Catalog   /   Climate, Heating, Water Heating   /   Heating & Cooling   /   Recuperators & Ventilation Recovery

Comparison VENTS Breezy 200-E vs VENTS Breezy 160-E Smart

Add to comparison
VENTS Breezy 200-E
VENTS Breezy 160-E Smart
VENTS Breezy 200-EVENTS Breezy 160-E Smart
Outdated ProductOutdated Product
TOP sellers
System typedecentralizeddecentralized
Ventilation typesupply and exhaustsupply and exhaust
Mountingsuspendedsuspended
Mounting diameter200 mm160 mm
Specs
Features
heater
heater
Air filtersG3G3
CO₂ carbon dioxide sensor
Air pollution sensor
Minimum air flow (ventilation)15 m³/h15 m³/h
Maximum air flow (ventilation)70 m³/h57 m³/h
Minimum air flow (recuperation)15 m³/h15 m³/h
Maximum air flow (recuperation)70 m³/h57 m³/h
Number of fan speeds33
Minimum noise level25 dB25 dB
Maximum noise level55 dB55 dB
Type of heat exchangerplateplate
Heat exchanger materialcoppercopper
Heat exchanger efficiency85 %88 %
Heater typeelectric heaterelectric heater
Heater power100 W100 W
Minimum operating temperature-30 °C-30 °C
General specs
Remote control
Control via Internet
Display
EC fan
Power consumption in ventilation mode22 W22 W
Power consumption (reheater + ventilation)122 W122 W
Mains voltage230 В230 В
Minimum wall thickness240 mm240 mm
Maximum wall thickness447 mm440 mm
Decorative panel thickness45 mm45 mm
Country of originUkraineUkraine
Dimensions307x245x553 mm307x245x540 mm
Added to E-Catalogapril 2025april 2025
Compare VENTS Breezy 200-E and Breezy 160-E Smart
VENTS Breezy 160-E Smart often compared
Glossary

Mounting diameter

The diameter of the holes intended for connecting air ducts to the ventilation unit. The more performant the air ventilation unit, the more air the ducts must pass and the larger, usually, the mounting holes. For wall-mounted models (see above), this parameter determines the size of the channel that must be drilled into the wall to accommodate the unit.

Maximum air flow (ventilation)

The highest performance of the air ventilation unit; or, if the air flow control is not provided for in the design, the nominal capacity of the unit.

In this case, air flow refers to the amount of air that the unit can pass through itself per hour. The optimal air flow value for each room is calculated by the formula "room volume multiplied by the air exchange rate"; the air flow must not be lower than this indicator; otherwise, we cannot talk about effective ventilation. The volume is easy to calculate by multiplying the area of the room by the height of the ceilings, and the multiplicity indicates how many times per hour the air in the ventilated space should be updated. It depends on the type and purpose of the room: for example, a multiplicity of 1 is enough for a residential apartment, and at least 4 is required for a pool (there are special tables by which you can determine the multiplicity for each type of room). Thus, for example, for an apartment with a living area of 70 m², a ceiling height of 2.5 m and a kitchen of 9 m² (air exchange rate of at least 2), a duct of at least 70*2.5*1+9*2.5*2=220 m³ (excluding bathroom and toilet, they have their requirements for multiplicity).

It should be noted that a certain flow margin (about 10–15%) will not be superfluous, but it hardly makes sense to chase higher rates — after all, performance requires appropriate power, which, in turn, affects the dimensions, price and...energy consumption of the installation.

Heat exchanger efficiency

Efficiency of the heat exchanger used in the heat exchanger of the supply and exhaust system (see "Features").

Efficiency is defined as the ratio of useful work to the energy expended. In this case, this parameter indicates how much heat taken from the exhaust air, the heat exchanger transfers to the supply air. The efficiency is calculated by the ratio between the temperature differences: you need to determine the difference between the outdoor air and the supply air after the heat exchanger, the difference between the outdoor and exhaust air, and divide the first number by the second. For example, if at an outside temperature of 0 °С, the temperature in the room is 25 °С, and the heat exchanger produces air with a temperature of 20 °С, then the efficiency of the heat exchanger will be (25 – 0)/(20 – 0)= 25/20 = 80%. Accordingly, knowing the efficiency, it is possible to estimate the temperature at the outlet of the heat exchanger: the temperature difference between the inside and outside must be multiplied by the efficiency and then the resulting number is added to the outside temperature. For example, for the same 80% at an outdoor temperature of -10 °C and an internal temperature of 20 °C, the inflow temperature after the heat exchanger will be (20 – -10)*0.8 + -10 = 30*0.8– 10 = 24 – 10 = 14 °C.

The higher the efficiency, the more heat will be returned to the room and the more savings on heating will be. At the same time, a highly efficient heat e...xchanger is usually expensive. Also note that the efficiency may vary slightly for certain values of the external and internal temperatures, while manufacturers tend to indicate the maximum value of this parameter — accordingly, in fact, it may turn out to be lower than the claimed one.

Control via Internet

Ability to control device via the Internet. The connection of the unit to the World Wide Web, usually, is carried out via Wi-Fi, and the control format may be different: in some models, you need to use a special application installed on your smartphone or tablet; in others, it is enough to open a special page in a browser. Anyway, this function allows you to control the device from anywhere in the world where there is Internet access, as well as, monitor its status and receive notifications about various operating parameters (current power, outdoor temperature, failures and malfunctions, etc.).

Maximum wall thickness

The maximum thickness of the wall on which the air ventilation unit can be hung with the possibility of wall mounting (see "Mounting").

This parameter is indicated for models mounted directly into a hole in the wall — see "Mounting" for details. The installation length (the length of the pipe between the trims) can usually be adjusted to suit specific wall thicknesses. However, if the wall thickness is too large, the pipe simply will not reach the outside, and installation will be impossible. Therefore, you need to pay close attention to this parameter — especially when it comes to buildings with thick walls, for example, old houses.