection requires appropriate power (see “Rated output power”), and the sockets themselves also significantly affect the dimensions. Therefore, most often in modern home inverters one socket is used – this, usually, is enough. However, high-quality powerful inverters can have two sockets.
The more sockets there are, the more electrical appliances can be connected to the inverter at once. At the same time, the specificity of using inverters is such that they rarely have to be used for several devices at once. In addition, simultaneous connection requires appropriate power (see “Rated output power”), and the sockets themselves also significantly affect the dimensions. Therefore, most often in modern home inverters one socket is used – this, usually, is enough. However, high-quality powerful inverters can have two sockets.
Connection voltage
The efficiency of the solar system, laid down by the manufacturer of the inverter, directly depends on this parameter. The following battery voltage options are most widely used: 12 V, 24 V and 48 V.
Total battery capacity
The total capacity of the connected batteries in watt-hours (Wh). In fact, this is the amount of energy that is supposed to be stored in the battery. The larger the capacity, the longer the battery life of the connected equipment will be, all other things being equal. On the other hand, this parameter also affects the dimensions, weight and price of the battery. Based on the capacity in watt-hours, batteries can be compared with each other.